Silvana De Iuliis

Dr. Silvana De Iuliis

Institute of Condensed Matter Chemistry and Technologies for Energy, Milano Unit – National Research Council (CNR), Milano, Italy
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 1998 in Combustion and Flame
Verified
Journal Article
Closed access
SISilvana De Iuliis
Silvana De Iuliis
MBM. Barbini
M. Barbini
SBS. Benecchi
S. Benecchi
FCF. Cignoli
F. Cignoli
GZG. Zizak
G. Zizak

1 May 2008 in Combustion and Flame
Verified
Journal Article
Closed access
FMF Migliorini
F Migliorini
SISilvana De Iuliis
Silvana De Iuliis
FCF Cignoli
F Cignoli
GZG Zizak
G Zizak

20 October 2001 in Applied Optics
Verified
Journal Article
Closed access
PDF file
FCFrancesco Cignoli
Francesco Cignoli
SISilvana De Iuliis
Silvana De Iuliis
VMVittorio Manta
Vittorio Manta
GZGiorgio Zizak
Giorgio Zizak
A two-dimensional soot diagnostic technique has been developed as an extension of the well-known two-color pyrometry. Two flame images are simultaneously collected on a CCD at selected wavelengths through suitable optics. By use of the dependence of soot emissivity on the soot volume fraction and by comparison with images from a calibrated light source, both the temperature field and the soot distribution can be determined. Validation was carried out through data obtained with other soot diagnostic methods on ethylene diffusion and Diesel oil-rich premixed flames. The current technique readily allowed us to obtain a large amount of data for a thorough description of the soot distribution within the flame. As an example of the technique’s potential, data about methane and propane diffusion flames are reported.

1 December 2005 in Applied Optics
Verified
Journal Article
Closed access
PDF file
SISilvana De Iuliis
Silvana De Iuliis
FCFrancesco Cignoli
Francesco Cignoli
GZGiorgio Zizak
Giorgio Zizak
A two-color version of the laser-induced incandescence (2C-LII) technique was implemented for measuring absolute soot volume fraction in flames. By using a calibrated tungsten ribbon lamp, soot peak temperatures were measured as a function of fluence at several locations in an ethylene diffusion flame by using a steeply edged laser beam profile. Above a certain fluence threshold, peak temperatures were tightly distributed just above 4000 K independent of the particle size and number density. Radial profiles of soot volume fraction were obtained and compared (not calibrated) with results from the laser extinction technique. Good agreement showed the validity of the 2C-LII technique at a controlled fluence.

1 January 2016 in Applied Energy
Verified
Journal Article
Closed access
LMLaura Merotto
Laura Merotto
CFC. Fanciulli
C. Fanciulli
RDRoberto Donde'
Roberto Donde'
SISilvana De Iuliis
Silvana De Iuliis

1 April 2018 in Applied Energy
Verified
Journal Article
Closed access
CFC. Fanciulli
C. Fanciulli
HAH. Abedi
H. Abedi
LMLaura Merotto
Laura Merotto
RDRoberto Donde'
Roberto Donde'
SISilvana De Iuliis
Silvana De Iuliis
FPFrancesca Passaretti
Francesca Passaretti