Xueneng Su

Dr. Xueneng Su


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2019 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
XSXueneng Su
Xueneng Su
CHChuan He
Chuan He
TLTianqi Liu
Tianqi Liu
LWLei Wu
Lei Wu
The rapid expansion in scale of power systems and the emergence of new smart grid technologies continuously increase computational complexity of power system simulations. Graphic processing unit (GPU), which features massive concurrent threads and excellent floating-point performance, brings new opportunities into power system simulations. This paper introduces an advanced GPU-CPU based parallel power flow (PF) approach by adopting vectorization parallelization and sparse techniques. Specifically, the root cause behind sparsity property of PF and its impacts on the first two steps of Newton-Raphson (NR) based PF calculation, i.e., forming nodal power mismatch vector and updating Jacobian matrix, are quantitatively analyzed. Moreover, a novel GPU-CPU based parallel PF approach is presented, which effectively integrates advanced GPU-based vectorization parallelization and sparse techniques to accelerate performance of PF calculations. Numerical studies validate the effectiveness of various customized parallel schemes for individual key steps of the proposed NR-based parallel PF approach.

19 November 2022 in IET Renewable Power Generation
Verified
Journal Article
Open access
XSXueneng Su
Xueneng Su
HZHua Zhang
Hua Zhang
YGYiwen Gao
Yiwen Gao
JZJian Zhang
Jian Zhang
TSTunfang Song
Tunfang Song
The detection of single phase‐earth faults has been a difficult task for a long time due to its very low current in high impedance grounded fault especially in a neutral un‐effectively grounded system. To address this issue, this paper firstly proposes multi‐learner based single phase‐earth fault identification models. First, to erase disturb noise in fault recording profiles, a denoising model is put forward based on the wavelet transform optimized via the proposed threshold improvement approach. Second, feature engineering reflecting local and/or global evolutionary process of fault evolving features is modelled, and in turn two key feature transforming techniques of principal component analysis (PCA) and random forest (RF) are individually employed to recognize the best effective combination of fault feature set. Subsequently, six learners of logistical regression (LR), support vector machine (SVM), K‐neighbor (KN), RF, XGBoost and LightGBM based fault identification models are individually custom‐designed which the feature subset in high priority are fed into. Furthermore, to guide the model optimization, several advanced manners of hyper‐parametric sampling via normal and Chi‐2 distribution, learning curve, validation curve, receiver operation characteristic curve (ROC) are applied. Numerical studies indicates the the high value of the proposed model when applied in engineering practice.

10 October 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ZCZhen Chen
Zhen Chen
XHXiaoyan Han
Xiaoyan Han
CFChengwei Fan
Chengwei Fan
ZHZirun He
Zirun He
XSXueneng Su
Xueneng Su
Shengwei MeiShengwei Mei
Shengwei Mei
In recent years, machine learning methods have shown the great potential for real-time transient stability status prediction (TSSP) application. However, most existing studies overlook the imbalanced data problem in TSSP. To address this issue, a novel data segmentation-based ensemble classification (DSEC) method for TSSP is proposed in this paper. Firstly, the effects of the imbalanced data problem on the decision boundary and classification performance of TSSP are investigated in detail. Then, a three-step DSEC method is presented. In the first step, the data segmentation strategy is utilized for dividing the stable samples into multiple non-overlapping stable subsets, ensuring that the samples in each stable subset are not more than the unstable ones, then each stable subset is combined with the unstable set into a training subset. For the second step, an AdaBoost classifier is built based on each training subset. In the final step, decision values from each AdaBoost classifier are aggregated for determining the transient stability status. The experiments are conducted on the Northeast Power Coordinating Council 140-bus system and the simulation results indicate that the proposed approach can significantly improve the classification performance of TSSP with imbalanced data.

28 January 2024 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
XSXueneng Su
Xueneng Su
HZHua Zhang
Hua Zhang
JZJian Zhang
Jian Zhang
CLCheng Long
Cheng Long
XLXiaopeng Li
Xiaopeng Li
SLShilong Li
Shilong Li
The rapid and accurate identification of single‐phase earth fault is of prime concern for many scholars from industry and academia, because its fault characteristics are extremely weak while the related potential hazard is extremely severe. In this context, this paper borrows from Deep Learning and in turn innovatively puts forward a multilayer perceptron (MLP)‐based single‐phase earth fault detection model augmented with kernel principal component analysis (KPCA). First, KPCA is applied to building fault feature extraction engineering via the transformation of fault features from low‐dimensional linear indivisible space to high‐dimensional one. Second, a MLP‐based model is used for basic model reference where many optimization strategies together with dropout technique are introduced and custom‐designed in tuning this model to achieve the best detection accuracy and convergence characteristic. Numerical studies demonstrate the superiority of the proposed KPCA‐MLP‐based single‐phase earth fault detection model.

25 April 2024 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
HZHua Zhang
Hua Zhang
XSXueneng Su
Xueneng Su
JZJian Zhang
Jian Zhang
CLCheng Long
Cheng Long
XNXin Ning
Xin Ning
RZRui Zhang
Rui Zhang
Over a long time detecting high impedance earth faults (HIEFs) and suppressing the forest fire danger commonly caused by edge-phase-type single phase-earth faults in an ineffectively grounded system are of high concerns. To address this problem, this paper innovatively refines the structure of distribution system via a single-phase power transformer (PT) isolated subnetwork division mode, and optimizes the voltage distribution among three phases by introducing an additional capacitance, which is extremely conducive to control arc ignition commonly occurring in two edge-phases while line-to-line voltage are still equal to the original state. Second, to augment detecting sensitivity in HIEFs, a novel detecting judgement criterion merely using the vector-based variation via pre-fault and post-fault zero-sequence voltage, is theoretically derived, and compared with traditional methodologies it can possess a higher detecting ability. Numerical simulations and real-field tests effectively and fully demonstrate the adaptability and potentials of the proposed structure and approach toward single phase-earth faults.

19 December 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
XSXueneng Su
Xueneng Su
HZHua Zhang
Hua Zhang
In this letter, we propose two new structure designs and their related detection criteria in identifying extremely high impedance earth faults (HIEFs). First, two subnetwork division modes are introduced to limit the coupling flow of zero-sequence current between the faulty line and sound lines where two kinds of power transformers are individually applied. Second, following the quantitative discussions about the effect of the proposed structures on original power grid, e.g., power supply reliability and the probability of bushfire caused by HIEFs, two novel detecting judgement criteria of merely using the vectorized variation of zero-sequence voltage are mathematically formulated. Numerical simulations reveal that in contrast with traditional solutions, the two judgement criteria present more superior and sensitive performance in detecting HIEFs.