Jonghwa Oh

Prof. Jonghwa Oh

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2019 in Workplace Health & Safety
Verified
Journal Article
Closed access
THTasha Heaton
Tasha Heaton
LHLaura K. Hurst
Laura K. Hurst
AAAzita Amiri
Azita Amiri
CLClaudiu T. Lungu
Claudiu T. Lungu
JOJonghwa Oh
Jonghwa Oh
In the United States, there are more than 120,000 nail salons in which workers could be potentially exposed to a number of volatile organic compounds (VOCs) used in various procedures. Measuring workers exposure in the field is time-consuming and could be very expensive. The purpose of this study was to estimate the VOC levels in the proximity of workers in nail salons through simulating the application process of some popular nail polishes in a laboratory chamber. The worst-case scenario was defined as a worker’s exposure during nail polish application to one set of fingernails every 15 minutes for an 8-hour shift (total nail sets = 32). Nail polish was applied on paper plates in a flow-controlled test chamber. Air was sampled during the application of five different nail polishes for 8 hours using passive air samplers and the experiment was triplicated. Passive samplers were used for VOCs and formaldehyde. In this worst-case scenario setting, a total of 17 VOCs were detected, with eight that were found in all the samples. The mean concentration of butyl acetate (161-330 ppm, parts per million) and ethyl acetate (440 ppm) exceeded the threshold limit value (TLV) of 150 ppm and 400 ppm, respectively. Formaldehyde was analyzed separately and the mean concentrations exceeded the TLV of 0.10 ppm in all types of nail polish, ranging from 0.12 ppm to 0.22 ppm. Occupational safety and health professionals could use these data to increase awareness of workers’ potential exposure to high levels of VOCs in nail salons and recommend practical measures to reduce potential exposures.

5 January 2022 in Journal of the Air & Waste Management Association
Verified
Journal Article
Closed access
MSMargaret Summers
Margaret Summers
JOJonghwa Oh
Jonghwa Oh
Claudiu T LunguClaudiu T Lungu
Claudiu T Lungu
In the context of workplace safety, activated carbon in the fiber form (i.e., activated carbon fiber, ACF) represents an alternative adsorbent to granular activated carbon (GAC) for use in organic vapor respiratory protection devices. ACFs are high surface area carbonaceous materials that are often available in a self-supporting non-woven form. The physical form of ACF suggests the potential for a filtration medium that is capable of supporting both organic vapor adsorption and particulate filtration. To study the application of these materials in respiratory protection devices, ACFs (ACFF 1200 m2/g, ACFF 1800 m2/g, and ACFF 2000 m2/g) were challenged with representative organic vapors (toluene, hexane, and methyl ethyl ketone (MEK)) at an occupationally relevant concentration (200 ppm). Breakthrough curves were generated for at least three different bed weights of adsorbent. Pressure drop (i.e., the resistance across the filtration media) was also measured to determine maximum ACF bed depths for use in respiratory protection devices. Breakthrough experiments indicate that ACFF 2000 has the highest adsorption capacity for toluene (381 mg/g), followed by ACFF 1800 and ACFF 1200 (344 mg/g and 239 mg/g, respectively). A similar trend was observed for hexane: 221 mg/g, 196 mg/g, and 146 mg/g for ACFF 2000, ACFF 1800, and ACFF 1200, respectively. ACFF 1200 showed the highest adsorption capacity for the polar adsorbate MEK (168 mg/g), followed by ACFF 1800 and ACFF 2000 (166 mg/g and 147 mg/g, respectively). Based on the constraints of pressure drop, it seems unlikely the exclusive use of ACF in a filtering facepiece respirator can provide an adsorbent mass sufficient for full shift protection against organic vapor contaminants at or above the legally enforceable permissible exposure level (PEL). Nevertheless, the incorporation of ACF into a facepiece respirator appears promising for “nuisance odor” applications; i.e., the further reduction of organic vapor concentrations when workplace exposures are already below PEL concentrations. Implications: This research brings innovation to the field of occupational health and air pollution control technology by investigating the adsorption performance of activated carbon fiber (ACF) media in the context of worker respiratory protection. ACF properties such as high specific surface area (m2/g), high permeability to airflow, and rapid adsorption kinetics make it ideal for use in thin, N95-style respirators for organic vapors. Respiratory protection is an exciting and relevant application for ACF media. A lightweight adsorbent such as ACF, if incorporated into an N95-style respirator, could potentially provide nuisance-level VOC protection in a physical form that is accessible to workers and consistent with OSHA’s voluntary use provisions for facepiece respirators. The research presented in this manuscript represents one of several steps planned in the characterization of ACF media for this particular application.

Jo Anne BalanayJo Anne Balanay
Jo Anne Balanay
JOJonghwa Oh
Jonghwa Oh
Respirator use has been shown to be associated with overall discomfort. Activated carbon fiber (ACF) has potential as an alternative adsorbent for developing thinner, lightweight, and efficient respirators due to its larger surface area, microporosity, and fabric form. The purpose of this pilot study was to determine the adsorption characteristics of commercially available ACF in respirator cartridges with varying ACF composition for toluene protection. Seven ACF types (one cloth, six felt) with varying properties were tested. Seven ACF cartridge configurations with varying ACF composition were challenged with five toluene concentrations (20–500 ppm) at constant air temperature (23 °C), relative humidity (50%), and air flow (32 LPM). Breakthrough curves were obtained using photoionization detectors. Breakthrough times (10%, 50%, and 5 ppm) and adsorption capacities were compared among ACF cartridge configurations to determine their suitable application in respiratory protection. Results showed that ACF cartridges containing the densest ACF felt types had the longest average breakthrough times (e.g., ~250–270 min to reach 5 ppm breakthrough time) and those containing ACF felt types with the highest specific surface areas had the highest average adsorption capacity (~450–470 mg/g). The ACF cartridges demonstrated breakthrough times of <1 h for 500 ppm toluene and 8–16 h for 20 ppm toluene. The ACF cartridges are more reliable for use at low ambient toluene concentrations but still have potential for use at higher concentrations for short-term protection. ACF felt forms with appropriate properties (density of ~0.07 g/cm3; specific surface area of ~2000 m2/g) have shown promising potential for the development of lighter and thinner respirators for protection against toluene.

12 June 2021 in Photochemical & Photobiological Sciences
Verified
Journal Article
Closed access
PDF file
RTRavinder Thaper
Ravinder Thaper
BFBrendan Fagen
Brendan Fagen
JOJonghwa Oh
Jonghwa Oh

27 April 2020 in Workplace Health & Safety
Verified
Journal Article
Closed access
PDF file
HPHolden Phillips
Holden Phillips
JOJonghwa Oh
Jonghwa Oh
Background: The food truck industry has rapidly expanded in the United States and kitchen environments can contain harmful contaminants from cooking emissions. The objective of this study was to examine the levels of aldehydes, polycyclic aromatic hydrocarbons (PAHs), and Particulate Matter (PM)2.5 generated from cooking process in food trucks. Methods: Area sampling was performed twice at two participating food trucks during work shifts. Nine aldehydes and eighteeen PAHs were analyzed according to the relevant standard methods while PM2.5 was measured with a real time monitor. Ventilation performance of the food truck exhaust hoods was also investigated using a thermal anemometer. Findings: Formaldehyde was the only aldehyde detected in all samples with a concentration range of 7.16 to 53.68 µg/m3. No PAHs were detected above the limit of quantification. Average PM2.5 concentrations ranged from 0.65 to 7.03 mg/m3. Food Trucks 1 and 2 have an average exhaust flow rate of 211 and 215 L/s per linear meter of hood, respectively. Conclusions/Application to practice: Overall, Food Truck 2 had consistently higher levels of aldehydes and PM2.5 with comparable ventilation performance as Food Truck 1. The higher exposure levels of Food Truck 2 could possibly be attributed to a larger volume of food orders and the heavy duty cooking equipment with an exhaust flow rate below the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) recommendations. Although more investigations need to be performed, the findings could be used to raise awareness of food truck workers and health practitioners to reduce potential exposure risks.