Luis Fernando de Avila

Dr. Luis Fernando de Avila


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ESElias B. Santos
Elias B. Santos
CVChiara Valsecchi
Chiara Valsecchi
JGJaderson Goncalves
Jaderson Goncalves
LALuis Fernando de Avila
Luis Fernando de Avila
JMJacson de Menezes
Jacson de Menezes
Single-drop microextraction (SDME) was coupled with surface-enhanced Raman scattering (SERS) to provide sample extraction and pre-concentration for detection of analyte at low concentrations. A gold nanohole array substrate (AuNHAS), fabricated by interference lithography, was used as SERS substrate and para-mercaptobenzoic acid (p-MBA) was tested as a probe molecule, in the concentration range 10−8–10−4 mol L−1. With this approach, a limit of 10−7 mol L−1 was clearly detected. To improve the detection to lower p-MBA concentration, as 10−8 mol L−1, the SDME technique was applied. The p-MBA Raman signature was detected in two performed extractions and its new concentration was determined to be ~4.6 × 10−5 mol L−1. This work showed that coupling SDME with SERS allowed a rapid (5 min) and efficient pre-concentration (from 10−8 mol L−1 to 10−5 mol L−1), detection, and quantification of the analyte of interest, proving to be an interesting analytical tool for SERS applications.

1 December 2009 in European Polymer Journal
Verified
Journal Article
Closed access
LML.A.V. Mendes
L.A.V. Mendes
LALuis Fernando de Avila
Luis Fernando de Avila
JMJacson de Menezes
Jacson de Menezes
RPR.R. Pinho
R.R. Pinho
CLC.R.A. Lima
C.R.A. Lima
MRM.L.M. Rocco
M.L.M. Rocco

30 June 2007 in Polymer Degradation and Stability
Verified
Journal Article
Closed access
LML.A.V. Mendes
L.A.V. Mendes
RPR.R. Pinho
R.R. Pinho
LALuis Fernando de Avila
Luis Fernando de Avila
CLC.R.A. Lima
C.R.A. Lima
MRM.L.M. Rocco
M.L.M. Rocco

10 January 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CSCrystian Wilian Chagas Saraiva
Crystian Wilian Chagas Saraiva
SCSimone Coutinho Cardoso
Simone Coutinho Cardoso
DGDaniela Piai Groppo
Daniela Piai Groppo
ASAntônio Afonso Ferreira De Salles
Antônio Afonso Ferreira De Salles
LALuis Fernando de Avila
Luis Fernando de Avila
LRLuiz Antonio Ribeiro Da Rosa
Luiz Antonio Ribeiro Da Rosa
This study explores the possibility of a relationship between the sphericity degree of a target volume with the dose distribution. This relationship is evaluated based on the ratio isodose volume / target volume (IV/TV) and the metrics coverage, i.e., selectivity, gradient index, conformity index and mean dose when planning radiosurgery for vestibular schwannoma. Sphericity degree (φ) was calculated for each target volume (TV) of 64 patients who underwent stereotactic radiosurgery (SRS) for vestibular schwannoma. The calculation of this parameter was developed using the theoretical definition for operational sphericity φ = VP/VCS. The values found are evaluated considering the following metrics:—Coverage (C), selectivity (S), gradient index (GI), Paddick conformity index (CIPaddick) and dose distribution (IV/TV). The planning was also carried out considering a spherical target volume defined in a spherical phantom. The spherical volume is the same as the target used in the treatment plan. The planning of the spherical target was considered as a reference plan to evaluate the dose distribution inside and outside the volume. It was possible to observe that the majority of target volumes has (ϕ) around 0,66–0,77, corresponding to 54,7% of the total. Considering the mean values for metrics, the results are: C = 0,98, S = 0,78, GI = 3,11 and CI = 0,81. The dose distribution was equivalent for treatment plans and reference plans. Quantitative analysis for IV/TV shows that these values are higher than 30% for treatment plans where shot density is large. This study demonstrates that de sphericity degree (φ) can be related to the dose distribution (IV/TV). Therefore the sphericity degree is a good parameter to evaluate the dose distribution of a plan for vestibular schwannoma treatment, considering the reference plan as being a spherical target using a leksell gamma knife® perfexion (LGKP). This study shows that the sphericity degree offers important information of the dose distribution outside and inside the target volume. This is not evaluated by the other parameters already implemented as metric to analyzing the GKP plans.

1 February 2015 in Physica B: Condensed Matter
Verified
Journal Article
Closed access
LALuis Fernando de Avila
Luis Fernando de Avila
APA. Pradel
A. Pradel
SRSidney Ribeiro
Sidney Ribeiro
YMY. Messaddeq
Y. Messaddeq
Marcelo NalinMarcelo Nalin
Marcelo Nalin

14 June 2010 in Applied Optics
Verified
Journal Article
Closed access
PDF file
LALuis Fernando de Avila
Luis Fernando de Avila
AFA. A. Freschi
A. A. Freschi
LCLucila Cescato
Lucila Cescato
We use a holographic technique to measure simultaneously and separately the temporal evolution of the refractive-index and the absorption coefficient modulations induced by light in a photosensitive material. The technique is phase sensitive, allowing separation of the signals from the phase and from the amplitude grating. The refractive-index and the absorption coefficient modulations as well as the kinetic constant of the photoreaction in the positive photoresist SC 1827 were measured at three different wavelengths. The results were compared with independent measurements, performed under homogeneous exposition. The good accord demonstrates the applicability of the technique to study photosensitive materials.