Respiratory rate (RR) monitoring is essential in neonatal intensive care units. Despite its importance, RR is still monitored intermittently by manual counting instead of continuous monitoring due to the risk of skin damage with prolonged use of contact electrodes in preterm neonates and false signals due to displacement of electrodes. Thermal imaging has recently gained significance as a non-contact method for RR detection because of its many advantages. However, due to the lack of information in thermal images, the selection and tracking of the region of interest (ROI) in thermal images for neonates are challenging. This paper presents the integration of visible (RGB) and thermal (T) image sequences for the selection and tracking of ROI for breathing rate extraction. The deep-learning based tracking-by-detection approach is employed to detect the ROI in the RGB images, and it is mapped to the thermal images using the RGB-T image registration. The mapped ROI in thermal spectrum sequences gives the respiratory rate. The study was conducted first on healthy adults in different modes, including steady, motion, talking, and variable respiratory order. Subsequently, the method is tested on neonates in a clinical settings. The findings have been validated with a contact-based reference method.The average absolute error between the proposed and belt-based contact method in healthy adults reached 0.1 bpm and for more challenging conditions was approximately 1.5 bpm and 1.8 bpm, respectively. In the case of neonates, the average error is 1.5 bpm, which are promising results. The Bland–Altman analysis showed a good agreement of estimated RR with the reference method RR and this pilot study provided the evidence of using the proposed approach as a contactless method for the respiratory rate detection of neonates in clinical settings.
This paper presents a machine vision–based precise tool positioning and verification system that may be used with milling and lathe machines, and so on. For many industrial applications, the accuracy required in machining operations is of the order of microns. The developed machine vision–based tool position verification process involves pixel calibration to compute and measure real-world minute dimensions. These measurements are based on two-dimensional spatial correlation of sequential images captured from the movement of the tool with a resolution of 250 µm. The captured sequential images are thresholded using a new bio-inspired technique named Negative Selection Algorithm, a model of Artificial Immune System. The developed system extracts the difference between the actual and target positions of the tool from the captured images through image processing and calculates the error. To compensate for the positional error, alignment commands are fed to the two-axis high precision motor. The maximum error observed was ±206 µm for 14.99999 mm movement.
Clinicians traditionally rely on manual inspection to assess the severity of diabetic foot ulcers (DFU). However, this approach is subjective and prone to errors. Effective deep learning classifiers may minimize the user’s dependency. In this manuscript, we propose a randomized, prospective, single-blind study focusing on diabetic neuropathy foot ulceration. The study included 104 subjects, with 71 patients (50 males) having DFU (Wagner grade 2) on the plantar aspect of the foot, while the remaining 33 subjects were non-diabetic (controlled) individuals (20 males). The average age of the patients was 54.28 ± 7.45 years, and the duration of the ulcers was 5.86 ± 2.22 months. The plantar foot was divided into three regions (forefoot, midfoot, and hindfoot) to detect ulcers in various areas. A new deep learning model, PFUTnet (Plantar Foot Ulcer Thermogram Network), was introduced to evaluate the severity of each area. When compared to existing deep learning models such as Inception V3 and AlexNet, PFUTnet demonstrated superior performance with a higher AUC score of 0.98 on the thermodataset. In terms of classification accuracy, PFUTnet achieved approximately 95%, while Inception V3 and AlexNet achieved around 93% and 90% respectively. The proposed technique enables automated and user-independent assessment of diabetic foot wounds, allowing for precise characterization of the severity of diabetic foot conditions.
Background: Accurate segmentation of the left ventricle in echocardiograms is crucial for the diagnosis and monitoring of cardiovascular diseases. However, this process is hindered by the limited availability of high-quality annotated datasets and the inherent complexities of echocardiogram images. Traditional methods often struggle to generalize across varying image qualities and conditions, necessitating a more robust solution. Objectives: This study aims to enhance left ventricular segmentation in echocardiograms by developing a framework that integrates Generative Adversarial Networks (GANs) for synthetic data augmentation with a MultiResUNet architecture, providing a more accurate and reliable segmentation method. Methods: We propose a GAN-based framework that generates synthetic echocardiogram images and their corresponding segmentation masks, augmenting the available training data. The synthetic data, along with real echocardiograms from the EchoNet-Dynamic dataset, were used to train the MultiResUNet architecture. MultiResUNet incorporates multi-resolution blocks, residual connections, and attention mechanisms to effectively capture fine details at multiple scales. Additional enhancements include atrous spatial pyramid pooling (ASPP) and scaled exponential linear units (SELUs) to further improve segmentation accuracy. Results: The proposed approach significantly outperforms existing methods, achieving a Dice Similarity Coefficient of 95.68% and an Intersection over Union (IoU) of 91.62%. This represents improvements of 2.58% in Dice and 4.84% in IoU over previous segmentation techniques, demonstrating the effectiveness of GAN-based augmentation in overcoming data scarcity and improving segmentation performance. Conclusions: The integration of GAN-generated synthetic data and the MultiResUNet architecture provides a robust and accurate solution for left ventricular segmentation in echocardiograms. This approach has the potential to enhance clinical decision-making in cardiovascular medicine by improving the accuracy of automated diagnostic tools, even in the presence of limited and complex training data.
26 August 2021 in IET Science, Measurement & Technology
Radiography is a widely used method for grading and tracking the anatomical changes in knee osteoarthritis (OA) patients. The ease of thermography in mapping functional information via the skin temperature (Tsk) helps in the diagnosis of various musculoskeletal diseases. There is a significant involvement of soft tissues in knee OA due to the complex osteoligamentous degeneration, which may affect the knee Tsk. A total of 62 patients with knee OA were analysed using thermography. The mean Tsk was computed by extracting the region of interest from the acquired thermal images using an automatic segmentation technique for frontal, lateral, and medial views. The mean Tsk for grade 1, 2, 3 and 4 were 30.96 ± 0.59, 31.56 ± 0.79, 31.40 ± 1.22, 32.20 ± 0.70 ˚C respectively. A significant temperature difference was found between grade 2 and 4 (p = 0.02, p = 0.018), grade 3 and 4 (p = 0.03, p = 0.02) for frontal and lateral views; whereas no significant difference was found between grade 2 and 3. Further, 2‐way ANOVA test showed that risk factors (like age, BMI and duration of disease) do affect the mean Tsk significantly with a p‐value of 0.0003, 0.02, and 0.008.
Thermal imaging-based techniques have recently emerged as a potential solution for the contactless measurement of breathing rate. However, these techniques were confined to detecting a single person’s breathing rate. In this paper, the simultaneous breathing monitoring of multiple persons is proposed by utilizing the cross-spectral visible-thermal image sequences. A cross-spectral multiple tracking-by-detection approach is used to detect multiple ROI in the visible spectrum and map the corresponding ROI in the thermal spectrum to extract the breathing signal. The linear coordinated mapping is performed by the use of a transformation matrix obtained from cross-spectral image registration. The results have been compared with the contact-based respiration belt for validation. The mean absolute error between estimated and belt-based measurements reached approximately 0.1 bpm (breaths per minute), 0.6 bpm, and 2.8 bpm for single, two, and three persons, respectively. The proposed method has a significant agreement and might be useful as a single measurement unit for contactless detection in the medical care centers, quarantine centers, and influenza screening at the airport.