Glen Kowach

Prof. Glen Kowach

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
IVIoana Voiculescu
Ioana Voiculescu
FLFang Li
Fang Li
GKGlen Kowach
Glen Kowach
KLKun-Lin Lee
Kun-Lin Lee
NMNicolas Mistou
Nicolas Mistou
RKRussell Kastberg
Russell Kastberg
The paper describes a stretchable, microfabricated power generator that will be attached on the skin and will produce energy based on the movements of the human body. The device was fabricated on a polymeric, elastomeric, poly(dimethylsiloxane) (PDMS) sheet. It consists of a piezoelectric thin film of ZnO sandwiched between two stretchable gold electrodes. An innovative technique was used for the deposition of ZnO thin film on the gold electrode-coated polymeric substrate at low temperatures below 150 °C. This is the first attempt to use a uniform film of ZnO, for energy harvesting. The ZnO film had the thickness at the submicron scale and the surface at the centimeter scale. We demonstrated that under a strain of 8% the voltage output from this power generator was equal to 2 V, the power output was equal to 160 μW and the corresponding power density was 1.27 mW/cm2. This device has great potential for application in power sensors attached on the human body, such as temperature sensors or wearable electrocardiography systems.

26 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
KLKun-Lin Lee
Kun-Lin Lee
GKGlen Kowach
Glen Kowach
FLFang Li
Fang Li
IVIoana Voiculescu
Ioana Voiculescu
Blood viscosity is the defining health indicator for hyperviscosity syndrome patients. This paper introduces an alternative approach for the real-time monitoring of blood viscosity by employing a surface-horizontal surface acoustic wave (SH-SAW) device at room temperature. A novel bi-layer waveguide is constructed on top of the SAW device. This device enables the SAW sensing of liquid droplets utilizing a bi-layer waveguide, consisting of a zinc oxide (ZnO) enhancement layer and Parlyene C, that facilitates the promotion of the surface horizontal mode. The ZnO piezoelectric thin-film layer enhanced the local particle displacement and dielectric coupling while the Parylene C layer constrained the wave mode at the interface of the piezoelectric material and polymer material. The device was tested with a liquid drop on the SAW delay-line path. Both experimental and finite element analysis results demonstrated the benefits of the bi-layer waveguide. The simulation results confirmed that the displacement field of local particles increased 9 times from 1.261 nm to 11.353 nm with the Parylene C/ZnO bi-layer waveguide structure. The device demonstrated a sensitivity of 3.57 ± 0.3125 kHz shift per centipoise enabling the potential for high precision blood viscosity monitoring.

22 December 2022 in Colorants
Verified
Journal Article
Open access
PDF file
AHAbed Haddad
Abed Haddad
TNToni Nakie-Miller
Toni Nakie-Miller
JJJosephine Brilliant Jenks
Josephine Brilliant Jenks
GKGlen Kowach
Glen Kowach
Synthetic organic dyes were extensively used by artists in the first half of the 20th century, knowingly or otherwise. This included Andy Warhol and his À la Recherche du Shoe Perdu (c. 1955), a major portfolio of hand-colored prints, a copy of which resides in the collection of The Museum of Modern Art (MoMA). Warhol and his friends were known to use Dr. Ph. Martin’s Synchromatic Transparent Water Colors to bring these prints to life. A historical set of Synchromatic Transparent Watercolors were initially investigated by UV-visible spectroscopy, and samples from the historic set were also characterized by µ-Fourier transform infrared spectroscopy for fingerprint identification. To better elucidate the nature of the mixtures present, thin-layer chromatography was coupled with surface-enhanced Raman spectroscopy to separate the components of all colorants in the set. The dyes decisively identified include Acid Red 73, Acid Red 87, Acid Red 17, Acid Red 103, Basic Red 1, Acid Orange 7, Acid Yellow 23, Acid Green 1, Basic Green 4, Acid Blue 3, Acid Blue 93, Basic Violet 3, Basic Violet 10, Basic Violet 17, and Acid Black 2. Overall, Acid Blue 3, along with Acid Orange 7 and Acid Black 2, were found in the greatest number of dyes in the Dr. Ph. Martin’s set. Data from the historic set was subsequently used for direct comparison with reflectance spectra from the Warhol portfolio using principal component analysis. Microfade testing on a Synchromatic Transparent Watercolors brochure was also conducted to identify fugitive colorants, the results of which were extrapolated to each of the prints in the Warhol portfolio. The analysis provided further insight into the dyes used in À la Recherche du Shoe Perdu and confirmed the extreme light sensitivity of some colorants and the fastness of others.