Qamar Abbas

Dr. Qamar Abbas

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2015 in Electrochemistry Communications
Verified
Journal Article
Closed access
ALA. Laheäär
A. Laheäär
PPP. Przygocki
P. Przygocki
QAQamar Abbas
Qamar Abbas
FBF. Béguin
F. Béguin

1 March 2013 in Journal of Energy Chemistry
Verified
Journal Article
Closed access
EFElzbieta Frackowiak
Elzbieta Frackowiak
QAQamar Abbas
Qamar Abbas
FBFrançois Béguin
François Béguin

1 September 2014 in Electrochimica Acta
Verified
Journal Article
Closed access
QAQamar Abbas
Qamar Abbas
DPDorota Pajak
Dorota Pajak
EFElżbieta Frąckowiak
Elżbieta Frąckowiak
FBFrançois Béguin
François Béguin


1 June 2014 in Electrochimica Acta
Verified
Journal Article
Closed access
PRPaula Ratajczak
Paula Ratajczak
KJKrzysztof Jurewicz
Krzysztof Jurewicz
PSPiotr Skowron
Piotr Skowron
QAQamar Abbas
Qamar Abbas
FBFrançois Béguin
François Béguin

23 January 2015 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
QAQamar Abbas
Qamar Abbas
PRP. Ratajczak
P. Ratajczak
PBP. Babuchowska
P. Babuchowska
ACA. Le Comte
A. Le Comte
DBD. Bélanger
D. Bélanger
FBF. Béguin
F. Béguin
Strategies are presented to enhance operating potential and cycle life of AC/AC capacitors using salt aqueous electrolytes. Li2SO4 (pH = 6.5) allows 99% efficiency to be exhibited at 1.6 V cell potential with low self-discharge, while in BeSO4 (pH = 2.1) efficiency is low (81%). Li2SO4 performs better due to high di-hydrogen over-potential at the negative electrode and related pH increase in AC porosity. When stainless steel current collectors are used in Li2SO4, the cell resistance suddenly increases after 12 hours floating at 1.6 V, due to corrosion of the positive collector. With nickel negative and stainless steel positive collectors, the electrode potentials are shifted by −105 mV at cell potential of 1.6 V, allowing stable cell parameters (capacitance, resistance) and reduction of corrosion products formation on positive steel collector after 120 hours floating. Phenanthrenequinone was grafted on activated carbon to get an additional faradaic contribution in buffer solutions (pH = 4.0 or 7.2). The three-electrode cell CVs show that the redox peaks of the phenanthrenequinone graft shift toward negative values when pH increases from 4 to 7.2. The grafted carbon displays a capacitance value of 194 F g−1 at pH = 4.0 as compared to 82 F g−1 for the as-received carbon.