In this Letter, we present a single-step method to simultaneously retrieve x-ray absorption and phase images valid for a broad range of imaging energies and material properties. Our method relies on the availability of spectrally resolved intensity measurements, which is now possible using semiconductor x-ray photon counting detectors. The retrieval method is derived and presented, with results showing good agreement.
In this Letter, we propose the first single-shot, noninterferometric x-ray imaging method for simultaneous retrieval of absorption, phase, and differential-phase imagery with quantitative accuracy. Our method utilizes a photon-counting spectral x-ray detector in conjunction with a simplified transport-of-intensity equation for coded-aperture phase-contrast imaging to efficiently solve the retrieval problem. This method can utilize an incoherent and polychromatic (clinical or laboratory) x-ray tube and can enable retrieval for a wide range and composition of material properties. The proposed method has been validated via computer simulations and is expected to significantly benefit applications that are sensitive to complexity of measurement, radiation dose and imaging time.
Spectral images from photon counting detectors are being explored for material decomposition applications such as for obtaining quantitative maps of tissue types and contrast agents. While these detectors allow acquisition of multi-energy data in a single exposure, separating the total photon counts into multiple energy bins can lead to issues of count starvation and increased quantum noise in resultant maps. Furthermore, the complex decomposition problem is often solved in a single inversion step making it difficult to separate materials with close properties. We propose a multi-step decomposition method which allows solving the problem in multiple steps using the same spectral data collected in a single exposure. During each step, quantitative accuracy of a single material is under focus and one can flexibly optimize the bins chosen in that step. The result thus obtained becomes part of the input data for the next step in the multi-step process. This makes the problem less ill-conditioned and allows better quantitation of more challenging materials within the object. In comparison to a conventional single-step method, we show excellent quantitative accuracy for decomposing up to six materials involving a mix of soft tissue types and contrast agents in micro-CT sized digital phantoms.
11 December 2020 in Journal of the Optical Society of America A
X-ray phase contrast imaging (PCI) combined with phase retrieval has the potential to improve soft-material visibility and discrimination. This work examined the accuracy, image quality gains, and robustness of a spectral phase retrieval method proposed by our group. Spectroscopic PCI measurements of a physical phantom were obtained using state-of-the-art photon-counting detectors in combination with a polychromatic x-ray source. The phantom consisted of four poorly attenuating materials. Excellent accuracy was demonstrated in simultaneously retrieving the complete refractive properties (photoelectric absorption, attenuation, and phase) of these materials. Approximately 10 times higher SNR was achieved in retrieved images compared to the original PCI intensity image. These gains are also shown to be robust against increasing quantum noise, even for acquisition times as low as 1 s with a low-flux microfocus x-ray tube (average counts of 250 photons/pixels). We expect that this spectral phase retrieval method, adaptable to several PCI geometries, will allow significant dose reduction and improved material discrimination in clinical and industrial x-ray imaging applications.
22 October 2018 in IEEE Transactions on Medical Imaging
This paper describes the implementation of a novel and robust threshold energy calibration method for photon counting detectors using polychromatic x-ray tubes. Methods often used for such energy calibration may require re-orientation of the detector or introduce calibration errors that are flux and acquisition time dependent. Our newly proposed “differential intensity ratios” (DIR) method offers a practical and robust alternative to existing methods. We demonstrate this robustness against photon flux used in calibration, spectral errors such as pulse pile-up as well as the detector’s inherent spectral resolution limits. The demonstrated significant insensitivity of the proposed DIR signature to detector spectral distortions and energy resolution is a key finding. The proposed DIR calibration method is demonstrated using Medipix3RX detectors with a CdTe sensor under varying flux conditions. A per pixel calibration using the DIR method has also been implemented to demonstrate an improvement over the global energy resolution of the PCD.