Christian X. Briceño-León

Dr. Christian X. Briceño-León

Universitat Politécnica de Valencia
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 October 2021 in Water
Verified
Journal Article
Open access
PDF file
Christian X. Briceño-LeónChristian X. Briceño-León
Christian X. Briceño-León
DSDiana Soraya Sanchez
Diana Soraya Sanchez
PIPedro L. Iglesias-Rey
Pedro L. Iglesias-Rey
F. Javier Martínez-SolanoF. Javier Martínez-Solano
F. Javier Martínez-Solano
DMDaniel Mora-Melia
Daniel Mora-Melia
Pumping station (PS) designs in water networks basically contemplate technical and economic aspects. Technical aspects could be related to the number of pumps in PS and the operational modes of PS. Meanwhile, economic aspects could be related to all the costs that intervene in a PS design, such as investment, operational and maintenance costs. In general, water network designs are usually focused on optimizing operational costs or investment costs, However, some subjective technical aspects have not been approached, such as determining the most suitable pump model, the most suitable number of pumps and the complexity of control system operation in a PS design. Therefore, the present work aims to select the most suitable pump model and determine the priorities that technical and economic factors could have in a PS design by a multi-criteria analysis, such as an analytic hierarchy process (AHP). The proposed work will contemplate two main criteria, and every criterion will be integrated by sub-criteria to design a PS. In this way, technical factors (number of pumps and complexity of the operating system) and economic factors (investment, operational and maintenance costs) will be considered for a PS design. The proposed methodology consists of realizing surveys to a different group of experts that determines the importance of one criterion over each other criterion in a PS design through pairwise comparisons. Finally, this methodology will provide importance weight for the criteria and sub-criteria on the PS. Besides, this work will perform a rating of the considered alternatives of pump models in every case study, evaluating quantitatively every alternative with every criterion in the PS design. The main objective of this work will select the most adequate pump model according to the obtained rating, considering technical and economic aspects in every case study.

12 February 2021 in Water
Verified
Journal Article
Open access
PDF file
Christian X. Briceño-LeónChristian X. Briceño-León
Christian X. Briceño-León
PIPedro L. Iglesias-Rey
Pedro L. Iglesias-Rey
F. Javier Martínez-SolanoF. Javier Martínez-Solano
F. Javier Martínez-Solano
DMDaniel Mora-Melia
Daniel Mora-Melia
Vicente S. Fuertes-MiquelVicente S. Fuertes-Miquel
Vicente S. Fuertes-Miquel
The control system’s point is to bring the pumping curve close to the set-point curve. That concept is essential for proper design of a pumping station. An adequate design is focused not only on selecting the total number of pumps and the type of control to use (flow or pressure), but it also is important to determine the optimal number of fixed speed pumps (FSPs) and variable speed pumps (VSPs) for each flow rate. This work discusses the most common methods and procedures for control systems on a design of pumping stations with a proposed methodology. This methodology consists of expressing the characteristics of the pumping curve and the set-point curve in a dimensionless form so that the methodology is standardized for any pump model and set-point curve. These formulations allow us to discuss how the characteristic of a pump and the set-point curve of the network influence the optimal number of FSPs and VSPs in energy terms. In general, the objective of this work is to determine the most suitable total number of pumps in a pumping station design and to determine the optimal pumping configuration in every flow rate, thus the consumed energy would be the minimum. Additionally, this methodology develops an expression to estimate the performance of a frequency inverter when a VSP operates at different rotational speeds. This work will be applied to different study cases, and the obtained results allow us to question several usual procedures for pumping control system. In general, it can be concluded that the number of pumps of a pumping system cannot be inferred in a simple form without a deep analysis of a control system.

1 March 2023 in Journal of Water Resources Planning and Management
Verified
Journal Article
Closed access
PDF file
Christian X. Briceño-LeónChristian X. Briceño-León
Christian X. Briceño-León
PIPedro L. Iglesias-Rey
Pedro L. Iglesias-Rey
F. Javier Martínez-SolanoF. Javier Martínez-Solano
F. Javier Martínez-Solano
Enrico CreacoEnrico Creaco
Enrico Creaco
This paper presents an innovative and comprehensive methodology considering yearly demand variability and environmental factors in the design of pumping stations serving closed water distribution systems. While a single daily pattern of demand is typically considered for the design in most cases in the literature, the new methodology considers a set of potential daily patterns of demand, each with its own probability of occurrence, both to obtain an accurate estimation of yearly operational costs and to guarantee the feasibility of the pumping station during the yearly demand peak. As an additional novelty of this work, environmental criteria, such as the impact in terms of greenhouse gas emissions, are considered in the design and combined with technical and economic criteria to rank various design alternatives based on the analytic hierarchy process (AHP). The methodology proves that it can yield cost-effective, technically sound, and environmentally friendly solutions in systems with various characteristics. The main contribution of this work is that it presents a standardized methodology for pumping station design in water distribution networks. An important advantage of this method is that it reduces the subjectivity of the designer and avoids assumptions during the design process by applying multicriteria decision analysis. This new method of pumping station design brings a different point of view to traditional design methods. While traditional design methods focus on minimizing project costs and operational costs, this new methodology considers technical, environmental, and economic aspects in a comprehensive manner during the design process. In addition, it considers demand variability in the design process, highlighting its effects and its importance in the case studies presented in this paper. In short, this methodology can be applied in any kind of pumping station design for real water distribution networks of different sizes. The results that this methodology yields demonstrate that pumping station solutions can be technically feasible and simple, economically profitable, and environmentally sound.

24 May 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
Diana Sanchez - FerrerDiana Sanchez - Ferrer
Diana Sanchez - Ferrer
Christian X. Briceño-LeónChristian X. Briceño-León
Christian X. Briceño-León
PIPedro L. Iglesias-Rey
Pedro L. Iglesias-Rey
F. Javier Martínez-SolanoF. Javier Martínez-Solano
F. Javier Martínez-Solano
Vicente S. Fuertes-MiquelVicente S. Fuertes-Miquel
Vicente S. Fuertes-Miquel
The pumping station is a very important hydraulic system in urban water supplies because the pumps raise the water head, ensuring the minimum pressure required in drinking water systems. In the design of a pumping station, one of the most important criteria is the number of pumps. However, in the traditional design, this criterion is defined arbitrarily. The other criteria are defined from the number of pumps and can produce a design that is not optimal. In addition, the traditional design does not consider the importance of the environment in choosing the pumps. The objective of this paper is to define a new design methodology for pumping stations. It has been developed using a multicriteria analysis in which nine criteria are evaluated. The application of the analytic hierarchy process (AHP) allows for finding an optimal solution. These design criteria have been associated in three cluster factors: technical factors; environmental factors; and economic factors. The results obtained allow us not only to validate the methodology but also to offer a solution to the problem of determining the most suitable model and the number of pumps for a pumping station.

12 November 2019 in Proceedings
Verified
Conference Paper
Open access
PDF file
Christian X. Briceño-LeónChristian X. Briceño-León
Christian X. Briceño-León
PIPedro L. Iglesias-Rey
Pedro L. Iglesias-Rey
F. Javier Martínez-SolanoF. Javier Martínez-Solano
F. Javier Martínez-Solano
Proper design of a pumping system requires the use of a pump curve and set-point curve system. Both have to be as close as possible to optimize energy use. This is achieved by control systems in which the type of control (flow or pressure) and the combination between fixed speed drive (FSD) pumps and variable speed drive (VSD) pumps are involved. The objective of this work is to determine the optimal number of FSD and VSD pumps for each flow rate range in order to discuss the classic design of pumping stations and their control systems. For this, a methodology is applied that defines the parametric form of the pump curve, efficiency curve, and set-point curve in relation to the most efficient point. In this way, dimensionless expressions are obtained and the influence of the set-point parameters on the design of the control system can be analyzed. Additionally, the method includes an expression that estimates the performance of the frequency inverter, which is based on the load and pump speed rotation. The application of the methodology to different case studies allows us to question many classic procedures for pumping stations. In summary, it can be concluded that the appropriate number of variable speed pumps for each control system cannot be established in advance but requires an in-depth study of different available options.

27 August 2023 in Water
Verified
Journal Article
Open access
PDF file
Christian X. Briceño-LeónChristian X. Briceño-León
Christian X. Briceño-León
PIPedro L. Iglesias-Rey
Pedro L. Iglesias-Rey
F. Javier Martínez-SolanoF. Javier Martínez-Solano
F. Javier Martínez-Solano
Enrico CreacoEnrico Creaco
Enrico Creaco
A proper pumping station (PS) design should consider multiple criteria, such as technical, economic, and environmental aspects. The analytic hierarchy process (AHP) method can be applied for multi-criteria analysis in this type of engineering design, and it is based on the judgment of a group of experts for the criteria considered. On the other hand, the most common method for PS design is one based solely on economic aspects or life cycle cost (LCC). This paper presents a sensitivity analysis of the impact of the hydraulic conditions of a water distribution network (WDN) on the ultimate solution in two PS design approaches. The first approach was the classic method based on LCC minimization and the second approach was based on multi-criteria analysis by means of AHP accounting for technical, economic, and environmental aspects. In this way, the effects of different meaningful variables for PS design, such as the mean demand, parameters of the setpoint curve, electric tariffs, and interest rates, were evaluated to determine the robustness of the PS solutions obtained. The obtained results of the sensitivity analysis in the case study demonstrated that the PS design based on multiple criteria decision analysis was more reliable and robust than the classic PS design against variations that can occur in a WDN, especially in the mean flow, setpoint curve, and electric tariff. The variations in these parameters of the WDN did not impact the ultimate solutions of the PS design approaches when within the tolerance ranges, but these ranges were wider in the second approach to PS design than in the first approach.