Jing Lv

Dr. Jing Lv


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2020 in Construction and Building Materials
Verified
Journal Article
Closed access
JLJing Lv
Jing Lv
TZTianhua Zhou
Tianhua Zhou
QDQiang Du
Qiang Du
KLKunlun Li
Kunlun Li

26 June 2017 in International Journal of Civil Engineering
Verified
Journal Article
Closed access
PDF file
QDQiang Du
Qiang Du
JWJing Wei
Jing Wei
JLJing Lv
Jing Lv

28 August 2020 in Materials
Verified
Journal Article
Open access
PDF file
QDQiang Du
Qiang Du
CCChanglu Cai
Changlu Cai
JLJing Lv
Jing Lv
JWJiao Wu
Jiao Wu
TPTing Pan
Ting Pan
JZJie Zhou
Jie Zhou
This study investigated fundamental mechanical properties of a basalt fiber reinforced engineered cementitious composite (BF-ECC) with different volume fractions of basalt fiber (BF), water–binder ratio (W/B) and fly ash (FA) content. The compressive strength, splitting tensile strength, flexural strength and static modulus of BF-ECC were studied at 3, 28 and 56 days, respectively, to explore their development along the ages. Furthermore, the scanning electron microscopy (SEM) analysis was conducted to evaluate the microstructure of BF-ECC. Experiment results demonstrated that bond quality between the BF and the matrix is good, which leads to a significant increase in the flexural strength and splitting tensile strength. The pozzolanic effect of FA obviously improved the splitting tensile and flexural strength of BF-ECC after 56 days of curing, and the appropriate content of the FA content in the BF-ECC ranges from 50% to 60%.

1 December 2017 in Construction and Building Materials
Verified
Journal Article
Closed access
JLJing Lv
Jing Lv
TZTianhua Zhou
Tianhua Zhou
QDQiang Du
Qiang Du
HWHanheng Wu
Hanheng Wu

3 February 2020 in Sustainability
Verified
Journal Article
Open access
PDF file
JLJing Lv
Jing Lv
TZTianhua Zhou
Tianhua Zhou
KLKunlun Li
Kunlun Li
Reducing consumption of cement in concrete will achieve huge benefits in decline of carbon emission, conservation of natural resources and reduction of the cost of concrete. In this paper, the low-cement-consumption concrete, preplaced aggregate concrete (PAC), is prepared and 12 types of mixtures including four water–binder ratios (W/B) and three sand–binder ratios (S/B) are designed to detect the effect of W/B and S/B on the mechanical properties and failure mechanism of PAC. Experimental and analytic results indicate that the cubic compressive strength of PAC, splitting tensile strength of PAC and elastic modulus of PAC decrease with increase in W/B and S/B. At a similar compressive strength, more than 20% increment of elastic modulus of PAC is achieved when compared with normal concrete (NC); the descent stage of stress–strain curves of PAC are steeper than that of NC and the peak strains of PAC is lower than that of NC. Guo’s model with suitable values of parameters a and b can be used to describe the stress–strain relationship of PAC. Replacing NC by PAC in concrete structures will save 15–20% cement and achieve great environmental and economic benefits.

9 January 2020 in Materials
Verified
Journal Article
Open access
PDF file
JLJing Lv
Jing Lv
TZTianhua Zhou
Tianhua Zhou
QDQiang Du
Qiang Du
KLKunlun Li
Kunlun Li
LJLiangwei Jin
Liangwei Jin
In order to investigate the bond behavior of preplaced aggregate concrete-filled steel tube (CFT-PAC) columns and the difference of bond behavior between CFT-PAC columns and normal concrete-filled steel tube (CFT-NC) columns, a total of 11 columns were prepared and the push-out tests were conducted. The experimental parameters included the type of concrete (preplaced aggregate concrete and normal concrete), concrete strength (C40, C50 and C60), cross-section dimension (D = 219 mm, 299 mm and 351 mm) and the thickness of steel tube (t = 6 mm and 8 mm). The results indicated that the CTF-PAC columns had a similar load-slip curves with CFT-NC columns. The bond stresses of the CFT-PAC columns were higher than that of the PAC-NC columns at the same concrete strength. Increasing compressive strength of PAC increased the critical bond strength and bond strength of CFT-PAC columns. With an increase of the L/D ratio, both of the slip corresponding to peak load and bond strength of CFT-PAC columns exhibited an increasing trend. A rise in the D/t ratio led to a decrease in the bond stress of CFT-PAC columns and an increase in slip corresponding to the peak load of CFT-PAC columns. The proposed bond stress–slip relationship model considerably matched the bond stress–slip relationship of CFT-PAC columns.