Karan V. I. S. Kaler

Prof. Karan V. I. S. Kaler


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2006 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
YLYoulan Li
Youlan Li
Colin DaltonColin Dalton
Colin Dalton
HCH. John Crabtree
H. John Crabtree
GNGregory Nilsson
Gregory Nilsson
KKKaran V. I. S. Kaler
Karan V. I. S. Kaler
We present a prototype microfluidic device developed for the continuous dielectrophoretic (DEP) fractionation and purification of sample suspensions of biological cells. The device integrates three fully functional and distinct units consisting of an injector, a fractionation region, and two outlets. In the sheath and sample injection ports, the cell sample are hydrodynamically focused into a stream of controlled width; in the DEP fractionation region, a specially shaped nonuniform (isomotive) electric field is synthesized and employed to facilitate the separation, and the sorted cells are then delivered to two sample collection ports. The microfluidic behavior of the injector region was simulated and then experimentally verified. The operation and performance of the device was evaluated using yeast cells as model biological particles. Issues relating to the fabrication and operation of the device are discussed in detail. Such a device takes a significant step towards an integrated lab-on-a-chip device, which could interface/integrate to a number of other on-chip components for the device to undertake the whole laboratory procedure.

5 December 2014 in Sensors
Verified
Journal Article
Open access
PDF file
KKKaran V. I. S. Kaler
Karan V. I. S. Kaler
RPRavi Prakash
Ravi Prakash
Droplet microfluidics (DMF) is a fluidic handling technology that enables precision control over dispensing and subsequent manipulation of droplets in the volume range of microliters to picoliters, on a micro-fabricated device. There are several different droplet actuation methods, all of which can generate external stimuli, to either actively or passively control the shape and positioning of fluidic droplets over patterned substrates. In this review article, we focus on the operation and utility of electro-actuation-based DMF devices, which utilize one or more micro-/nano-patterned substrates to facilitate electric field-based handling of chemical and/or biological samples. The underlying theory of DMF actuations, device fabrication methods and integration of optical and opto-electronic detectors is discussed in this review. Example applications of such electro-actuation-based DMF devices have also been included, illustrating the various actuation methods and their utility in conducting chip-based laboratory and clinical diagnostic assays.

1 June 2010 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
KKKaran V. I. S. Kaler
Karan V. I. S. Kaler
RPRavi Prakash
Ravi Prakash
DCDipankar Chugh
Dipankar Chugh
Liquid dielectrophoresis (L-DEP), when deployed at microscopic scales on top of hydrophobic surfaces, offers novel ways of rapid and automated manipulation of very small amounts of polar aqueous samples for microfluidic applications and development of laboratory-on-a-chip devices. In this article we highlight some of the more recent developments and applications of L-DEP in handling and processing of various types of aqueous samples and reagents of biological relevance including emulsions using such microchip based surface microfluidic (SMF) devices. We highlighted the utility of these devices for on-chip bioassays including nucleic acid analysis. Furthermore, the parallel sample processing capabilities of these SMF devices together with suitable on- or off-chip detection capabilities suggest numerous applications and utility in conducting automated multiplexed assays, a capability much sought after in the high throughput diagnostic and screening assays.

23 December 2014 in Micromachines
Verified
Journal Article
Open access
PDF file
RPRavi Prakash
Ravi Prakash
KPKanti Pabbaraju
Kanti Pabbaraju
SWSallene Wong
Sallene Wong
AWAnita Wong
Anita Wong
RTRaymond Tellier
Raymond Tellier
KKKaran V. I. S. Kaler
Karan V. I. S. Kaler
Quantitative, reverse transcription, polymerase chain reaction (qRT-PCR) is facilitated by leveraging droplet microfluidic (DMF) system, which due to its precision dispensing and sample handling capabilities at microliter and lower volumes has emerged as a popular method for miniaturization of the PCR platform. This work substantially improves and extends the functional capabilities of our previously demonstrated single qRT-PCR micro-chip, which utilized a combination of electrostatic and electrowetting droplet actuation. In the reported work we illustrate a spatially multiplexed micro-device that is capable of conducting up to eight parallel, real-time PCR reactions per usage, with adjustable control on the PCR thermal cycling parameters (both process time and temperature set-points). This micro-device has been utilized to detect and quantify the presence of two clinically relevant respiratory viruses, Influenza A and Influenza B, in human samples (nasopharyngeal swabs, throat swabs). The device performed accurate detection and quantification of the two respiratory viruses, over several orders of RNA copy counts, in unknown (blind) panels of extracted patient samples with acceptably high PCR efficiency (>94%). The multi-stage qRT-PCR assays on eight panel patient samples were accomplished within 35–40 min, with a detection limit for the target Influenza virus RNAs estimated to be less than 10 RNA copies per reaction.

27 December 2013 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
PDF file
RPR. Prakash
R. Prakash
KPK. Pabbaraju
K. Pabbaraju
SWS. Wong
S. Wong
AWA. Wong
A. Wong
RTR. Tellier
R. Tellier
KKKaran V. I. S. Kaler
Karan V. I. S. Kaler
Miniaturized bio-diagnostic devices have the potential to allow for rapid pathogen screening in clinical patient samples, as a low cost and portable alternative to conventional bench-top equipment. Miniaturization of key bio-diagnostic techniques, such as: nucleic acid detection and quantification, polymerase chain reaction (PCR), DNA fingerprinting, enzyme linked immunosorbent assay (ELISA), results in substantial reduction of reaction volumes (expensive samples/reagents) and shorter reaction times. Droplet microfluidics (DMF) is one of several miniaturized bio-sample handling techniques available for manipulating clinical samples and reagents in microliter (10−6 L) to picoliter (10−12 L) volume regime. Electro-actuation of sample and reagent in the form of droplets in the aforementioned volume regime, using dielectrophoresis (DEP) and/or Electrowetting (EW) are achieved by means of patterned, insulated metal electrodes on one or more substrates. In this work, we have utilized electro-actuation based DMF technology, integrated with suitably tailored resistive micro-heaters and temperature sensors, to achieve chip based real-time, quantitative PCR (qRT-PCR). This qRT-PCR micro-device was utilized to detect and quantify the presence of influenza A and C virus nucleic acids, using in-vitro synthesized viral RNA segments. The experimental analysis of the DMF micro-device confirms its capabilities in qRT-PCR based detection and quantification of pathogen samples, with accuracy levels comparable to established commercial bench-top equipment (PCR efficiency ∼95%). The limit of detection (LOD) of the chip based qRT-PCR technique was estimated to be ∼5 copies of template RNA per PCR reaction.

2 June 2007 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
APA. Ranjit Prakash
A. Ranjit Prakash
MAMatthias Amrein
Matthias Amrein
KKKaran V. I. S. Kaler
Karan V. I. S. Kaler