Francesca De Angelis

Prof. Francesca De Angelis

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 December 2017 in Journal of Nanobiotechnology
Verified
Journal Article
Open access
PDF file
ABAgnese Bregnocchi
Agnese Bregnocchi
EZElena Zanni
Elena Zanni
DUDaniela Uccelletti
Daniela Uccelletti
Fabrizio MarraFabrizio Marra
Fabrizio Marra
DCDomenico Cavallini
Domenico Cavallini
Maria Sabrina  SartoMaria Sabrina Sarto
Maria Sabrina Sarto
Secondary caries are considered the main cause of dental restoration failure. In this context, anti-biofilm and bactericidal properties are desired in dental materials against pathogens such as Streptococcus mutans. To this purpose, graphene based materials can be used as fillers of polymer dental adhesives. In this work, we investigated the possibility to use as filler of dental adhesives, graphene nanoplatelets (GNP), a non toxic hydrophobic nanomaterial with antimicrobial and anti-biofilm properties. Graphene nanoplatelets have been produced starting from graphite intercalated compounds through a process consisting of thermal expansion and liquid exfoliation. Then, a dental adhesive filled with GNPs at different volume fractions has been produced through a solvent evaporation method. The rheological properties of the new experimental adhesives have been assessed experimentally. The adhesive properties have been tested using microtensile bond strength measurements (µ-TBS). Biocidal activity has been studied using the colony forming units count (CFU) method. The anti-biofilm properties have been demonstrated through FE-SEM imaging of the biofilm development after 3 and 24 h of growth. A significantly lower vitality of S. mutans cells has been demonstrated when in contact with the GNP filled dental adhesives. Biofilm growth on adhesive-covered dentine tissues demonstrated anti-adhesion properties of the produced materials. µ-TBS results demonstrated no significant difference in µ-TBS between the experimental and the control adhesive. The rheology tests highlighted the necessity to avoid low shear rate regimes during adhesive processing and application in clinical protocol, and confirmed that the adhesive containing the 0.2%wt of GNPs possess mechanical properties comparable with the ones of the control adhesive.

FAFrancesca De Angelis
Francesca De Angelis
NPNicola Pranno
Nicola Pranno
ALESSIO FRANCHINAALESSIO FRANCHINA
ALESSIO FRANCHINA
Stefano Di CarloStefano Di Carlo
Stefano Di Carlo
Edoardo BraunerEdoardo Brauner
Edoardo Brauner
Luigi Vito StefanelliLuigi Vito Stefanelli
Luigi Vito Stefanelli
Background: Artificial intelligence (AI) has taken hold in public health because more and more people are looking to make a diagnosis using technology that allows them to work faster and more accurately, reducing costs and the number of medical errors. Methods: In the present study, 120 panoramic X-rays (OPGs) were randomly selected from the Department of Oral and Maxillofacial Sciences of Sapienza University of Rome, Italy. The OPGs were acquired and analyzed using Apox, which takes a panoramic X-rayand automatically returns the dental formula, the presence of dental implants, prosthetic crowns, fillings and root remnants. A descriptive analysis was performed presenting the categorical variables as absolute and relative frequencies. Results: In total, the number of true positive (TP) values was 2.195 (19.06%); true negative (TN), 8.908 (77.34%); false positive (FP), 132 (1.15%); and false negative (FN), 283 (2.46%). The overall sensitivity was 0.89, while the overall specificity was 0.98. Conclusions: The present study shows the latest achievements in dentistry, analyzing the application and credibility of a new diagnostic method to improve the work of dentists and the patients’ care.

Gabriella GalluccioGabriella Galluccio
Gabriella Galluccio
ASAdriana A. De Stefano
Adriana A. De Stefano
MHMartina Horodynski
Martina Horodynski
AIAlessandra Impellizzeri
Alessandra Impellizzeri
Rosanna GuarnieriRosanna Guarnieri
Rosanna Guarnieri
FAFrancesca De Angelis
Francesca De Angelis
The aim of this work was to evaluate the efficacy and accuracy of maxillary arch transverse expansion using the Invisalign® clear aligner system without auxiliaries other than Invisalign attachments. Knowing the accuracy of a movement through a clear aligner system allows the clinician to plan the treatment with greater precision and to achieve the expected result faster. The study group included 28 patients with a mean age of 17 ± 3.2 years. The treatment protocol for all the selected patients included the application of the Invisalign® clear aligner system without auxiliaries, except for the Invisalign® attachments; in no case were tooth extraction or interproximal enamel reduction (IPR) performed. Linear measurements of the expansion were assessed before treatment (T0), at the end of treatment (T1), and on final virtual models by ClinCheck® (TC). A paired t-test was used to compare T0-T1 and T1-TC differences. A paired t-test was applied, and one normality was validated with the Shapiro–Wilks test. If normality was not met, the nonparametric test (Mann–Whitney U test) was applied. The level of significance was set at 5%. Statistically significant differences were found for all measurements at T0-T1. The results showed an average accuracy of efficacy of 70.88%. The differences in predictability between the various vestibular measurements (intercanine, inter-premolar, and intermolar) were not statistically significant, while they were for gingival measurements. The overall accuracy of the expansion treatment was 70%, regardless of tooth type.

Luigi Vito StefanelliLuigi Vito Stefanelli
Luigi Vito Stefanelli
ALESSIO FRANCHINAALESSIO FRANCHINA
ALESSIO FRANCHINA
Andrea PrannoAndrea Pranno
Andrea Pranno
Gerardo PellegrinoGerardo Pellegrino
Gerardo Pellegrino
AFAgnese Ferri
Agnese Ferri
FAFrancesca De Angelis
Francesca De Angelis
Objectives: The use of digital devices is strongly influencing the dental rehabilitation workflow both for single-crown rehabilitation and for full-arch prosthetic treatments. Methods: In this study, trueness was analyzed by overlapping the scan dataset made with Medit I-500 (by using two different tips and two different scan strategies) with the scan dataset made with lab scanning, and the values of the (90°–10°)/2 method were reported. Precision was evaluated by using the same values of trueness coming from the intra-group overlapping (scan dataset made with an IOS overlapped and compared to each other). Moreover, two different software programs of overlapping were used to calculate accuracy values. Results: The mean difference of trueness was 26.61 ± 5.07 µm with the suggested strategy of intraoral scanning and using a new design of the tip, 37.99 ± 4.94 µm with the suggested strategy of intraoral scanning and using the old design of the tip, and 51.22 ± 6.57 µm with a new strategy of intraoral scanning and using the old design of the tip. The mean difference of precision was 23.57 ± 5.77 µm with the suggested strategy of intraoral scanning and using a new design of the tip, 38.34 ± 11.39 µm with the suggested strategy of intraoral scanning and using the old design of the tip, and 46.93 ± 7.15 µm with a new strategy of intraoral scanning and using the old design of the tip. No difference was found in the trueness and precision data extracted using the two different programs of superimposition Geomagic Control X and Medit Compare. Conclusions: The outcomes of this study showed that the latest version of I-Medit 500 with the use of a new tip seems to be promising in terms of accuracy when a full arch needs to be scanned. Moreover, Medit Compare, which is an application of Medit IOS software, can be used to calculate IOS accuracy.

Luigi Vito StefanelliLuigi Vito Stefanelli
Luigi Vito Stefanelli
GMGeorge A. Mandelaris
George A. Mandelaris
ALESSIO FRANCHINAALESSIO FRANCHINA
ALESSIO FRANCHINA
NPNicola Pranno
Nicola Pranno
MPMichele Pagliarulo
Michele Pagliarulo
Stefano Di CarloStefano Di Carlo
Stefano Di Carlo
A minimally invasive implant treatment approach for future full arch implant prosthetic rehabilitations of trophic jaws represents a challenge. An optimal implant planning is strongly related with an accurate merge of the prosthetic information and the radiographic data. To comply with that, most computer aided implantology (CAI) systems require additional steps, as radiographic stents or fiducial markers to overlap digital jaw scans to cone beam computed tomography (CBCT) data. Using dynamic CAI, residual teeth (up to three) make it possible for the merge to avoid new radiographic scans. An additional challenge is the treatment involving immediate implants compared with delayed implants placed into healed bone. As for other static CAI systems, the operator’s experience and the quality of the CBCT data make the planning affordable and secure the entire implants placement procedure. The literature reports accuracies in terms of comparison between placed implants and planned implants, following a double CBCT approach, based on radiographic volume overlapping. Thirteen consecutive future totally edentulous patients (77 implants), divided into two groups (group A: 3–4 teeth traced; group B: 5–6 teeth traced) requiring a full arch implant prosthetic rehabilitation were included in the reported case series. A dynamic CAI was used to plan and to place all implants following all the recommended digital steps. The software used provided a tool (Trace and Place) that made the merge between X-ray views of the residual teeth and their own positions possible. This method definitely registered that teeth positions comply with the required accuracy live check. After implants placement, a post-operative CBCT was taken in order to evaluate the deviations of the achieved implants at coronal, apical, and depth level as well as angular deviations. Statistically significant radiological mean difference between the two groups was found in the coronal position of implants (0.26 mm, p < 0.001), in the apical position of implants (0.29 mm, p < 0.001), in the depth of implants (0.16 mm, p = 0.022), and in the angular deviation (0.7, p = 0.004). The use of the TaP technology for the treatment of the patients with at least three stable teeth that need to be removed for a totally implant prosthetic treatment is a promising technique. The performed accuracy analysis demonstrated that this digital protocol can be used without a loss of accuracy of the achieved implants compared to planned ones.

ALESSIO FRANCHINAALESSIO FRANCHINA
ALESSIO FRANCHINA
LSLuigi V. Stefanelli
Luigi V. Stefanelli
Fabio MalteseFabio Maltese
Fabio Maltese
GMGeorge A. Mandelaris
George A. Mandelaris
AVAlessandro Vantaggiato
Alessandro Vantaggiato
Stefano Di CarloStefano Di Carlo
Stefano Di Carlo
Computer aided implantology is the safest way to perform dental implants. The research of high accuracy represents a daily effort. The validated method to assess the accuracy of placed dental implants is the superimposition of a pre-operative and a post-operative cone beam computed tomography (CBCT) with planned and placed implants. This procedure is accountable for a biologic cost for the patient. To investigate alternative procedure for accuracy assessment, fifteen resin casts were printed. For each model, six implants were digitally planned and then placed following three different approaches: (a) template guided free hand, (b) static computer aided implantology (SCAI), and (c) dynamic computer aided implantology (DCAI). The placement accuracy of each implant was performed via two methods: the CBCT comparison described above and a matching between implant positions recovered from the original surgical plan with those obtained with a post-operative intraoral scan (IOS). Statistically significant mean differences between guided groups (SCAI and DCAI) and the free hand group were found at all considered deviations, while no differences resulted between the SCAI and DCAI approaches. Moreover, no mean statistically significant differences were found between CBCT and IOS assessment, confirming the validity of this new method.