Seyyed Danial Nazemi

Mr. Seyyed Danial Nazemi

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2019 in Sustainable Cities and Society
Verified
Journal Article
Closed access
AGAli Ghofrani
Ali Ghofrani
SNSeyyed Danial Nazemi
Seyyed Danial Nazemi
MJMohsen A. Jafari
Mohsen A. Jafari

6 February 2016 in International Journal of Renewable Energy Development
Verified
Journal Article
Open access
PDF file
SNSeyyed Danial Nazemi
Seyyed Danial Nazemi
MBMehrdad Boroushaki
Mehrdad Boroushaki
In this paper, a mathematical model by which the thermal and physical behavior of a solar dish/Stirling system was investigated, then the system was designed, analysed and optimized. In this regard, all of heat losses in a dish/Stirling system were calculated, then, the output net-work of the Stirling engine was computed, and accordingly, the system efficiency was worked out. These heat losses include convection and conduction heat losses, radiation heat losses by emission in the cavity receiver, reflection heat losses of solar energy in the parabolic dish, internal and external conduction heat losses, energy dissipation by pressure drops, and energy losses by shuttle effect in displacer piston in the Stirling engine. All of these heat losses in the parabolic dish, cavity receiver and Stirling engine were calculated using mathematical modeling in MatlabTM software. For validation of the proposed model, a 10 kW solar dish/Stirling system was designed and the simulation results were compared with the Eurodish system data with a reasonable degree of agreement. This model is used to investigate the effect of geometric and thermodynamic parameters including the aperture diameter of the parabolic dish and the cavity receiver, and the pressure of the compression space of the Stirling engine, on the system performance. By using the PSO method, which is an intelligent optimization technique, the total design was optimized and the optimal values of decision-making parameters were determined. The optimization has been done in two scenarios. In the first scenario, the optimal value of each designed parameter has been changed when the other parameters are equal to the designed case study parameters. In the second scenario, all of parameters were assumed in their optimal values. By optimization of the modeled dish/Stirling system, the total efficiency of the system improved to 0.60% in the first scenario and it increased from 21.69% to 22.62% in the second scenario of the optimization, while the system variables changed slightly. Article History: Received Sept 28, 2015; Received in revised form January 08, 2016; Accepted February 15, 2016; Available online How to Cite This Article: Nazemi, S. D. and Boroushaki, M. (2016) Design, Analysis and Optimization of a Solar Dish/Stirling System. Int. Journal of Renewable Energy Development, 5(1), 33-42. http://dx.doi.org/10.14710/ijred.5.1.33-42

20 November 2019 in Journal of Building Performance Simulation
Verified
Journal Article
Closed access
AGAli Ghofrani
Ali Ghofrani
SNSeyyed Danial Nazemi
Seyyed Danial Nazemi
MJMohsen A. Jafari
Mohsen A. Jafari
A major challenge to devise smart HVAC control is to ensure that the control system considers the non-linearities in building hygrothermal relationships. In this paper, we propose hybrid data-driven approaches to capture these non-linearities and accurately predict building zone-level average temperature response to cooling in Variable Air Volume (VAV) systems. The proposed methodologies are based on the heat transfer analysis of a zone and done via neural network and multivariate linear regression models. Damper position is introduced as a categorical variable to alleviate the non-linearity in predictive indoor temperature models. The room temperature response to different damper positions from minimum airflow to maximum airflow is elaborated. Also, the impact of asset degradation on the response model is presented. The proposed model can enhance the control and optimization of building space cooling, and, be used to optimize building’s participation in demand response and load shifting.

31 May 2021 in Buildings
Verified
Journal Article
Open access
PDF file
SNSeyyed Danial Nazemi
Seyyed Danial Nazemi
MJMohsen a jafari
Mohsen a jafari
Esmat ZaidanEsmat Zaidan
Esmat Zaidan
The impact of load growth on electricity peak demand is becoming a vital concern for utilities. To prevent the need to build new power plants or upgrade transmission lines, power companies are trying to design new demand response programs. These programs can reduce the peak demand and be beneficial for both energy consumers and suppliers. One of the most popular demand response programs is the building load scheduling for energy-saving and peak-shaving. This paper presents an autonomous incentive-based multi-objective nonlinear optimization approach for load scheduling problems (LSP) in smart building communities. This model’s objectives are three-fold: minimizing total electricity costs, maximizing assigned incentives for each customer, and minimizing inconvenience level. In this model, two groups of assets are considered: time-shiftable assets, including electronic appliances and plug-in electric vehicle (PEV) charging facilities, and thermal assets such as heating, ventilation, and air conditioning (HVAC) systems and electric water heaters. For each group, specific energy consumption and inconvenience level models were developed. The designed model assigned the incentives to the participants based on their willingness to reschedule their assets. The LSP is a discrete–continuous problem and is formulated based on a mixed-integer nonlinear programming approach. Zoutendijk’s method is used to solve the nonlinear optimization model. This formulation helps capture the building collaboration to achieve the objectives. Illustrative case studies are demonstrated to assess the proposed model’s effect on building communities consisting of residential and commercial buildings. The results show the efficiency of the proposed model in reducing the total energy cost as well as increasing the participants’ satisfaction. The findings also reveal that we can shave the peak demand by 53% and have a smooth aggregate load profile in a large-scale building community containing 500 residential and commercial buildings.

1 March 2020 in The Electricity Journal
Verified
Journal Article
Closed access
KMKhashayar Mahani
Khashayar Mahani
SNSeyyed Danial Nazemi
Seyyed Danial Nazemi
MJMaryam Arabzadeh Jamali
Maryam Arabzadeh Jamali
MJMohsen A. Jafari
Mohsen A. Jafari

19 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
SNSeyyed Danial Nazemi
Seyyed Danial Nazemi
Esmat ZaidanEsmat Zaidan
Esmat Zaidan
MJMohsen a jafari
Mohsen a jafari
Cooling systems play a key role in maintaining human comfort inside buildings. The key challenges that are facing conventional cooling systems are the rapid growth of total cooling energy and annual electricity consumption in commercial buildings. This is even more significant in countries with an arid climate, where the cooling systems are typically working 80% of the year. Thus, there has been growing interest in developing smart control models to assign optimal cooling setpoints in recent years. In the present work, we propose an occupancy-based control model that is based on a non-linear optimization algorithm to efficiently reduce energy consumption and costs. The model utilizes a Monte-Carlo method to determine the approximate occupancy schedule for building thermal zones. We compare our proposed model to three different strategies, namely: always-on thermostat, schedule-based model, and a rule-based occupancy-driven model. Unlike these three rule-based algorithms, the proposed optimization approach is a white-box model that considers the thermodynamic relationships in the cooling system to find the optimal cooling setpoints. For comparison, different case studies in five cities around the world were investigated. Our findings illustrate that the proposed optimization algorithm is able to noticeably reduce the cooling energy consumption of the buildings. Significantly, in cities that were located in severe hot regions, such as Doha and Phoenix, cooling energy consumption can be reduced by 14.71% and 15.19%, respectively.