It is generally accepted that human bipedal upright stance is achieved by feedback mechanisms that generate an appropriate corrective torque based on body-sway motion detected primarily by visual, vestibular, and proprioceptive sensory systems. Because orientation information from the various senses is not always available (eyes closed) or accurate (compliant support surface), the postural control system must somehow adjust to maintain stance in a wide variety of environmental conditions. This is the sensorimotor integration problem that we investigated by evoking anterior-posterior (AP) body sway using pseudorandom rotation of the visual surround and/or support surface (amplitudes 0.5–8°) in both normal subjects and subjects with severe bilateral vestibular loss (VL). AP rotation of body center-of-mass (COM) was measured in response to six conditions offering different combinations of available sensory information. Stimulus-response data were analyzed using spectral analysis to compute transfer functions and coherence functions over a frequency range from 0.017 to 2.23 Hz. Stimulus-response data were quite linear for any given condition and amplitude. However, overall behavior in normal subjects was nonlinear because gain decreased and phase functions sometimes changed with increasing stimulus amplitude. “Sensory channel reweighting” could account for this nonlinear behavior with subjects showing increasing reliance on vestibular cues as stimulus amplitudes increased. VL subjects could not perform this reweighting, and their stimulus-response behavior remained quite linear. Transfer function curve fits based on a simple feedback control model provided estimates of postural stiffness, damping, and feedback time delay. There were only small changes in these parameters with increasing visual stimulus amplitude. However, stiffness increased as much as 60% with increasing support surface amplitude. To maintain postural stability and avoid resonant behavior, an increase in stiffness should be accompanied by a corresponding increase in damping. Increased damping was achieved primarily by decreasing the apparent time delay of feedback control rather than by changing the damping coefficient (i.e., corrective torque related to body-sway velocity). In normal subjects, stiffness and damping were highly correlated with body mass and moment of inertia, with stiffness always about 1/3 larger than necessary to resist the destabilizing torque due to gravity. The stiffness parameter in some VL subjects was larger compared with normal subjects, suggesting that they may use increased stiffness to help compensate for their loss. Overall results show that the simple act of standing quietly depends on a remarkably complex sensorimotor control system.
Upright stance in humans is inherently unstable, requiring corrective action based on spatial-orientation information from sensory systems. One might logically predict that environments providing access to accurate orientation information from multiple sensory systems would facilitate postural stability. However, we show that, after a period in which access to accurate sensory information was reduced, the restoration of accurate information disrupted postural stability. In eyes-closed trials, proprioceptive information was altered by rotating the support surface in proportion to body sway (support surface “sway-referencing”). When the support surface returned to a level orientation, most subjects developed a transient 1-Hz body sway oscillation that differed significantly from the low-amplitude body sway typically observed during quiet stance. Additional experiments showed further enhancement of the 1-Hz oscillation when the surface transitioned from a sway-referenced to a reverse sway-referenced motion. Oscillatory behavior declined with repetition of trials, suggesting a learning effect. A simple negative feedback-control model of the postural control system predicted the occurrence of this 1-Hz oscillation in conditions where too much corrective torque is generated in proportion to body sway. Model simulations were used to distinguish between two alternative explanations for the excessive corrective torque generation. Simulation results favor an explanation based on the dynamic reweighting of sensory contributions to postural control rather than a load-compensation mechanism that scales torque in proportion to a fixed combination of sensory-orientation information.
The Nintendo Wii balance board (WBB) has generated significant interest in its application as a postural control measurement device in both the clinical and (basic, clinical, and rehabilitation) research domains. Although the WBB has been proposed as an alternative to the “gold standard” laboratory-grade force plate, additional research is necessary before the WBB can be considered a valid and reliable center of pressure (CoP) measurement device. In this study, we used the WBB and a laboratory-grade AMTI force plate (AFP) to simultaneously measure the CoP displacement of a controlled dynamic load, which has not been done before. A one-dimensional inverted pendulum was displaced at several different displacement angles and load heights to simulate a variety of postural sway amplitudes and frequencies (<1 Hz). Twelve WBBs were tested to address the issue of inter-device variability. There was a significant effect of sway amplitude, frequency, and direction on the WBB’s CoP measurement error, with an increase in error as both sway amplitude and frequency increased and a significantly greater error in the mediolateral (ML) (compared to the anteroposterior (AP)) sway direction. There was no difference in error across the 12 WBB’s, supporting low inter-device variability. A linear calibration procedure was then implemented to correct the WBB’s CoP signals and reduce measurement error. There was a significant effect of calibration on the WBB’s CoP signal accuracy, with a significant reduction in CoP measurement error (quantified by root-mean-squared error) from 2–6 mm (before calibration) to 0.5–2 mm (after calibration). WBB-based CoP signal calibration also significantly reduced the percent error in derived (time-domain) CoP sway measures, from −10.5% (before calibration) to −0.05% (after calibration) (percent errors averaged across all sway measures and in both sway directions). In this study, we characterized the WBB’s CoP measurement error under controlled, dynamic conditions and implemented a linear calibration procedure for WBB CoP signals that is recommended to reduce CoP measurement error and provide more reliable estimates of time-domain CoP measures. Despite our promising results, additional work is necessary to understand how our findings translate to the clinical and rehabilitation research domains. Once the WBB’s CoP measurement error is fully characterized in human postural sway (which differs from our simulated postural sway in both amplitude and frequency content), it may be used to measure CoP displacement in situations where lower accuracy and precision is acceptable.
22 April 2003 in IEEE Engineering in Medicine and Biology Magazine
Insights are provided by simple closed-loop models of human postural control. In developing a quantitative model to help us understand the postural control system, one might be tempted to capture as much of the complexity as is known about each of the subsystems. However, this article will follow the approach of Occam's Razor. That is, we begin with the simplest possible representation of each of the subsystems and only add complexity as necessary to be consistent with experimental data. For example, a control model with PD control and a positive force feedback loop provides a better explanation of the low-frequency dynamic behavior than the PID control model. Since both models have the same number of parameters, Occam's Razor favors the positive force feedback model over the PID model or any variation on the PID model that includes additional parameters. While there is some experimental evidence that positive force feedback plays a role in some aspects of motor control its contribution to postural control is unknown. Our model that includes positive force feedback represents a quantitative hypothesis that motivates additional experiments to confirm, or refute the contribution of positive force feedback to human postural control and to investigate the dynamic properties of this feedback loop. An important feature clearly revealed by the model-based interpretation of experimental data is the ability of the human postural control system to alter its source of sensory orientation cues as environmental conditions change. Our relatively simple models allowed us to apply systems identification methods in order to estimate the relative contributions (sensory weights) of various sensory orientation cues in different environmental conditions However, our simple models do not predict how the sensory weights should change as a function of environmental conditions or provide insight into the neural mechanisms that cause these changes.
The control of upper body (UB) orientation relative to the pelvis in the frontal plane was characterized by analyzing responses to external perturbations consisting of continuous pelvis tilts (eyes open [EO] and eyes closed [EC]) and visual surround tilts (EO) at various amplitudes. Lateral sway of the lower body was prevented on all tests. UB sway was analyzed by calculating impulse–response functions (IRFs) and frequency–response functions (FRFs) from 0.023 to 10.3 Hz for pelvis tilt tests and FRFs from 0.041 to 1.5 Hz for visual tests. For pelvis tilt tests, differences between FRFs were limited to frequencies <3 Hz and were dependent on stimulus amplitude. IRFs were nearly identical across all pelvis tilt tests for the first 0.2 s, but showed amplitude-dependent changes in their time course at longer time lags. The availability of visual orientation cues (EO vs. EC) had only a small effect on the UB sway during pelvis tilt tests. This small effect of vision was consistent with the small UB sway evoked on visual tilt tests. Experimental results were interpreted using a feedback model of UB orientation control that included time-delayed sensory integration, short-latency reflexive mechanisms, and intrinsic biomechanical properties of the UB. Variation in model parameters indicated that subjects shifted toward reliance on vestibular information and away from proprioceptive information as pelvis tilt amplitudes increased. For visual tilt stimuli, model parameters indicated that subjects shifted toward reliance on vestibular and proprioceptive information and away from visual information as the stimulus amplitude increased.