Matlou Ingrid Ingrid Mokgobu

Prof. Matlou Ingrid Ingrid Mokgobu


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
OMOyewale Morakinyo
Oyewale Morakinyo
MMMatlou Ingrid Ingrid Mokgobu
Matlou Ingrid Ingrid Mokgobu
MMMurembiwa Stanley Mukhola
Murembiwa Stanley Mukhola
PHPaul Hunter
Paul Hunter
Particulate matter (PM) is a key indicator of air pollution and a significant risk factor for adverse health outcomes in humans. PM is not a self-contained pollutant but a mixture of different compounds including chemical and biological fractions. While several reviews have focused on the chemical components of PM and associated health effects, there is a dearth of review studies that holistically examine the role of biological and chemical components of inhalable and respirable PM in disease causation. A literature search using various search engines and (or) keywords was done. Articles selected for review were chosen following predefined criteria, to extract and analyze data. The results show that the biological and chemical components of inhalable and respirable PM play a significant role in the burden of health effects attributed to PM. These health outcomes include low birth weight, emergency room visit, hospital admission, respiratory and pulmonary diseases, cardiovascular disease, cancer, non-communicable diseases, and premature death, among others. This review justifies the importance of each or synergistic effects of the biological and chemical constituents of PM on health. It also provides information that informs policy on the establishment of exposure limits for PM composition metrics rather than the existing exposure limits of the total mass of PM. This will allow for more effective management strategies for improving outdoor air quality.

OMOyewale Morakinyo
Oyewale Morakinyo
MMMurembiwa Stanley Mukhola
Murembiwa Stanley Mukhola
MMMatlou Ingrid Ingrid Mokgobu
Matlou Ingrid Ingrid Mokgobu
Particulate matter of aerodynamic diameter of less than 2.5 µm (PM2.5) is a recognised carcinogen and a priority air pollutant owing to its respirable and toxic chemical components. There is a dearth of information in South Africa on cancer and non-cancer risks of exposure to heavy metal (HM) content of PM2.5. This study determined the seasonal concentration of HM in PM2.5 and the cancer and non-cancer risks of exposure to HM in PM2.5. Ambient PM2.5 was monitored and samples were collected during the winter and summer months in an industrialized area in South Africa. Concentration levels of nine HMs—As, Cu, Cd, Cr, Fe, Mn, Ni, Pb, and Zn—were determined in the PM2.5 samples using inductive coupled optical emission spectrophotometry. The non-cancer and cancer risks of each metal through the inhalation, ingestion and dermal routes were estimated using the Hazard Quotient and Excess Lifetime Cancer Risk (ELCR), respectively, among infants, children, and adults. Mean concentration of each HM-bound PM2.5 was higher in winter than in summer. The probability of the HM to induce non-cancer effects was higher during winter than in summer. The mean ELCR for HMs in PM2.5 (5.24 × 10−2) was higher than the acceptable limit of 10−6 to 10−4. The carcinogenic risk from As, Cd, Cr, Ni, and Pb were higher than the acceptable limit for all age groups. The risk levels for the carcinogenic HMs followed the order: Cr > As > Cd > Ni > Pb. The findings indicated that the concentrations of HM in PM2.5 demonstrated a season-dependent pattern and could trigger cancer and non-cancer health risks. The formulation of a regulatory standard for HM in South Africa and its enforcement will help in reducing human exposure to HM-bound PM2.5.

16 July 2020 in Atmosphere
Verified
Journal Article
Open access
PDF file
OMOyewale Morakinyo
Oyewale Morakinyo
MMMurembiwa Stanley Mukhola
Murembiwa Stanley Mukhola
MMMatlou Ingrid Ingrid Mokgobu
Matlou Ingrid Ingrid Mokgobu
Urban air pollution from gaseous pollutants is a growing public health problem in many countries including South Africa. Examining the levels, trends and health risk of exposure to ambient gaseous pollutants will assist in understanding the effectiveness of existing control measures and plan for suitable management strategies. This study determined the concentration levels and non-cancer risk of CO, SO2, NO2, and O3 at an industrial area in Pretoria West, South Africa. We utilised a set of secondary data for CO, NO2, SO2, and O3 that was obtained from a monitoring station. Analysis of the hourly monitored data was done. Their non-cancer risk (HQ) was determined using the human health risk assessment model for different age categories. The annual levels of NO2 (39.442 µg/m3), SO2 (22.464 µg/m3), CO (722.003 µg/m3) and the 8-hour concentration of CO (649.902 µg/m3) and O3 (33.556 µg/m3) did not exceed the South African National Ambient Air Quality Standards for each pollutant. The HQ for each pollutant across exposed groups (except children) was less than 1. This indicates that the recorded levels could not pose non-cancer risk to susceptible individuals.

OMOyewale Morakinyo
Oyewale Morakinyo
MMMatlou Ingrid Ingrid Mokgobu
Matlou Ingrid Ingrid Mokgobu
MMMurembiwa Stanley Mukhola
Murembiwa Stanley Mukhola
TGTshifhiwa Godobedzha
Tshifhiwa Godobedzha
There is a growing concern that exposure to particulate matter of aerodynamic diameter of less than 2.5 µm (PM2.5) with biological composition (bioaerosols) may play a key role in the prevalence of adverse health outcomes in humans. This study determined the bacterial and fungal concentrations in PM2.5 and their inhalation health risks in an industrial vicinity in South Africa. Samples of PM2.5 collected on a 47-mm glass fiber filter during winter and summer months were analysed for bacterial and fungal content using standard methods. The health risks from inhalation of bioaerosols were done by estimating the age-specific dose rate. The concentration of bacteria (168–378 CFU/m3) was higher than fungi (58–155 CFU/m3). Bacterial and fungal concentrations in PM2.5 were lower in winter than in the summer season. Bacteria identified in summer were similar to those identified in winter: Staphylococcus sp., Bacillus sp., Micrococcus sp., Flavobacterium sp., Klebsiella sp. and Pseudomonas sp. Moreover, the fungal floras identified include Cladosporium spp., Aspergillus spp., Penicillium spp., Fusarium spp. and Alternaria spp. Children inhaled a higher dose of bacterial and fungal aerosols than adults. Bacteria and fungi are part of the bioaerosol components of PM2.5. Bioaerosol exposure may present additional health risks for children.

12 March 2021 in Toxins
Verified
Journal Article
Open access
PDF file
MMMatodzi Michael Mokoena
Matodzi Michael Mokoena
LMLutendo Sylvia Mudau
Lutendo Sylvia Mudau
MMMatlou Ingrid Ingrid Mokgobu
Matlou Ingrid Ingrid Mokgobu
MMMurembiwa Stanley Mukhola
Murembiwa Stanley Mukhola
Most conventional water treatment plants are not sufficiently equipped to treat both intracellular and extracellular Microcystins in drinking water. However, the effectiveness of sodium hypochlorite in removing Microcystin in containers at the point-of-use is not yet known. This study aimed to assess point-of-use water container treatment using bleach or sodium hypochlorite (NaOCl) and to assess the health problems associated with microcystins. Thirty-nine percent (29 of 74) of the total selected households were randomly selected to receive and treat their stored container water with sodium hypochlorite. The level of microcystin in the container water was measured after 30 min of contact with sodium hypochlorite. Microcystin concentrations in both the blooming and decaying seasons were higher (mean 1.10, 95% CI 0.46–1.67 µg/L and mean 1.14, 95% CI 0.65–1.63 µg/L, respectively) than the acceptable limit of 1 µg/L in households that did not treat their water with NaOCl, whilst in those that did, there was a significant reduction in the microcystin concentration (mean 0.07, 95% CI 0.00–0.16 µg/L and mean 0.18, 95% CI 0.00–0.45 µg/L). In conclusion, sodium hypochlorite treatment decreased microcystin s to an acceptable level and reduced the related health problems.

Lindokuhle C. RadebeLindokuhle C. Radebe
Lindokuhle C. Radebe
MMMatlou Ingrid Ingrid Mokgobu
Matlou Ingrid Ingrid Mokgobu
GMGomotsegang Molelekwa
Gomotsegang Molelekwa
MMMatodzi Michael Mokoena
Matodzi Michael Mokoena
This study assessed the status of water, sanitation, and hygiene (WASH) services at (49) selected primary schools in uMfolozi Local Municipality, which is situated in the province of Kwa-Zulu Natal in South Africa. Data were collected using an observational checklist tool and by conducting a walk-through survey to inspect the conditions of sanitary facilities, observe the hand-washing practices of the school learners, and analyse the accessibility to safe drinking water in school premises. The data were analysed with the Statistical Package for Social Science Version 29. This study revealed that there is easy access to safe drinking water in all but one school. The dependability of the water supply seemed to be one of the most urgent problems in every school, even though all of them have some kind of drinking water infrastructure on their grounds. Municipal water (n = 25, 36%) and rainwater (n = 25, 36%) were the most common type of water used in schools compared to borehole (n = 15, 22%) and tanker truck water (n = 4, 6%). Schools must have a reserved water supply because of the inconsistent supply of municipal water, and because rainwater is a seasonal harvest while borehole water may be affected by factors like load-shedding. The UNICEF-described ratio of one tap or disperser per fifty learners suggests that the water taps in the schoolyard were insufficient in some schools (n = 25, 36%). Rainwater is collected through a gutter system in the school building roofs and stored in 5000–10,000 Jojo tanks. Borehole water is pumped into Jojo tanks at an elevated position where it is stored, and learners receive the water through taps connected to the borehole tanks. During an emergency when there is no water supply from other sources, tanker trucks are hired to fill tanks that are also used to store rainwater. The borehole and rainwater quality appeared to be clear, but water treatment had not been performed, and the microbial quality was unknown. This shows that the Sustainable Development Goal (SGD) 6, clean water and sanitation, is still far from being met. According to national norms and standards for domestic water and sanitation services, people who do not use water treatment or purification techniques fall in the ‘no service’ category and contribute to the water backlog. Pit latrines (n = 46, 94%) and flush toilet (n = 3, 6%) were found to be the only convenient toilet systems used. The number of toilets is not sufficient according to the guidelines. There are (n = 46, 94%) of the schools in the study area using pit latrine due to insufficient or no water supply. In 89.8% of primary schools, sanitation facilities are in working condition in terms of repair and hygiene, while 10.2% are not usable in terms of hygiene, and these are mostly boy’s toilets. All schools (n = 46, 94%) that have flush toilets is because they received sponsorship from non-government stakeholders that funded them in achieving piped water systems that permit the functionality of flush toilets. For the purposes of this study, hygiene was evaluate based on the items found in toilets and handwashing practices. The hygiene aspects of toilets included tissues, cleanness, and toilet seat. For handwashing practices we looked the number of washing basins, the colour of water, and having soaps to use. In the schools that did provide handwashing facilities, some of the toilets were broken, there was no water, or there was no drainage system in place to allow them to function. However, according to the school act, the handwash basins should be inside the facilities. A total of (n = 7, 14%) of handwash basins were inside the toilets. Only (n = 2, 4%) of schools had handwashing facilities which were Jojo tanks with taps near toilets, which were outside of the toilet, with no soap provided. Additionally, (n = 40, 82%) of learners used drinking points for handwashing, which can possibly transmit microbes among them. The findings revealed that, in general, (n = 32, 64%) of school toilets were clean, while, in general, the girls’ toilets were cleaner than the boys’ toilets. In all the schools, the cleaning services were from the people who were involved in school nutrition. In conclusion, there were water sources available for access to water inside schools; however, the situation can be improved by increasing the number of water source points. Pit latrines were the main used toilets, which were in a majority of the schools, and did not have the necessary terms for hygiene such as handwashing basin, tissues, and others. The lack of the main aspect, i.e., access to water and sanitation items, results in an impact on hygiene to learners as they will fail to practice proper hygiene. However, improvement can still be made by keeping the boys’ toilets clean while increasing the number of handwashing basins inside the toilets, so that they do not use taps outside the toilets. Schools should work towards meeting the required number of handwashing basins to increase access to handwashing facilities.