Seung Zhoo Yoon

Seung Zhoo Yoon


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2015 in Journal of International Medical Research
Verified
Journal Article
Open access
YCYoon Ji Choi
Yoon Ji Choi
SLShin Yuong Lee
Shin Yuong Lee
KYKyung-Sook Yang
Kyung-Sook Yang
JPJi-Young Park
Ji-Young Park
SYSeung Zhoo Yoon
Seung Zhoo Yoon
SYSuk Min Yoon
Suk Min Yoon
To evaluate whether polymorphisms in the gamma-aminobutyric acid A receptor α1 subunit (GABRA1) gene influence sleep induction time, bispectral index score (BIS) during sleep induction and the total dose of midazolam required to reach a Ramsay Sedation Assessment Scale (RSAS) score of 4. Patients scheduled for elective orthopaedic surgery were enrolled. All patients received initial doses of 0.02 mg/kg intravenous midazolam. If the RSAS score did not reach 4, an additional 1-mg dose of midazolam was administered. Results were compared among groups of patients with five single-nucleotide polymorphisms (SNPs) in GABRA1: rs4263535, rs980791, rs6556562, rs998754 and rs2279020. A total of 104 patients were evaluated. Polymorphism rs4263535 was associated with the lowest BIS during sedation induction. Multinomial logistic regression analysis demonstrated that polymorphism rs4263535 was significantly associated with the total dose of midazolam required for sedation induction. Polymorphism rs4263535 in GABRA1 intron 4 was associated with deeper sedation by intravenous midazolam. Patients with the A/A rs4263535 genotype required a smaller dose of midazolam.

1 January 2017 in Korean Journal of Anesthesiology
Verified
Journal Article
Open access
PDF file
HHHyub Huh
Hyub Huh
JJJae Seung Jung
Jae Seung Jung
SPSang Jae Park
Sang Jae Park
MPMin Kyung Park
Min Kyung Park
CLChoon Hak Lim
Choon Hak Lim
SYSeung Zhoo Yoon
Seung Zhoo Yoon
Huh H, et al. Korean J Anesthesiol. 2017 Jun;70(3):345-349. https://doi.org/10.4097/kjae.2017.70.3.345

1 January 2014 in Journal of Korean Neurosurgical Society
Verified
Journal Article
Open access
PDF file
YCYoon Ji Choi
Yoon Ji Choi
MKMin Chul Kim
Min Chul Kim
YLYoung Jin Lim
Young Jin Lim
SYSeung Zhoo Yoon
Seung Zhoo Yoon
SYSuk Min Yoon
Suk Min Yoon
HYHei Ryeo Yoon
Hei Ryeo Yoon
Propofol and volatile anesthesia have been associated with metabolic acidosis induced by increased lactate. This study was designed to evaluate changes in pH, base excess (BE), and lactate in response to different anesthetic agents and to characterize propofol infusion-associated lactic acidosis. The medical records of patients undergoing neurosurgical anesthesia between January 2005 and September 2012 were examined. Patients were divided into 2 groups : those who received propofol (total intravenous anesthesia, TIVA) and those who received sevoflurane (balanced inhalation anesthesia, BIA) anesthesia. Propensity analysis was performed (1 : 1 match, n=47), and the characteristics of the patients who developed severe acidosis were recorded. In the matched TIVA and BIA groups, the incidence of metabolic acidosis (11% vs. 13%, p=1) and base excess (p>0.05) were similar. All patients in the TIVA group who developed severe acidosis did so within 4 hours of the initiation of propofol infusion, and these patients improved when propofol was discontinued. The incidence of metabolic acidosis was similar during neurosurgical anesthesia with propofol or sevoflurane. In addition, severe acidosis associated with propofol infusion appears to be reversible when propofol is discontinued.

23 May 2017 in Journal of International Medical Research
Verified
Journal Article
Open access
YCYoon Ji Choi
Yoon Ji Choi
JLJae Kwan Lim
Jae Kwan Lim
JPJeong Jun Park
Jeong Jun Park
HHHyub Huh
Hyub Huh
DKDong-Joo Kim
Dong-Joo Kim
SYSeung Zhoo Yoon
Seung Zhoo Yoon
The efficacy of chlorhexidine- and silver sulfadiazine-coated central venous catheters (CSS-CVC) against catheter-related infection remains controversial. We hypothesized that the loss of silver nanoparticles may reduce the antibacterial efficacy of CSS-CVCs and that this loss could be due to the frictional force between the surface of the CVC and the bloodstream. The objective of this study was to investigate whether the antimicrobial effect of CSS-CVCs decreases with increasing exposure time in a bloodstream model and quantitatively assay the antimicrobial effect of CSS-CVCs compared with polyurethane and antiseptic-impregnated CVCs. Each CVC was subjected to 120 hours of saline flow and analyzed at intervals over 24 hours. The analyses included energy-dispersive X-ray spectroscopy, scanning electron microscopy, and optical density after a Staphylococcus aureus incubation test. The weight percentage of silver in the CSS-CVCs significantly decreased to 56.18% (44.10% ± 3.32%) with 48-hour catheterization and to 18.88% (14.82% ± 1.33%) with 120-hour catheterization compared with the initial weight percentage (78.50% ± 6.32%). In the S. aureus incubation test, the antibacterial function of CSS-CVCs was lost after 48 hours [3 (N/D) of OD]. Similar results were observed in a pilot clinical study using 18 CSS-CVCs. We found that the efficacy of CSS-CVCs decreased over time and that the antibacterial function was lost after 48 hours of simulated wear-out. Therefore, antibiotic-impregnated CVCs may be a better option when longer (>48 hours) indwelling is needed.

1 January 2020 in Transplantation Proceedings
Verified
Journal Article
Open access
HRHyun-Su Ri
Hyun-Su Ri
YCYoon Ji Choi
Yoon Ji Choi
JPJu Yeon Park
Ju Yeon Park
SJSejong Jin
Sejong Jin
YLYoon Sook Lee
Yoon Sook Lee
TLTae Beom Lee
Tae Beom Lee
The preoperative elevation of ammonia may be associated with postoperative neurologic complications. The aim of this study was to evaluate the effect of preoperative ammonia level on the incidence of delirium in patients after liver transplantation (LT). Patients (n = 260) who received LT from January 2010 to July 2017 in a single university hospital were retrospectively reviewed. The patients' demographic data, perioperative managements, and postoperative complications were assessed. Patients were divided into the following 2 groups: those who had a preoperative elevation (Group A, n = 158) and those with a normal range (Group C, n = 102). The cut-off value for a normal serum ammonia level in our hospital was defined as 32 μg/dL. After propensity score matching, there was no difference in the incidence of delirium between the groups (P = .784). Delirium occurred in 8 of 68 (11.76%) patients in Group A and 7 of 68 (10.29%) patients in Group C after LT. In addition, there was no difference in the incidence of delirium between the groups, even patients were categorized based on serum ammonia levels into 3 groups as follows: < 32 μg/dL (28/158 [17.72%]), 32 to 65 μg/dL (28/158 [17.72%]), and >65 μg/dL (28/158 [17.72%]) (P = .134). The preoperative serum ammonia level was not related with the incidence of postoperative delirium. The high elevation group, especially those with greater than 65 μg/dL of preoperative ammonia, was also not related with the incidence of delirium. However, our study is limited by its retrospective design, so future prospective studies are needed.

1 June 2017 in Medicine
Verified
Journal Article
Open access
PDF file
YCYoon Ji Choi
Yoon Ji Choi
SMSam Hong Min
Sam Hong Min
JPJeong Jun Park
Jeong Jun Park
JCJang Eun Cho
Jang Eun Cho
SYSeung Zhoo Yoon
Seung Zhoo Yoon
SYSuk Min Yoon
Suk Min Yoon
For patients undergoing general anesthesia, adequate warming and humidification of the inspired gases is very important. The aim of this study was to evaluate the differences in the heat and moisture content of the inspired gases with low-flow anesthesia using 4 different anesthesia machines. The patients were divided into 11 groups according to the anesthesia machine used (Ohmeda, Excel; Avance; Dräger, Cato; and Primus) and the fresh gas flow (FGF) rate (0.5, 1, and 4 L/min). The temperature and absolute humidity of the inspired gas in the inspiratory limbs were measured at 5, 10, 15, 30, 45, 60, 75, 90, 105, and 120 minutes in 9 patients scheduled for total thyroidectomy or cervical spine operation in each group. The anesthesia machines of Excel, Avance, Cato, and Primus did not show statistically significant changes in the inspired gas temperatures over time within each group with various FGFs. They, however, showed statistically significant changes in the absolute humidity of the inspired gas over time within each group with low FGF anesthesia (P < .05). The anesthesia machines of Cato and Primus showed statistically significant changes in the absolute humidity of the inspired gas over time within each group with an FGF of 4 L/min (P < .05). However, even with low-flow anesthesia, the temperatures and absolute humidities of the inspired gas for all anesthesia machines were lower than the recommended values. There were statistical differences in the provision of humidity among different anesthesia workstations. The Cato and Primus workstations were superior to Excel and Avance. However, even these were unsatisfactory in humans. Therefore, additional devices that provide inspired gases with adequate heat and humidity are needed for those undergoing general anesthetic procedures.