Yu-Wei Cheng

Prof. Yu-Wei Cheng

Department of Chemical Engineering, Ming Chi University of Technology, New Taipei City 24301, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Colloids and Surfaces A: Physicochemical and Engineering Aspects
Verified
Journal Article
Closed access
Ruey-Shin JuangRuey-Shin Juang
Ruey-Shin Juang
KWKuan-Syun Wang
Kuan-Syun Wang
Yu-Wei ChengYu-Wei Cheng
Yu-Wei Cheng
CFChun-Chieh Fu
Chun-Chieh Fu
WCWan-Tzu Chen
Wan-Tzu Chen
TLTing-Yu Liu
Ting-Yu Liu

6 March 2017 in Polymers
Verified
Journal Article
Open access
PDF file
CCChia-Yen Chiang
Chia-Yen Chiang
Ting-Yu LiuTing-Yu Liu
Ting-Yu Liu
YSYu-An Su
Yu-An Su
CWChien-Hsin Wu
Chien-Hsin Wu
Yu-Wei ChengYu-Wei Cheng
Yu-Wei Cheng
Ru-Jong JengRu-Jong Jeng
Ru-Jong Jeng
We have successfully developed novel surface-enhanced Raman scattering (SERS) substrates with three-dimensional (3D) porous structures for effectively improving the sensitivity and reproducibility of SERS, which can rapidly detect small molecules (rhodamine 6G as an example). Periodical arrays of the honeycomb-like substrates were fabricated by self-assembling polyurethane-co-azetidine-2,4-dione (PU-PAZ) polymers. PU-PAZ comprising amphiphilic dendrons could stabilize the phase separation between the water droplets and polymer solution, and then organize into regular porous structures during the breath figure method. Subsequently, SERS substrates were fabricated by immobilizing gold nanoparticles (AuNPs) onto the honeycomb-like films with various 3D porous structures, controlled by the different PU-PAZ concentrations and relative humidities. Results show that surface enhancement factors of honeycomb-like substrates were 20 times higher than that of flat-film substrates (control group) due to enormous hot-spots resonance effects by the 3D porous structure, verified through Raman mapping at various positions of the z-axis. Furthermore, the particle size effects were evaluated by immobilized 12 and 67 nm of AuNPs on the honeycomb-like substrates, indicating larger AuNPs could induce more pronounced hot-spots effects. The generation of hot-spots resonance to enhance Raman intensity is strongly dependent on the diameter of AuNPs and the pore size of the honeycomb-like and 3D porous substrates for label-free and rapid SERS detection.

1 May 2020 in Surface and Coatings Technology
Verified
Journal Article
Closed access
Yu-Wei ChengYu-Wei Cheng
Yu-Wei Cheng
CHChia-Wei Hsiao
Chia-Wei Hsiao
ZZZi-Ling Zeng
Zi-Ling Zeng
WSWei-Lin Syu
Wei-Lin Syu
Ting-Yu LiuTing-Yu Liu
Ting-Yu Liu

18 September 2019 in Polymers
Verified
Journal Article
Open access
PDF file
MYMing-Chien Yang
Ming-Chien Yang
HTHui-Ming Tsou
Hui-Ming Tsou
Yu-Sheng HsiaoYu-Sheng Hsiao
Yu-Sheng Hsiao
Yu-Wei ChengYu-Wei Cheng
Yu-Wei Cheng
CLChe-Chun Liu
Che-Chun Liu
CHChuan-Chih Hsu
Chuan-Chih Hsu
In this study, a novel hemocompatible coating on stainless steel substrates was prepared by electrochemically copolymerizing 3,4-ethylenedioxythiophene (EDOT) with graphene oxide (GO), polystyrene sulfonate (PSS), or heparin (HEP) on SUS316L stainless steel, producing an anti-fouling (anti-protein adsorption and anti-platelet adhesion) surface to avoid the restenosis of blood vessels. The negative charges of GO, PSS, and HEP repel negatively charged proteins and platelets to achieve anti-fouling and anti-clotting. The results show that the anti-fouling capability of the poly(3,4-ethylenedioxythiophene) (PEDOT)/PSS coating is similar to that of the PEDOT/HEP coating. The anti-fouling capability of PEDOT/GO is higher than those of PEDOT/HEP and PEDOT/PSS. The reason for this is that GO exhibits negatively charged functional groups (COO−). The highest anti-fouling capability was found with the PEDOT/GO/HEP coating, indicating that electrochemical copolymerization of PEDOT with GO and HEP enhances the anti-fouling capability. Furthermore, the biocompatibility of the PEDOT coatings was tested with 3T3 cells for 1–5 days. The results show that all PEDOT composite coatings exhibited biocompatibility. The blood clotting time (APTT) of PEDOT/GO/HEP was prolonged to 225 s, much longer than the 40 s of pristine SUS316L stainless steel (the control), thus greatly improving the anti-blood-clotting capability of cardiovascular stents.

2 July 2022 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
MYMing-Chien Yang
Ming-Chien Yang
AHAndri Hardiansyah
Andri Hardiansyah
Yu-Wei ChengYu-Wei Cheng
Yu-Wei Cheng
HLHung-Liang Liao
Hung-Liang Liao
KWKuan-Syun Wang
Kuan-Syun Wang
Ting-Yu LiuTing-Yu Liu
Ting-Yu Liu

19 September 2024 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
NBNazar Riswana Barveen
Nazar Riswana Barveen
SCSathishkumar Chinnapaiyan
Sathishkumar Chinnapaiyan
CZChe-Wei Zeng
Che-Wei Zeng
CHChi-Hsien Huang
Chi-Hsien Huang
YLYen-Yu Lin
Yen-Yu Lin
Yu-Wei ChengYu-Wei Cheng
Yu-Wei Cheng