UV/ozone (UVO)-assisted formation of self-assembled monolayer (SAM) of 1H,1H,2H,2H-perfluorodecyltriethoxysilane (PFDS) was prepared on a glass surface. The effect of UVO exposure time on surface roughness and hydrophilicity was investigated through goniometer and atomic force microscope (AFM), and deposition time-dependent SAM quality was detected by AFM and X-ray photoelectron spectroscopy (XPS). The glass surface became smooth with UVO radiation after 10 min, and the hydrophilicity was also improved after the treatment. Confirmed by surface topography detection and chemical composition analysis, a high-quality SAM can be formed rapidly on glass with 10 min UVO treatment followed by 2 h deposition in PFDS solution. Excellent tribological performances of SAM coated with UVO treatment glass were demonstrated by friction and wear tests on AFM compared to film-deposited glass without UVO treatment and original glass. The study sheds a light on preparing high-quality lubrication and antiwear self-assembled films on the surface of engineering materials.
5 November 2020 in Journal of Micromechanics and Microengineering
This paper on the reports design, fabrication and position monitoring of a micro electromagnetic linear actuator. The actuator consists of stator, slider, guide, sensors and affiliated jigs. Actuation is achieved through ampere force between two phase micro-coils (copper) on the stator and permanent magnets (thick NdFeB film) on the slider. During the slider’s movement in the guide slot, tunnelling magneto-resistance (TMR) sensors are utilized to sense the magnetic field to realize position monitoring. TMR is chosen because it owns advantages of small size, large sensitivity and easy integration with micro devices. Purpose of this research is to report the micro fabrication of thick magnet films and testify the possibility of using TMR as position monitoring sensors. Actuators are fabricated by micro-electro-mechanical system process (stator and guide) and precise machining (slider and jigs). Surface magnetic field generated by the slider, driving characteristics of the actuator as well as the position monitoring capabilities of TMR elements are simulated and experimented, respectively. The slider attains 60 mm s −1 speed by sinusoidal input signal at 300 Hz frequency and 0.2 A current magnitude. Actuation bandwidth is between 300 Hz and 500 Hz at open loop condition. The maximum position monitoring error in present work is 2.2% with 101 μ m value for 4.5 mm stroke.
26 November 2020 in Journal of Micromechanics and Microengineering
This paper presents the design, fabrication and characterization of a novel micro electromagnetic linear actuator, which exhibits two highlights: slider self-alignment and self-attachment capability. Such characters are realized by deliberately utilizing the attractive force between the permanent magnets (Nd 2 Fe 14 B) of the slider and nickel ferromagnetic cores embedded in the stator. Actuation is achieved via thrust from both meander micro copper coils and nickel ferromagnetic cores in the stator to the permanent magnets of the slider. The actuator is fabricated by the micro machining process. The surface magnetic property of the slider is simulated and experimentally measured. The eccentric experiment is conducted to evaluate the attraction force between the slider and stator, which proves its self-attachment characteristics. The device is actuated by two-phase sinusoidal currents with a 0.5 A amplitude under an open-loop condition. The slider demonstrates self-alignment movements before moving forward when misalignment occurs. The actuation experimental results show that the average velocity of the slider reaches 4 mm s –1 and 12 mm s –1 at 10 Hz and 30 Hz, respectively. Further increasing the input frequency to 50 Hz leads to the unsteady actuation state, indicating the actuator bandwidth is less than 50 Hz under an open-loop condition.
15 November 2022 in Journal of Micromechanics and Microengineering
This paper introduces the design, fabrication and characterization of a micro electromagnetic linear actuator integrated with magnetic guide. The actuator consists of a slider, a stator and a magnetic guide. A magnetic guide is used to replace the mechanical rail of conventional linear actuator to ensure the linear motion and to avoid friction. The purpose of this paper is to study the influence of magnetic guide on the dynamic characteristics of electromagnetic linear actuator and measuring techniques for micro-actuators. To test the resistance to motion and output thrust force of the actuator, a cantilever type force sensor is proposed, which can measure the small force in ∼mN order, and the measurement error is less than 3%. Using this sensor, the output thrust measured is higher than 10 mN when 1 A current is applied, and the friction force of the actuator measured is about 7.73 mN. Two-phase square wave and sine wave current are used to drive the actuator, the minimum driving current and frequency of the actuator are less than 0.1 A and 1 Hz respectively. The actuator attains a maximum stable moving speed of 0.15 m s −1 with the input signal frequency of below 250 Hz. In addition, the anti-interference capability of the actuator is evaluated through simulations and experiments. These results show that the actuator can bear an interference 45 times its own gravity in the directions that are perpendicular to the moving freedom, and can adjust the direction of motion automatically when the rotation angle in three orthogonal directions is less than 6°.
14 February 2022 in Journal of Micromechanics and Microengineering
This paper presents a bi-stable mechanism, which mainly consists of a suspended mass, a spacer and a bottom plate. Electromagnetic actuation is used for switching between two states (i.e. ‘On/Off’ state). The actuation is achieved via permanent magnet (PM) on the suspended mass and micro-coils embedded in the bottom plate. Different from spiral coil and central core in conventional design, micro-coils in this paper integrate Cu and Ni together as a whole, acting as both coil and ferromagnetic core. This integration simplifies the fabrication into one-mask process. Furthermore, chessboard patterned PM is utilized with Cu-Ni integrated micro-coils to generate enhanced force density. The bi-stable mechanism is designed, fabricated and experimentally characterized. Total size of this mechanism is 16 × 14 × 2 mm 3 . No power is needed for holding either of the state. Switching processes (both ‘On’ to ‘Off’ and ‘Off’ to ‘On’) can be realized with external acceleration of 24 G (gravity) and 37 G, respectively. Furthermore, resetting (i.e. ‘On’ to ‘Off’) can also be accomplished with 1.5 A current input.