yanjun Hu

Dr. yanjun Hu

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
WGWanjia Gao
Wanjia Gao
WLWenYi Liu
WenYi Liu
YHyanjun Hu
yanjun Hu
JWJun Wang
Jun Wang
In the method of monitoring the liquid level based on ultrasonic impedance, the near-field effect can seriously affect the validity of the results. In this paper, we explore the factors affecting the length of the ultrasonic near field. Based on that, we propose the optimal length and the minimum length of the buffer block to avoid the near field. The evaluations show that when the parameters of the ultrasonic probe are 15 mm in diameter, 1 MHz in frequency, and ±15 V in emitted ultrasonic wave amplitude, the best results are obtained when the length of the buffer block is 22 mm. When the probe diameter is 10 mm, the buffer block length should be ≥5 mm to ensure the validity of the measured results. The evaluation precision is 1 mm. This research can effectively avoid the blind area of emitted waves when using ultrasonic to measure the liquid level. It provides an effective basis for the selection and design of ultrasonic probes.

12 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
WGWanjia Gao
Wanjia Gao
WLWenYi Liu
WenYi Liu
FLFei Li
Fei Li
YHyanjun Hu
yanjun Hu
Selecting and designing the optimum ultrasonic probe is vital for ultrasonic measurements and experiments. The amplitude of the emitted ultrasonic wave excitation signal as well as the diameter and the natural frequency of the probe seriously affect the validity of the probe results. In this paper, we analyze the significance of the key parameters of the ultrasonic probe theoretically. Further, an external fixed-point liquid level monitoring system was assembled according to the principle of ultrasonic reflection and transmission. On this experimental platform, we study the key parameters of the ultrasonic probe that affect the system evaluation through a simulation and experiment, and select the optimal sensor parameters for this experiment. The evaluations show that under the experimental conditions where the tested container is made of aluminum alloy and its wall thickness is 3 mm, the best results are obtained when the diameter of the ultrasonic sensor is 15 mm, the amplitude of the emitted excitation signal is ±15 V, and the frequency is 1 MHz. The results’ average deviation is less than ±0.22 V. The evaluations are consistent with the simulation results. This research can effectively monitor the liquid in the closed, ultra-thin-walled container, and can realize non-contact measurement. It provides an effective basis for the parameters selection and design of the ultrasonic probe in the ultrasonic-based experiments and tests.

11 May 2020 in IEEE Access
Verified
Journal Article
Open access
YHyanjun Hu
yanjun Hu
YHYulong Hou
Yulong Hou
Abdul GhaffarAbdul Ghaffar
Abdul Ghaffar
WLWenYi Liu
WenYi Liu
A refractive index (RI) sensor based on plastic optical fiber (POF) with narrow groove structures coated with a gold layer (POF-NGS (Au)) is proposed and demonstrated. The proposed sensor was characterized using intensity interrogation, where the change in transmission power is induced by light filed interaction and Surface Plasmon Resonance (SPR). Narrow groove structures with lengths of 5 mm were fabricated using an ultraviolet laser, and a gold layer was sputtered to the surface of the whole fiber. The effect of the machining pitch on the RI response was studied. In this paper, dB and μW were used to represent the change of transmission power. Experiments have shown that the POF-NGS (Au) RI sensor has liner response between 1.340 and 1.356. The curvature of the output is largest when the machining pitch is 400 μm with sensitivity 12.5 dB/RIU (126 μW/RIU). The repeatability and temperature sensitivity characteristics were also characterized. Furthermore, the proposed sensor offers improved stability and signal to noise ratio.

12 February 2020 in Sensors
Verified
Journal Article
Open access
PDF file
WLWenYi Liu
WenYi Liu
YHyanjun Hu
yanjun Hu
YHYulong Hou
Yulong Hou
The three polypyrrole (PPy) films with different mixture ratios, namely PPy1, PPy2, and PPy3, were synthesized by chemical oxidation with pyrrole and ferric chloride (FeCl3). The roughened plastic optical fiber (POF) taper assembled PPy films (POF-PPy1, POF-PPy2, and POF-PPy3) were facilely prepared and bent U shape structure for testing ethanol gas at room temperature. The morphologies of the PPy films and the roughened POF taper were studied using electron microscopy. The effect of the three PPy films on the gas response was investigated and the results showed that the POF-PPy2 exhibited a high sensitivity of 5.08 × 10−5 dB/ppm. The detection limit of the sensor was 140 ppm and its response and recovery times were 5 s and 8 s, respectively. The results also showed that as the bending radius decreased, the response and recovery times gradually shortened, while the output power increased. In addition, the proposed sensor has advantages of a low cost and simple structure.

28 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
FLFei Li
Fei Li
WLWenYi Liu
WenYi Liu
WGWanjia Gao
Wanjia Gao
YLYanfang Liu
Yanfang Liu
YHyanjun Hu
yanjun Hu
Topology architecture has a decisive influence on network reliability. In this paper, we design a novel redundancy topology and analyze the structural robustness, the number of redundant paths between two terminal nodes, and the reliability of the proposed topology by using natural connectivity and time-independent and time-dependent terminal pair reliability, k-terminal reliability, and all-terminal reliability comprehensively and quantitatively, and we compare these measures of the proposed topology with AFDX in three scenarios. The evaluations show that in the structural robustness analysis, when no nodes are removed, the natural connectivity of the proposed topology with 10 nodes, 16 nodes, and 20 nodes is 77.8%, 26.95%, and 81.39% higher than that of AFDX, respectively. In the time-independent reliability analysis, when the link reliability is 0.9, terminal pair reliability of the proposed topology with 10 nodes, 16 nodes, and 20 nodes is 5.78%, 17.75%, and 34.65% higher than that of AFDX, respectively; k-terminal reliability is 10.04%, 31.97%, and 53.74% higher than that of AFDX, respectively; and all-terminal reliability is 29.36%, 74.37%, and 107.91% higher than that of AFDX, respectively. In the time-dependent reliability analysis, when the operating time is 8000 h, the terminal pair reliability of the proposed topology with 10 nodes, 16 nodes, and 20 nodes is 3.53%, 10.87%, and 21.08% higher than that of AFDX, respectively; the k-terminal reliability is 6.20%, 19.65%, and 32.58% higher than that of AFDX, respectively; and the all-terminal reliability is 18.25%, 45.04%, and 63.86% higher than that of AFDX, respectively. The proposed topology increases the redundant paths of data transmission. It ensures reliable data transmission and has high robustness and reliability. It provides a new idea for improving the reliability of industrial buses.

1 January 2018 in Journal of Sensors
Verified
Journal Article
Open access
YZYanjun Zhang
Yanjun Zhang
YZYingzi Zhang
Yingzi Zhang
YHYulong Hou
Yulong Hou
LZLliang Zhang
Lliang Zhang
YHyanjun Hu
yanjun Hu
WLWenYi Liu
WenYi Liu
An optical fiber liquid level sensor based on two twisted polymer optical fibers twining around a racetrack column is demonstrated in this study. The side-coupling power of the passive fiber is modulated by the refractive index (RI) of the environment medium and decreases while the liquid level increases. The variation patterns of the side-coupling power in the bent section and the straight section form a step attenuation, which can improve the measurement range with a superior sensitivity and distinguish liquids with different RIs. Furthermore, the cost-effective sensor also shows good reversibility and low temperature-dependent properties.