Sehwan Kim

Prof. Sehwan Kim

Department of Biomedical Engineering, College of Medicine, Vice Director, Beckman Laser Institute Korea, Dankook University, Korea (ROK)
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SCSo-Young Chang
So-Young Chang
MLMin Young Lee
Min Young Lee
PCPhil-Sang Chung
Phil-Sang Chung
Sehwan KimSehwan Kim
Sehwan Kim
BCBernard Choi
Bernard Choi
JJJae Yun Jung
Jae Yun Jung
Photobiomodulation (PBM) has been suggested to have a therapeutic effect on irreversible hearing loss induced by aminoglycosides, including gentamicin (GM). However, its intracellular mechanism(s) in GM-induced ototoxicity remain poorly understood. In the present study, we investigated the effect of PBM in GM-induced ototoxicity in auditory cells. We tried to characterize the downstream process by PBM, and the process that triggered the increased cell viability of auditory cells. As a result, the effects of PBM against GM-induced ototoxicity by increasing ATP levels and mitochondrial membrane potential was confirmed. These results suggest a theory to explain the therapeutic effects and support the use of PBM for aminoglycoside-induced hearing loss.

5 November 2025 in Journal of Medical Internet Research
Verified
Journal Article
Open access
HJHyunWoo Jung
HyunWoo Jung
DKDo Yeon Kim
Do Yeon Kim
ILILJU LEE
ILJU LEE
OKOk Kim
Ok Kim
SLSeungjin Lee
Seungjin Lee
JLJung Jae Lee
Jung Jae Lee
Background: The COVID-19 pandemic has intensified mental health issues globally, highlighting the urgent need for remote mental health monitoring. Digital phenotyping using smart devices has emerged as a promising approach, but it remains unclear which features are essential for predicting depression and anxiety. Objective: This study aimed to identify the types of features collected through smart packages—integrated systems combining smartphones with wearable devices such as Actiwatches, smart bands, and smartwatches—and to determine which features should be considered essential for mental health monitoring based on the type of device used. Methods: A systematic review was conducted. Searches were performed across Web of Science, PubMed, and Scopus on February 5, 2025. Inclusion criteria comprised quantitative studies involving adults (≥19 years) using smart devices to predict depression or anxiety based on passive data collection. Studies focusing solely on smartphones or qualitative designs were excluded. Risk of bias was assessed using the Mixed Methods Appraisal Tool and the Quality Criteria Checklist. Data were synthesized descriptively, and the relative contribution of each feature was further assessed by calculating coverage (proportion of studies using a feature) and importance among used (proportion identifying it as important when used). These metrics were visualized in quadrant-based scatter plots to identify consistently important features across devices. Results: From 1382 records, 22 studies across 11 countries were included. The overall synthesis identified a core feature package—accelerometer, steps, heart rate (HR), and sleep. Device-specific analyses revealed further nuances: in Actiwatch studies, accelerometer and activity were consistently important, but sleep features were rarely examined. In smart band studies, HR, steps, sleep, and phone usage were essential, while GPS, electrodermal activity (EDA), and skin temperature showed high importance when used, suggesting opportunities for broader adoption. In smartwatch studies, sleep and HR emerged as core features, whereas steps and accelerometer were widely used but often not identified as important. Conclusions: This systematic review identified a core feature package comprising accelerometer, steps, HR, and sleep that consistently contributes to mood disorder prediction across devices. At the same time, device-specific differences were observed: Actiwatch studies mainly emphasized accelerometer and activity but underused sleep features; smart bands highlighted HR, steps, sleep, and phone usage, with EDA, skin temperature, and GPS showing additional promise; and smartwatches most reliably leveraged sleep and HR, while steps and accelerometer were widely used yet less effective. These findings suggest that while a shared core set of features exists, optimizing digital phenotyping requires tailoring feature selection to the characteristics of each device type. To advance this field, improving data accessibility, particularly in smartwatch ecosystems, and adopting standardized reporting frameworks will be essential to enhance comparability, reproducibility, and future meta-analytic integration.

30 September 2020 in International Neurourology Journal
Verified
Journal Article
Open access
PDF file
AKAram Kim
Aram Kim
Sehwan KimSehwan Kim
Sehwan Kim
HKHyeong Gon Kim
Hyeong Gon Kim
Stress urinary incontinence (SUI) is a highly prevalent health condition that significantly impacts the quality of life. Traditional methods of treatment for SUI, such as pubovaginal sling and Burch colposuspension, have been replaced by the midurethral sling because of its high efficacy, low complication and morbidity rates, and short learning curve. Although multiple behavioral and operative treatments exist, midurethral slings are the gold standard for the treatment of SUI in women. However, several reports have raised concerns about complications caused by the synthetic mesh used in midurethral slings. Therefore, surgical treatment for SUI in women must be chosen with care, taking into account potential complications. Herein, we review the current safety issues pertaining to the use of meshes, the efficacy of traditional surgeries, old and new midurethral slings, and recent data comparing the efficacy and safety of different surgical options. This review is aimed at developing practical guidelines for choosing surgical options for women with SUI.

30 September 2021 in International Neurourology Journal
Verified
Journal Article
Open access
PDF file
AKAram Kim
Aram Kim
JAJae-Hak Ahn
Jae-Hak Ahn
WCWoo Suk Choi
Woo Suk Choi
HPHyoung Keun Park
Hyoung Keun Park
Sehwan KimSehwan Kim
Sehwan Kim
HKHyeong Gon Kim
Hyeong Gon Kim
Urinary tract infections (UTIs) are the most common infectious disease and are mainly caused by Escherichia coli. In this review, we introduce the current concept of recurrent UTI (rUTI) based on recent research dealing with pathophysiology of the disease. Although urine is considered sterile, recent studies dealing with microbiome have proposed different ideas. UTIs have typically been considered as extracellular infections, but recently, uropathogenic Escherichia coli (UPEC) has been shown to bind and replicate in the urothelium to make intracellular bacterial communities. Binding UPECs might proceed in many ways including extracellular expulsion for clearance or survival and quiescent intracellular reservoirs that can cause rUTI. Moreover, it is also suggested that other important factors, such as lipopolysaccharide and multimicrobial infection, can be the cause of rUTI. This review article reveals a key mechanism of recurrence and discusses what makes a pathway of resolution or recurrence in a host after initial infection.


31 May 2023 in International Neurourology Journal
Verified
Journal Article
Open access
PDF file
BKByeong-Il Kang
Byeong-Il Kang
AKAram Kim
Aram Kim
Sehwan KimSehwan Kim
Sehwan Kim
Purpose: Current guidelines recommend clean intermittent catheterization (CIC) at regular time intervals for patients with spinal cord injuries; however, many patients experience difficulties. Performing time-based CIC outside the home is a significant burden for patients. In this study, we aimed to overcome the limitations of the current guidelines by developing a digital device to monitor bladder urine volume in real-time.Methods: The optode sensor is a near-infrared spectroscopy (NIRS)-based wearable device intended to be attached to the skin of the lower abdomen where the bladder is located. The sensor’s primary function is to detect changes in urine volume within the bladder. An in vitro study was conducted using a bladder phantom that mimicked the optical properties of the lower abdomen. To validate the data in the human body at the proof-of-concept level, one volunteer attached the device to the lower abdomen to measure the light intensity between the first voiding and immediately before the second voiding.Results: The degree of attenuation at the maximum test volume was equivalent across experiments, and the optode sensor with multiplex measurements demonstrated robust performance for patient diversity. Moreover, the symmetric feature of the matrix was deemed a potential parameter for identifying the accuracy of sensor localization in a deep-learning model. The validated feasibility of the sensor showed almost the same results as an ultrasound scanner, which is routinely used in the clinical field.Conclusions: The optode sensor of the NIRS-based wearable device can measure the urine volume in the bladder in real-time.