Monika Żuchowska

Mrs. Monika Żuchowska

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
PAWEŁ MARĆPAWEŁ MARĆ
PAWEŁ MARĆ
MŻMonika Żuchowska
Monika Żuchowska
IJIwona Jakubowska
Iwona Jakubowska
Jaroszewicz R. LeszekJaroszewicz R. Leszek
Jaroszewicz R. Leszek
Polymer microtips are 3D microstructures manufactured on the end face of an optical fiber by using the photopolymerization process. Such micro-optic elements made on a multi-mode optical fiber were previously tested as a transducer of refractive index sensor. These studies were an inspiration to investigate the possibility of using this type of transducer to measure the presence of volatile organic compounds in the air. The experimental results of microtips polymerized with UV and VIS were reported. It was possible to detect the presence of five different volatile compounds in the air due to the sensitivity of the transducer to the refractive indices changes. These changes were induced by the vapors condensed on the microtip surface. The measured time responses have shown that the return loss decreases rapidly as the microtip is inserted inside a glass vial filled with the tested compound. Moreover, correlations between calculated dynamic ranges and refractive indices and volumes of the volatile compounds inside the vials were negligible. Therefore, this type of sensor can be categorized as a condensed material threshold sensor. This sensor can be used in warning systems for monitoring leakages of pipelines carrying volatile chemicals.

10 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
AKAleksandra Kalbarczyk
Aleksandra Kalbarczyk
Jaroszewicz R. LeszekJaroszewicz R. Leszek
Jaroszewicz R. Leszek
NBNoureddine Bennis
Noureddine Bennis
MŻMonika Żuchowska
Monika Żuchowska
PAWEŁ MARĆPAWEŁ MARĆ
PAWEŁ MARĆ
This article proposes an interferometric method for a variable depolarizer characterization with features that distinguish it from the polarimetric system. Information about the behavior of a vertically aligned nematic cell as a variable depolarizer can be extracted from Young interferometer measurements in real time. These results could be significant for understanding the polarization phenomena in depolarizing media such as biological tissue.

5 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
PAWEŁ MARĆPAWEŁ MARĆ
PAWEŁ MARĆ
MŻMonika Żuchowska
Monika Żuchowska
Jaroszewicz R. LeszekJaroszewicz R. Leszek
Jaroszewicz R. Leszek
A polymer microtip manufactured at the end of a multi-mode optical fiber by using the photopolymerization process offers good reflective properties, therefore, it is applicable as an optical fiber sensor micro-transducer. The reflective properties of this microelement depend on the monomer mixture used, optical fiber type, and light source initiating polymerization. Experimental results have shown that a proper selection of these parameters has allowed the design of a new class of sensing structure which is sensitive to the refractive index (RI) changes of a liquid medium surrounding the microtip. An optical backscatter reflectometer was applied to test a group of micro-transducers. They were manufactured from two monomer mixtures on three different types of multi-mode optical fibers. They were polymerized by means of three optical light sources. Selected micro-transducers with optimal geometries were immersed in reference liquids with a known RI within the range of 1.3–1.7. For a few sensors, the linear dependences of return loss and RI have been found. The highest sensitivity was of around 208 dB/RIU with dynamic 32 dB within the range of 1.35–1.48. Sensing characteristics have minima close to RI of a polymer microelement, therefore, changing its RI can give the possibility to tune sensing properties of this type of sensor.

16 January 2020 in Materials
Verified
Journal Article
Open access
PDF file
MŻMonika Żuchowska
Monika Żuchowska
PAWEŁ MARĆPAWEŁ MARĆ
PAWEŁ MARĆ
IJIwona Jakubowska
Iwona Jakubowska
Jaroszewicz R. LeszekJaroszewicz R. Leszek
Jaroszewicz R. Leszek
The technology of polymer microtips’ manufacturing on the ends of selected multi-mode fibers has been reported. The study’s key element was an extended description of technology parameters’ influence on the shape of these 3D microstructures. Basic technology parameters such as spectral characteristics of the light source, monomer mixture type, optical power, and exposure time were taken under consideration. Depending on those parameters, different shapes, sizes, and surface structures of microtips were obtained. The spectral characteristics of the light and optical power delivered to a monomer drop were identified as the most important parameters for the formation of the desired 3D shape of the microtip. Presented experimental results are the base for further studies directed to the application of these micro-elements in the fields of optical measurements and sensors’ technology.

31 August 2022 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
MŻMonika Żuchowska
Monika Żuchowska
PAWEŁ MARĆPAWEŁ MARĆ
PAWEŁ MARĆ
IJIwona Jakubowska
Iwona Jakubowska
Jaroszewicz R. LeszekJaroszewicz R. Leszek
Jaroszewicz R. Leszek
The development of optical fiber sensor technology has led to interest in the use of new elements for functionalizing the fiber end face. The modification of this part of the fiber can be conducted by forming a polymer microtip (PM). The technology of manufacturing PMs on single-mode and multi-mode fibers is widely described in the literature. Geometry and optical properties of PMs depend on technological process parameters, optical fiber type, and monomer mixture composition. PM can be considered in the context of sensor applications as a transducer that is sensitive to refractive index (RI) changes. RI sensors were an inspiration to explore the possibility of using PM to detect VOCs in air. Five selected volatile compounds were tested: trimethyl phosphate (TMP), 1,4-thioxane (THX), acetone, toluene, and aqueous ammonia. The principle of the sensor operation was based on the phenomenon of attraction and repulsion of the condensed VOCs. Attracted VOC molecules cover the PM surface and form a liquid film that changes the RI at the interface between the PM and the external material. The return loss level changes rapidly when the PM is introduced into the glass vial filled with the test compound. The proposed sensor acts as a threshold, showing only the presence of condensed VOC, but with no ability to determine its concentration and type of substance. Such a sensor can be used in warning systems to monitor leaks in volatile chemical transport lines, as well as to monitor accumulations of hazardous liquid substances that easily transit into the vapor phase. It acts as an early warning system in the event of the condensation process of the monitored dangerous chemical agent.

1 October 2024 in Acta Physica Polonica A
Verified
Journal Article
Open access
PDF file
MŻMonika Żuchowska
Monika Żuchowska
Polymer microtips fabricated at the ends of multi-mode optical fibers can act as refractive index sensor transducers and as lenses. The aim of the studies was to test the possibility of improving the refractive index sensor sensitivity by adding gold nanoparticles (concentrations of 1\% and 5%) and titanium dioxide (concentrations of 5% and 16.67%) to the monomer mixture. The presence of a nanoparticle composite in the mixture creates strongly scattering centers, which results in reduced reflected signal levels and a lower value of return losses. Shifts in return loss minima for the refractive index sensors were observed. After a microtip was manufactured from UV-cured pentaerythritol triacrylate mixture on multi-mode fiber with a 105 nm core diameter, the minimum reached a refractive index value of 1.44, while when Au 1% and Au 5% composites were added, the minimum shifted to 1.48. Doping the mixture with a 1% Au composite resulted in improved transmission properties in the 600−1200 nm spectral range. An improvement in transmission in the infrared range was obtained for a microtip doped with 16.67% TiO2. Doping with titanium dioxide resulted in a significant decrease in signal in the wavelength range below 1200 nm.