Label-free, size-dependent, and high-throughput isolation of rare tumor cells from untreated whole blood is enabled by interfacial viscoelastic microfluidics.
The microfluidic passive control of microparticles largely relies on the hydrodynamic effects of the carrier media such as Newtonian fluids and viscoelastic fluids. Yet the viscoelastic/Newtonian interfacial effect has been scarcely investigated, especially for high-resolution particle separation. Here we report a microfluidic co-flow of Newtonian (water or PBS) and viscoelastic fluids (PEO) for the size-dependent separation of microparticles. The co-flow condition generates a stable viscoelastic/Newtonian interface, giving rise to the wall-directed elastic lift forces that compete with the center-directed lift forces, and efficiently hinders the migration of microparticles from the Newtonian to the viscoelastic fluid in a size-dependent manner. An almost complete separation of a binary mixture of 1 μm and 2 μm polystyrene particles is achieved by the co-flow of water and a very dilute PEO solution (100 ppm), whereas the sole use of water or PEO could not lead to an efficient separation. This co-flow microfluidic system is also applied for the separation of Staphylococcus aureus (1 μm) from platelets (2–3 μm) with >90% efficiencies and purities.
This work presents an AC electrokinetic impedance sensing method that is capable of detecting specific interactions between macromolecules such as antigen–antibody binding. Serum samples were added to the surface of interdigitated electrodes that had been coated with bacterial antigens. After applying an AC signal of 100 mV at a specific frequency continuously, the electrodes' impedance change was recorded and used to determine the occurrence and level of antibody binding to the antigen. Our theoretical analysis indicated that with this AC signal, the target macromolecules will experience a sufficiently strong attraction force towards the electrode surface for acceleration of the binding process. Using this method, 11 human tuberculosis and 10 bovine tuberculosis serum samples were tested. The results were consistent with those obtained by a conventional ELISA method. The limit of detection of the impedance sensing method was estimated to be better than 10 ng mL−1. In summary, we demonstrate that AC electrokinetic impedance sensing can be used for rapid and sensitive detection of specific antibodies in serum samples. This method may form a basis for development of a point of care diagnostic device for human and bovine tuberculosis.