Lorainne Conroy

Dr. Lorainne Conroy


Research Focus & Metrics

Academic Career Length

38Years (1989-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2013 in Occupational and Environmental Medicine
Verified
Journal Article
Closed access
PDF file
JGJudith Graber
Judith Graber
LSLeslie T Stayner
Leslie T Stayner
RCRobert A Cohen
Robert A Cohen
LCLorainne Conroy
Lorainne Conroy
MAMichael D Attfield
Michael D Attfield
Objectives To evaluate respiratory related mortality among underground coal miners after 37 years of follow-up. Methods Underlying cause of death for 9033 underground coal miners from 31 US mines enrolled between 1969 and 1971 was evaluated with life table analysis. Cox proportional hazards models were fitted to evaluate the exposure-response relationships between cumulative exposure to coal mine dust and respirable silica and mortality from pneumoconiosis, chronic obstructive pulmonary disease (COPD) and lung cancer. Results Excess mortality was observed for pneumoconiosis (SMR=79.70, 95% CI 72.1 to 87.67), COPD (SMR=1.11, 95% CI 0.99 to 1.24) and lung cancer (SMR=1.08; 95% CI 1.00 to 1.18). Coal mine dust exposure increased risk for mortality from pneumoconiosis and COPD. Mortality from COPD was significantly elevated among ever smokers and former smokers (HR=1.84, 95% CI 1.05 to 3.22; HRK=1.52, 95% CI 0.98 to 2.34, respectively) but not current smokers (HR=0.99, 95% CI 0.76 to 1.28). Respirable silica was positively associated with mortality from pneumoconiosis (HR=1.33, 95% CI 0.94 to 1.33) and COPD (HR=1.04, 95% CI 0.96 to 1.52) in models controlling for coal mine dust. We saw a significant relationship between coal mine dust exposure and lung cancer mortality (HR=1.70; 95% CI 1.02 to 2.83) but not with respirable silica (HR=1.05; 95% CI 0.90 to 1.23). In the most recent follow-up period (2000–2007) both exposures were positively associated with lung cancer mortality, coal mine dust significantly so. Conclusions Our findings support previous studies showing that exposure to coal mine dust and respirable silica leads to increased mortality from malignant and non-malignant respiratory diseases even in the absence of smoking.

1 January 2000 in Applied Occupational and Environmental Hygiene
Verified
Journal Article
Closed access
PSPeter A. Scheff
Peter A. Scheff
VPVidas K. Paulius
Vidas K. Paulius
SHSandra W. Huang
Sandra W. Huang
LCLorainne Conroy
Lorainne Conroy
The overall objective of the study was to evaluate the indoor air quality at a middle school with an emphasis on characterizing baseline conditions. The focus of this article is on the relationship between occupancy and measured concentrations of carbon dioxide, and an evaluation of the use of carbon dioxide as a tracer for ventilation in the school. The school was characterized as having no health complaints, good maintenance schedules, no carpeting within the classrooms or hallways, and no significant remodeling, and its officials had agreed to allow the sampling to take place during school hours. Monitoring followed the guidelines recommended in the "Preliminary Draft: Conceptual Standardized EPA Protocol For Characterizing Indoor Air Quality in School Buildings."(1) Four indoor locations including the cafeteria, a science classroom, an art classroom, and the lobby outside the main office, and one outdoor location were sampled for various environmental comfort and pollutant parameters for one week in February 1997. A consistent relationship between hourly occupancy and corresponding carbon dioxide concentrations was seen. Carbon dioxide concentrations in the cafeteria, art room, and lobby were within specified American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) guidelines for comfort (< 1000 ppm). The science room had the highest concentrations (frequently exceeding 1000 ppm) due to high occupancy and non-functioning unit ventilators. Measured ventilation rates were within specified ASHRAE guidelines for the art room, cafeteria, and lobby. The science room, which relied on natural ventilation only, was not able to meet the ASHRAE guideline on one of the three days studied. The use of a completely mixed space, one compartment mass balance model with estimated CO2 generation rates and measured CO2 concentrations is shown to be a useful method for evaluating ventilation. Modeled effective ventilation, air changes per hour, and mixing factors reflected measured carbon dioxide concentrations and measured ventilation in each room. Mechanical ventilation afforded better mixing than natural ventilation. This study demonstrates the usefulness of collecting indoor CO2 and occupancy data when carrying out indoor air quality evaluations in schools.

1 January 2000 in Applied Occupational and Environmental Hygiene
Verified
Journal Article
Closed access
PSPeter A. Scheff
Peter A. Scheff
VPVidas K. Paulius
Vidas K. Paulius
LCLuke Curtis
Luke Curtis
LCLorainne Conroy
Lorainne Conroy
A middle school (grades 6 to 8) in a residential section of Springfield, Illinois, with no known air quality problems, was selected for a baseline indoor air quality survey. The study was designed to measure and evaluate air quality at the middle school with the objective of providing a benchmark for comparisons with measurements in schools with potential air quality problems. The focus of this article is on the development of emission factors for particulate matter and bioaerosols. The school was characterized as having no health complaints and good maintenance schedules. Four indoor locations including the cafeteria, a science classroom, an art classroom, the lobby outside the main office, and one outdoor location were sampled for various environmental comfort and pollutant parameters for one week in February 1997. Integrated samples (eight-hour sampling time) for respirable and total particulate matter, and short-term measurements (two-minute samples, three times per day) for bioaerosols were collected on three consecutive days at each of the sampling sites. Continuous measurements of carbon dioxide were logged at all locations for five days. Continuous measurements of respirable particulate matter were also collected in the lobby area. A linear relationship between occupancy and corresponding carbon dioxide and particle concentrations was seen. A completely mixed space, one compartment mass balance model with estimated CO2 generation rates and actual CO2 and particulate matter concentrations was used to model ventilation and pollutant emission rates. Emission factors for occupancy were represented by the slope of emission rate versus occupancy scatter plots. The following particle and bioaerosol emission factors were derived from the indoor measurements: total particles: 1.28 mg/hr/personhr; respirable particles: 0.154 g/hr/person-hr; total fungi: 167 CFU/hr/person-min; thermophilic fungi: 35.8 CFU/hr/ person-min; mesophilic fungi: 119 CFU/hr/person-min; total bacteria: 227 CFU/hr/person-min; gram-negative bacte ria: 69.5 CFU/hr/person-min; gram-positive bacteria: 191 CFU/hr/person-min; Aspergillus: 17.0 CFU/hr/person-min; Penicillium: 161 CFU/hr/person-min; and yeasts: 16.4 CFU/ hr/person-min.

1 June 2005 in Atmospheric Environment
Verified
Journal Article
Closed access
ALAn Li
An Li
TSTodd M. Schoonover
Todd M. Schoonover
QZQimeng Zou
Qimeng Zou
FNFelice Norlock
Felice Norlock
LCLorainne Conroy
Lorainne Conroy
RWRichard A. Wadden
Richard A. Wadden

18 November 2004 in American Journal of Industrial Medicine
Verified
Journal Article
Closed access
PDF file
LFLinda Forst
Linda Forst
SLSteven Lacey
Steven Lacey
HCHua Yun Chen
Hua Yun Chen
RJRocio Jimenez
Rocio Jimenez
SBSusan Bauer
Susan Bauer
LCLorainne Conroy
Lorainne Conroy

1 March 2005 in Journal of Hospital Infection
Verified
Journal Article
Closed access
LCL. Curtis
L. Curtis
SCS. Cali
S. Cali
LCLorainne Conroy
Lorainne Conroy
KBK. Baker
K. Baker
COC.-H. Ou
C.-H. Ou
PSP. Scheff
P. Scheff