Arnold J Wilkins

Prof. Arnold J Wilkins

University of Essex
orcid

Research Focus & Metrics

Academic Career Length

56Years (1971-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 1984 in Brain
Verified
Journal Article
Closed access
PDF file
JAJ. H. P. Aarts
J. H. P. Aarts
CBC.D. Binnie
C.D. Binnie
ASA. M. Smit
A. M. Smit
AWArnold J Wilkins
Arnold J Wilkins
It is well established that generalized epileptiform EEG discharges unaccompanied by overt clinical change may nevertheless be associated with transitory cognitive impairment (TCI) detectable by appropriate psychological testing. However, the tests employed in most research studies of this phenomenon are of little use for routine clinical application. They are suitable for administration only over short periods of time and are therefore applicable only to patients with a high discharge rate, a serious limitation, as the discharges are generally depressed by the tests themselves.

1 January 1987 in Neuropsychologia
Verified
Journal Article
Closed access
AWArnold J Wilkins
Arnold J Wilkins
TST. Shallice
T. Shallice
RMR. McCarthy
R. McCarthy

1 September 2005 in Epilepsia
Verified
Journal Article
Closed access
PDF file
RFRobert S. Fisher
Robert S. Fisher
GHGraham Harding
Graham Harding
GEGiuseppe Erba
Giuseppe Erba
GBGregory L. Barkley
Gregory L. Barkley
AWArnold J Wilkins
Arnold J Wilkins

1 December 1984 in Brain
Verified
Journal Article
Closed access
PDF file
AWArnold J Wilkins
Arnold J Wilkins
INIan Nimmo-Smith
Ian Nimmo-Smith
ATAnne Tait
Anne Tait
CMCHRISTOPHER McMANUS
CHRISTOPHER McMANUS
SSSergio DELLA Sala
Sergio DELLA Sala
SSSydney Scott
Sydney Scott
Certain patterns of stripes are judged to be unpleasant to look at. They include illusions of colour, shape and motion that are sometimes perceived predominantly to one side of fixation. People who suffer frequent headaches tend to report more illusions, and if the pain consistently occurs on the samer side of the head the illusions tend to be lateralized. The parameters of the patterns that induce illusions (including their shape, spatial frequency, duty cycle, contrast and cortical representation) closely resemble those that epileptiform electroencephalographic abnormalities in patients with photosensitive epilepsy. The viewing conditions under which such abnormalities are likely to appear are also those under which more illusions are seen.

1 September 2010
Verified
Conference Paper
Closed access
AWArnold J Wilkins
Arnold J Wilkins
JVJennifer Veitch
Jennifer Veitch
BLBrad Lehman
Brad Lehman
The IEEE Standards Working Group, IEEE PAR1789 “Recommending practices for modulating current in High Brightness LEDs for mitigating health risks to viewers” has been formed to advise the lighting industry, ANSI/NEMA, IEC, EnergyStar and other standards groups about the emerging concern of flicker in LED lighting. This paper introduces power electronic designers for LED lighting to health concerns relating to flicker, demonstrates that existing technologies in LED lighting sometimes provide flicker at frequencies that may induce biological human response, and discusses a few methods to consider when trying to mitigate unintentional biological effects of LED lighting. The paper represents on-going work in IEEE PAR1789 that is vital to designing safe LED lamp drivers.

1 March 1989 in Lighting Research & Technology
Verified
Journal Article
Closed access
PDF file
AWArnold J Wilkins
Arnold J Wilkins
INI. Nimmo-Smith
I. Nimmo-Smith
ASA.I. Slater
A.I. Slater
LBL. Bedocs
L. Bedocs
The weekly incidence of headaches among office workers was compared when the offices were lit by fluorescent lighting where the fluorescent tubes were operated by (a) a conventional switch-start circuit with choke ballast providing illumination that pulsated with a modulation depth of 43-49% and a principal frequency component at 100 Hz; (b) an electronic start circuit with choke ballast giving illumination with similar characteristics; (c) an electronic ballast driving the lamps at about 32 kHz and reducing the 100 Hz modulation to less than 7%. In a double-blind cross-over design, the average incidence of headaches and eyestrain was more than halved under high-frequency lighting. The incidence was unaffected by the speed with which the tubes ignited. Headaches tended to decrease with the height of the office above the ground and thus with increasing natural light. Office occupants chose to switch on the high-frequency lighting for 30% longer on average.