Pedro Villalba

Dr. Pedro Villalba

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2011 in Journal of Power Sources
Verified
Journal Article
Closed access
HGHumberto Gómez
Humberto Gómez
MRManoj K. Ram
Manoj K. Ram
FAFarah. Alvi
Farah. Alvi
PVPedro Villalba
Pedro Villalba
ESElias (Lee) Stefanakos
Elias (Lee) Stefanakos
AKAshok Kumar
Ashok Kumar

1 April 2012 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
PVPedro Villalba
Pedro Villalba
MRManoj K. Ram
Manoj K. Ram
HGHumberto Gomez
Humberto Gomez
Venkat R. BhethanabotlaVenkat R. Bhethanabotla
Venkat R. Bhethanabotla
MHMy N. Helms
My N. Helms
AKAshok Kumar
Ashok Kumar

29 April 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
FBFrancisco Burgos
Francisco Burgos
Alexander RodríguezAlexander Rodríguez
Alexander Rodríguez
ECEliana Cervera
Eliana Cervera
MAMarcio Andres DE AVILA
Marcio Andres DE AVILA
MSMarco Sanjuán
Marco Sanjuán
PVPedro Villalba
Pedro Villalba
A current challenge regarding microfluidic paper-based analytical devices (µPAD) for blood plasma separation (BPS) and electrochemical immunodetection of protein biomarkers is how to achieve a µPAD that yields enough plasma to retain the biomarker for affinity biosensing in a functionalized electrode system. This paper describes the development of a BPS µPAD to detect and quantify the S100B biomarker from peripheral whole blood. The device uses NaCl functionalized VF2 filter paper as a sample collection pad, an MF1 filter paper for plasma retention, and an optimized microfluidic channel geometry. An inverted light microscope, scanning electron microscope (SEM), and image processing software were used for visualizing BPS efficiency. A design of experiments (DOE) assessed the device’s efficacy using an S100B ELISA Kit to measure clinically relevant S100B concentrations in plasma. The BPS device obtained 50 μL of plasma from 300 μL of whole blood after 3.5 min. The statistical correlation of S100B concentrations obtained using plasma from standard centrifugation and the BPS device was 0.98. The BPS device provides a simple manufacturing protocol, short fabrication time, and is capable of S100B detection using ELISA, making one step towards the integration of technologies aimed at low-cost POC testing of clinically relevant biomarkers.

1 July 2011 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
PVPedro Villalba
Pedro Villalba
MRManoj K. Ram
Manoj K. Ram
HGHumberto Gomez
Humberto Gomez
AKAmrita Kumar
Amrita Kumar
Venkat R. BhethanabotlaVenkat R. Bhethanabotla
Venkat R. Bhethanabotla
AKAshok Kumar
Ashok Kumar

7 February 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
FBFrancisco Burgos-Flórez
Francisco Burgos-Flórez
ARAlexander Rodríguez
Alexander Rodríguez
ECEliana Cervera
Eliana Cervera
VZValtencir Zucolotto
Valtencir Zucolotto
MSMarco Sanjuán
Marco Sanjuán
PVPedro Villalba
Pedro Villalba
Point-of-Care (POC) testing for biomarker detection demands techniques that are easy to use, readily available, low-cost, and with rapid response times. This paper describes the development of a fully open-source, modular, wireless, battery-powered, smartphone-controlled, low-cost potentiostat capable of conducting electrochemical impedance spectroscopy for the electrochemical detection of the S100B protein captured in an ANTI-S100B functionalized thin-film gold interdigitated electrode platform to support traumatic brain injury diagnosis and treatment. EIS results from the developed potentiostat were validated with a commercial benchtop potentiostat by comparing impedance magnitude and phase values along the EIS frequency range. In addition, an experimental design was performed for detecting S100B in spiked human plasma samples with S100B concentrations of clinical utility, and a calibration curve was found for quantifying S100B detection. No statistically significant differences were found between EIS results from the developed potentiostat and the commercial potentiostat. Statistically significant differences in the changes in charge transfer resistance signal between each tested S100B concentration (p < 0.05) were found, with a limit of detection of 35.73 pg/mL. The modularity of the proposed potentiostat allows easier component changes according to the application demands in power, frequency excitation ranges, wireless communication protocol, signal amplification and transduction, precision, and sampling frequency of ADC, among others, when compared to state-of-the-art open-source EIS potentiostats. In addition, the use of minimal, easy acquirable open-source hardware and software, high-level filtering, accurate ADC, Fast Fourier Transform with low spectral leakage, wireless communication, and the simple user interface provides a framework for facilitating EIS analysis and developing new affordable instrumentation for POC biosensors integrated systems.

10 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Alexander RodríguezAlexander Rodríguez
Alexander Rodríguez
FBFrancisco Burgos-Flórez
Francisco Burgos-Flórez
JPJose Posada
Jose Posada
ECEliana Cervera
Eliana Cervera
Valtencir ZucolottoValtencir Zucolotto
Valtencir Zucolotto
PVPedro Villalba
Pedro Villalba
Neuronal damage secondary to traumatic brain injury (TBI) is a rapidly evolving condition, which requires therapeutic decisions based on the timely identification of clinical deterioration. Changes in S100B biomarker levels are associated with TBI severity and patient outcome. The S100B quantification is often difficult since standard immunoassays are time-consuming, costly, and require extensive expertise. A zero-length cross-linking approach on a cysteamine self-assembled monolayer (SAM) was performed to immobilize anti-S100B monoclonal antibodies onto both planar (AuEs) and interdigitated (AuIDEs) gold electrodes via carbonyl-bond. Surface characterization was performed by atomic force microscopy (AFM) and specular-reflectance FTIR for each functionalization step. Biosensor response was studied using the change in charge-transfer resistance (Rct) from electrochemical impedance spectroscopy (EIS) in potassium ferrocyanide, with [S100B] ranging 10–1000 pg/mL. A single-frequency analysis for capacitances was also performed in AuIDEs. Full factorial designs were applied to assess biosensor sensitivity, specificity, and limit-of-detection (LOD). Higher Rct values were found with increased S100B concentration in both platforms. LODs were 18 pg/mL(AuES) and 6 pg/mL(AuIDEs). AuIDEs provide a simpler manufacturing protocol, with reduced fabrication time and possibly costs, simpler electrochemical response analysis, and could be used for single-frequency analysis for monitoring capacitance changes related to S100B levels.