Edward Rauls

Mr. Edward Rauls

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Applied Energy
Verified
Journal Article
Open access
FSFabian Scheepers
Fabian Scheepers
MSMarkus Stähler
Markus Stähler
ASAndrea Stähler
Andrea Stähler
EREdward Rauls
Edward Rauls
MMMartin Müller
Martin Müller
WLWerner Lehnert
Werner Lehnert

1 February 2020 in Energies
Verified
Journal Article
Open access
PDF file
FSFabian Scheepers
Fabian Scheepers
MSMarkus Stähler
Markus Stähler
HHHintzen Hintzen
Hintzen Hintzen
EREdward Rauls
Edward Rauls
MMMartin Müller
Martin Müller
WLWerner Lehnert
Werner Lehnert
Hydrogen produced in a polymer electrolyte membrane (PEM) electrolyzer must be stored under high pressure. It is discussed whether the gas should be compressed in subsequent gas compressors or by the electrolyzer. While gas compressor stages can be reduced in the case of electrochemical compression, safety problems arise for thin membranes due to the undesired permeation of hydrogen across the membrane to the oxygen side, forming an explosive gas. In this study, a PEM system is modeled to evaluate the membrane-specific total system efficiency. The optimum efficiency is given depending on the external heat requirement, permeation, cell pressure, current density, and membrane thickness. It shows that the heat requirement and hydrogen permeation dominate the maximum efficiency below 1.6 V, while, above, the cell polarization is decisive. In addition, a pressure-optimized cell operation is introduced by which the optimum cathode pressure is set as a function of current density and membrane thickness. This approach indicates that thin membranes do not provide increased safety issues compared to thick membranes. However, operating an N212-based system instead of an N117-based one can generate twice the amount of hydrogen at the same system efficiency while only one compressor stage must be added.

1 March 2022 in Control Engineering Practice
Verified
Journal Article
Open access
RKR. Keller
R. Keller
EREdward Rauls
Edward Rauls
MHM. Hehemann
M. Hehemann
MMM. Müller
M. Müller
MCM. Carmo
M. Carmo

31 August 2019 in Biotechnology Journal
Verified
Journal Article
Open access
PDF file
THTobias Habicher
Tobias Habicher
EREdward Rauls
Edward Rauls
FEFranziska Egidi
Franziska Egidi
TKTimm Keil
Timm Keil
TKTobias Klein
Tobias Klein
JBJochen Büchs
Jochen Büchs
Introducing fed‐batch mode in early stages of development projects is crucial for establishing comparable conditions to industrial fed‐batch fermentation processes. Therefore, cost efficient and easy to use small‐scale fed‐batch systems that can be integrated into existing laboratory equipment and workflows are required. Recently, a novel polymer‐based controlled‐release fed‐batch microtiter plate is described. In this work, the polymer‐based controlled‐release fed‐batch microtiter plate is used to investigate fed‐batch cultivations of a protease producing Bacillus licheniformis culture. Therefore, the oxygen transfer rate (OTR) is online‐monitored within each well of the polymer‐based controlled‐release fed‐batch microtiter plate using a µRAMOS device. Cultivations in five individual polymer‐based controlled‐release fed‐batch microtiter plates of two production lots show good reproducibility with a mean coefficient of variation of 9.2%. Decreasing initial biomass concentrations prolongs batch phase while simultaneously postponing the fed‐batch phase. The initial liquid filling volume affects the volumetric release rate, which is directly translated in different OTR levels of the fed‐batch phase. An increasing initial osmotic pressure within the mineral medium decreases both glucose release and protease yield. With the volumetric glucose release rate as scale‐up criterion, microtiter plate‐ and shake flask‐based fed‐batch cultivations are highly comparable. On basis of the small‐scale fed‐batch cultivations, a mechanistic model is established and validated. Model‐based simulations coincide well with the experimentally acquired data.

4 April 2024 in International Journal of Hydrogen Energy
Verified
Journal Article
Open access
EREdward Rauls
Edward Rauls
MHMichael Hehemann
Michael Hehemann
FSFabian Scheepers
Fabian Scheepers
MMMartin Müller
Martin Müller
RPRalf Peters
Ralf Peters
DSDetlef Stolten
Detlef Stolten

30 October 2019 in Energies
Verified
Journal Article
Open access
PDF file
MMMartin Müller
Martin Müller
WZWalter Zwaygardt
Walter Zwaygardt
EREdward Rauls
Edward Rauls
MHMichael Hehemann
Michael Hehemann
SHStefan Haas
Stefan Haas
MCMarcelo Carmo
Marcelo Carmo
Herein we discuss polymer electrolyte membrane (PEM) electrolysis stacks and systems we developed that are optimized for direct coupling to a photovoltaic (PV) panel. One advantage of PEM systems is their use of non-corrosive and non-toxic media. Thus, safe outdoor operation can be guaranteed, even in the case of a leakage. The system design was adapted to reduce the number of connection tubes, allowing for a series connection of multiple stacks at low cost and high reliability. One coupled PEM/PV system was tested under various temperature and irradiance conditions. All system components were also thoroughly characterized. The characterization was used to calibrate simple models of the individual components. Finally, the models were used to predict the system’s solar-to-hydrogen efficiency under different operating conditions and to find an optimal configuration for real-world outdoor operation.