Julius Griskevicius

Dr. Julius Griskevicius

Biomechanical Engineering, Vilnius Gediminas Technical University, Vilnius, Vilniaus Miestas, Lithuania
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2023 in Electronics
Verified
Journal Article
Open access
PDF file
RMRytis Maskeliūnas
Rytis Maskeliūnas
RDRobertas Damaševičius
Robertas Damaševičius
Tomas BlažauskasTomas Blažauskas
Tomas Blažauskas
CCCenker Canbulut
Cenker Canbulut
AAAušra Adomavičienė
Aušra Adomavičienė
JGJulius Griskevicius
Julius Griskevicius
Remote patient monitoring is one of the most reliable choices for the availability of health care services for the elderly and/or chronically ill. Rehabilitation requires the exact and medically correct completion of physiotherapy activities. This paper presents BiomacVR, a virtual reality (VR)-based rehabilitation system that combines a VR physical training monitoring environment with upper limb rehabilitation technology for accurate interaction and increasing patients’ engagement in rehabilitation training. The system utilises a deep learning motion identification model called Convolutional Pose Machine (CPM) that uses a stacked hourglass network. The model is trained to precisely locate critical places in the human body using image sequences collected by depth sensors to identify correct and wrong human motions and to assess the effectiveness of physical training based on the scenarios presented. This paper presents the findings of the eight most-frequently used physical training exercise situations from post-stroke rehabilitation methodology. Depth sensors were able to accurately identify key parameters of the posture of a person performing different rehabilitation exercises. The average response time was 23 ms, which allows the system to be used in real-time applications. Furthermore, the skeleton features obtained by the system are useful for discriminating between healthy (normal) subjects and subjects suffering from lower back pain. Our results confirm that the proposed system with motion recognition methodology can be used to evaluate the quality of the physiotherapy exercises of the patient and monitor the progress of rehabilitation and assess its effectiveness.

20 June 2018 in Technology and Health Care
Verified
Journal Article
Closed access
PDF file
KDKristina Daunoraviciene
Kristina Daunoraviciene
AAAusra Adomaviciene
Ausra Adomaviciene
AGAgne Grigonyte
Agne Grigonyte
JGJulius Griskevicius
Julius Griskevicius
AJAlvydas Juocevicius
Alvydas Juocevicius
BACKGROUND: The study aims to determine the effectiveness of robot-assisted training in the recovery of stroke-affected arms using an exoskeleton robot Armeo Spring. OBJECTIVE: To identify the effect of robot training on functional recovery of the ar

26 November 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AAAndrius Apsega
Andrius Apsega
LPLiudvikas Petrauskas
Liudvikas Petrauskas
VAVidmantas Alekna
Vidmantas Alekna
Kristina DaunoravičienėKristina Daunoravičienė
Kristina Daunoravičienė
VSViktorija Sevcenko
Viktorija Sevcenko
JGJulius Griskevicius
Julius Griskevicius
Background and objectives: One of the greatest challenges facing the healthcare of the aging population is frailty. There is growing scientific evidence that gait assessment using wearable sensors could be used for prefrailty and frailty screening. The purpose of this study was to examine the ability of a wearable sensor-based assessment of gait to discriminate between frailty levels (robust, prefrail, and frail). Materials and methods: 133 participants (≥60 years) were recruited and frailty was assessed using the Fried criteria. Gait was assessed using wireless inertial sensors attached by straps on the thighs, shins, and feet. Between-group differences in frailty were assessed using analysis of variance. Associations between frailty and gait parameters were assessed using multinomial logistic models with frailty as the dependent variable. We used receiver operating characteristic (ROC) curves to calculate the area under the curve (AUC) to estimate the predictive validity of each parameter. The cut-off values were calculated based on the Youden index. Results: Frailty was identified in 37 (28%) participants, prefrailty in 66 (50%), and no Fried criteria were found in 30 (23%) participants. Gait speed, stance phase time, swing phase time, stride time, double support time, and cadence were able to discriminate frailty from robust, and prefrail from robust. Stride time (AUC = 0.915), stance phase (AUC = 0.923), and cadence (AUC = 0.930) were the most sensitive parameters to separate frail or prefrail from robust. Other gait parameters, such as double support, had poor sensitivity. We determined the value of stride time (1.19 s), stance phase time (0.68 s), and cadence (101 steps/min) to identify individuals with prefrailty or frailty with sufficient sensitivity and specificity. Conclusions: The results of our study show that gait analysis using wearable sensors could discriminate between frailty levels. We were able to identify several gait indicators apart from gait speed that distinguish frail or prefrail from robust with sufficient sensitivity and specificity. If improved and adapted for everyday use, gait assessment technologies could contribute to frailty screening and monitoring.

21 June 2018 in Parkinson's Disease
Verified
Journal Article
Open access
PDF file
DLDonatas Lukšys
Donatas Lukšys
GJGintaras Jonaitis
Gintaras Jonaitis
JGJulius Griskevicius
Julius Griskevicius
Background. Parkinson’s disease (PD) is a neurodegenerative disorder that affects human voluntary movements. Tremor is one of the most common symptoms of PD and is expressed as involuntary oscillation of the body. Tremors can be analysed in the frequency domain. Objective. The aim of the current study was to examine selected tremor parameters (frequency, root mean square, and approximated entropy) in order to quantify the characteristics of patients diagnosed with PD, compared to a healthy control group, and to compare the parameters by dividing the subjects according to UPDRS assessment. Methods. The subjects were divided into two groups: a group of people diagnosed with PD (n = 19) and a control group consisting of healthy volunteers (CO = 12). Each subject performed motor tasks specific to certain tremors: the finger-to-nose test. Each subject performed a motor task three times. A nine degree of freedom (DOF) wireless inertial measurement unit was used for the measurement of upper limb motor tasks. For the quantitative estimation of kinetic and postural tremors, dominant frequency, root means square, and approximation entropy were selected and calculated from the measured angular velocity and linear acceleration signals. A one-way ANOVA with a significance level of α = 0.05 was used to test the null hypothesis that the means of the tremor metrics were the same between the PD and CO groups. Results. Statistically significant differences between PD patients and control groups were observed in ApEn acceleration signal of kinetic tremor, ApEn angular velocity signal of kinetic tremor, ApEn angular velocity of postural tremor, frequency acceleration signal of postural tremor, and RMS angular speed kinetic tremor. Conclusion. Application of inertial measurement units for clinical research of patients and PD tremor evaluation allows providing quantitative information for diagnostic purposes, during screening in a clinical setting that differentiates between PD patients and controls.

1 May 2021 in Biomedical Signal Processing and Control
Verified
Journal Article
Open access
DLDonatas Lukšys
Donatas Lukšys
DJDalius Jatužis
Dalius Jatužis
GJGintaras Jonaitis
Gintaras Jonaitis
JGJulius Griskevicius
Julius Griskevicius

1 March 2018 in Technology and Health Care
Verified
Journal Article
Closed access
PDF file
Kristina DaunoravičienėKristina Daunoravičienė
Kristina Daunoravičienė
AAAusra Adomaviciene
Ausra Adomaviciene
DSDonatas Svirskis
Donatas Svirskis
JGJulius Griskevicius
Julius Griskevicius
AJAlvydas Juocevicius
Alvydas Juocevicius
BACKGROUND: Integration of the verticalization robot, Erigo, with functional electric stimulation and passive leg movements in the postacute rehabilitation of neurological patients could reduce the risk of secondary complications and improve functional outcomes (i.e. orthostatic hypotension, postural control and walking ability). OBJECTIVE: The aim of this study was to estimate and quantify changes in the postacute stage, mainly related to heart rate and blood pressure in functional recovery, postural parameters, walking ability and psychoemotional reactions, during training using the verticalization robot Erigo. METHODS: Six patients [three suffering from a stroke (ST) and three with spinal cord injuries (SCI)] participated in 10 sessions of physical therapy with the verticalization robot during primary inpatient rehabilitation. Functional state changes were assessed using clinical tests before and after the treatment, and the loading tolerance during Erigo training was noted. RESULTS: In early rehabilitation, Erigo training was safe and effective at improving orthostatic tolerance, posture and positive emotional reactions in both the ST and SCI patients ( P < 0.05). In addition, advanced technologies were more effective at boosting the orthostatic tolerance in SCI patients, while they were more effective at increasing the dynamic balance and walking ability in ST patients ( P < 0.05).