M. J. Ruzmyn Vilcassim

Dr. M. J. Ruzmyn Vilcassim

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in Environment International
Verified
Journal Article
Open access
CLChris C. Lim
Chris C. Lim
HKHo Kim
Ho Kim
MVM. J. Ruzmyn Vilcassim
M. J. Ruzmyn Vilcassim
GTGeorge D. Thurston
George D. Thurston
TGTerry Gordon
Terry Gordon
SKSun-Young Kim
Sun-Young Kim
Recent studies have demonstrated that mobile sampling can improve the spatial granularity of land use regression (LUR) models. Mobile sampling campaigns deploying low-cost (<$300) air quality sensors could potentially offer an inexpensive and practical approach to measure and model air pollution concentration levels. In this study, we developed LUR models for street-level fine particulate matter (PM2.5) concentration levels in Seoul, South Korea. 169 h of data were collected from an approximately three week long campaign across five routes by ten volunteers sharing seven AirBeams, a low-cost ($250 per unit), smartphone-based particle counter, while geospatial data were extracted from OpenStreetMap, an open-source and crowd-generated geographical dataset. We applied and compared three statistical approaches in constructing the LUR models - linear regression (LR), random forest (RF), and stacked ensemble (SE) combining multiple machine learning algorithms - which resulted in cross-validation R2 values of 0.63, 0.73, and 0.80, respectively, and identification of several pollution 'hotspots.' The high R2 values suggest that study designs employing mobile sampling in conjunction with multiple low-cost air quality monitors could be applied to characterize urban street-level air quality with high spatial resolution, and that machine learning models could further improve model performance. Given this study design's cost-effectiveness and ease of implementation, similar approaches may be especially suitable for citizen science and community-based endeavors, or in regions bereft of air quality data and preexisting air monitoring networks, such as developing countries.

24 June 2023 in EBioMedicine
Verified
Journal Article
Open access
MVM. J. Ruzmyn Vilcassim
M. J. Ruzmyn Vilcassim
GTGeorge D. Thurston
George D. Thurston
Despite progress in many countries, air pollution, and especially fine particulate matter air pollution (PM2.5) remains a global health threat: over 6 million premature cardiovascular and respiratory deaths/yr. have been attributed to household and outdoor air pollution. In this viewpoint, we identify present gaps in air pollution monitoring and regulation, and how they could be strengthened in future mitigation policies to more optimally reduce health impacts. We conclude that there is a need to move beyond simply regulating PM2.5 particulate matter mass concentrations at central site stations. A greater emphasis is needed on: new portable and affordable technologies to measure personal exposures to particle mass; the consideration of a submicron (PM1) mass air quality standard; and further evaluations of effects by particle composition and source. We emphasize the need to enable further studies on exposure-health relationships in underserved populations that are disproportionately impacted by air pollution, but not sufficiently represented in current studies.

19 November 2014 in Environmental Science & Technology
Verified
Journal Article
Open access
MVM. J. Ruzmyn Vilcassim
M. J. Ruzmyn Vilcassim
GTGeorge D. Thurston
George D. Thurston
RPRichard E. Peltier
Richard E. Peltier
TGTerry Gordon
Terry Gordon
The New York City (NYC) subway is the main mode of transport for over 5 million passengers on an average weekday. Therefore, airborne pollutants in the subway stations could have a significant impact on commuters and subway workers. This study looked at black carbon (BC) and particulate matter (PM2.5) concentrations in selected subway stations in Manhattan. BC and PM2.5 levels were measured in real time using a Micro-Aethalometer and a PDR-1500 DataRAM, respectively. Simultaneous samples were also collected on quartz filters for organic and elemental carbon (OC/EC) analysis and on Teflon filters for gravimetric and trace element analysis. In the underground subway stations, mean real time BC concentrations ranged from 5 to 23 μg/m3, with 1 min average peaks >100 μg/m3, while real time PM2.5 levels ranged from 35 to 200 μg/m3. Mean EC levels ranged from 9 to 12.5 μg/m3. At street level on the same days, the mean BC and PM2.5 concentrations were below 3 and 10 μg/m3, respectively. This study shows that both BC soot and PM levels in NYC’s subways are considerably higher than ambient urban street levels and that further monitoring and investigation of BC and PM subway exposures are warranted.

16 September 2014 in Tobacco Control
Verified
Journal Article
Closed access
PDF file
SZSherry Zhou
Sherry Zhou
MWMichael Weitzman
Michael Weitzman
MVM. J. Ruzmyn Vilcassim
M. J. Ruzmyn Vilcassim
JWJennifer Wilson
Jennifer Wilson
NLNina Legrand
Nina Legrand
TGTerry Gordon
Terry Gordon
Background Hookahs are increasingly being used in the USA and elsewhere. Despite the popularity of hookah bars, there is a paucity of research assessing the health effects of hookah smoke, and although New York City (NYC) bans indoor tobacco smoking, hookah lounges claim that they only use herbal products without tobacco. This study investigated levels of multiple indices of indoor air pollution in hookah bars in NYC. Methods Air samples were collected in 8 hookah bars in NYC. Along with venue characteristics, real-time measurements of fine particulate matter (PM2.5), black carbon (BC), and carbon monoxide (CO), and total gravimetric PM, elemental carbon (EC), organic carbon (OC), and nicotine were collected in 1-2 hour sessions. Results Overall, levels of indoor air pollution increased with increasing numbers of active hookahs smoked. The mean (SD) real time PM2.5 level was 1179.9 (939.4) µg/m3, whereas the filter-based total PM mean was 691.3 (592.6) µg/m3. The mean real time BC level was 4.1 (2.3) µg/m3, OC was 237.9 (112.3) µg/m3, and CO was 32 (16) ppm. Airborne nicotine was present in all studied hookah bars (4.2 (1.5) µg/m3). Conclusions These results demonstrate that despite the ban on smoking tobacco products, at the very least, some NYC hookah bars are serving tobacco-based hookahs, and have elevated concentrations of indoor air pollutants that may present a health threat to visitors and employees. Therefore, there is an urgent need for better air quality monitoring in such establishments and policies to combat this emerging public health threat.

18 March 2023 in Toxics
Verified
Journal Article
Open access
PDF file
MVM. J. Ruzmyn Vilcassim
M. J. Ruzmyn Vilcassim
SSSamuel Stowe
Samuel Stowe
RMRachel Majumder
Rachel Majumder
ASAkila Subramaniam
Akila Subramaniam
RSRachel G. Sinkey
Rachel G. Sinkey
Although combustible cigarette smoking rates have declined in recent years, alternative tobacco product use, particularly electronic cigarette use (“vaping”), has increased among young adults. Recent studies indicate that vaping during pregnancy is on the rise, possibly due to the perception that it is a safer alternative to combustible cigarette smoking. However, e-cigarette aerosols may contain several newer, potentially toxic compounds, including some known developmental toxicants that may adversely impact both the mother and the fetus. However, there is paucity of studies that have examined the effects of vaping during pregnancy. While the adverse perinatal outcomes of cigarette smoking during pregnancy are well established, the specific risks associated with inhaling vaping aerosols during pregnancy requires more research. In this article, we discuss the existing evidence and knowledge gaps on the risks of vaping during pregnancy. Studies that investigate vaping-associated systemic exposure and its effects (i.e., biomarker analyses) and maternal and neonatal clinical health outcomes are needed to reach more robust conclusions. We particularly emphasize the need to go beyond comparative studies with cigarettes, and advocate for research that objectively evaluates the safety of e-cigarettes and other alternative tobacco products.

25 January 2016 in Tobacco Control
Verified
Journal Article
Closed access
PDF file
SZSherry Zhou
Sherry Zhou
LBLeili Behrooz
Leili Behrooz
MWMichael Weitzman
Michael Weitzman
GPGrace Pan
Grace Pan
MVM. J. Ruzmyn Vilcassim
M. J. Ruzmyn Vilcassim
TGTerry Gordon
Terry Gordon
Background Despite the increasing popularity of hookah bars, there is a lack of research assessing the health effects of hookah smoke among employees. This study investigated indoor air quality in hookah bars and the health effects of secondhand hookah smoke on hookah bar workers. Methods Air samples were collected during the work shift of 10 workers in hookah bars in New York City (NYC). Air measurements of fine particulate matter (PM2.5), fine black carbon (BC2.5), carbon monoxide (CO), and nicotine were collected during each work shift. Blood pressure and heart rate, markers of active smoking and secondhand smoke exposure (exhaled CO and saliva cotinine levels), and selected inflammatory cytokines in blood (ineterleukin (IL)-1b, IL-6, IL-8, interferon γ (IFN-γ), tumour necrosis factor (TNF-α)) were assessed in workers immediately prior to and immediately after their work shift. Results The PM2.5 (gravimetric) and BC2.5 concentrations in indoor air varied greatly among the work shifts with mean levels of 363.8 µg/m3 and 2.2 µg/m3, respectively. The mean CO level was 12.9 ppm with a peak value of 22.5 ppm CO observed in one hookah bar. While heart rate was elevated by 6 bpm after occupational exposure, this change was not statistically significant. Levels of inflammatory cytokines in blood were all increased at postshift compared to preshift testing with IFN-Υ increasing from 0.85 (0.13) to 1.6 (0.25) (mean (standard error of the mean; SEM)) pg/mL (p90 ppm exhaled CO. Conclusions These results demonstrate that hookah bars have elevated concentrations of indoor air pollutants that appear to cause adverse health effects in employees. These data indicate the need for further research and a marked need for better air quality monitoring and policies in such establishments to improve the indoor air quality for workers and patrons.