This article presents a strategy for enhancing the performance of the synchronized switch damping on inductor technique used for the semiactive control of structural vibrations. This enhancement is achieved by adding a negative capacitance to the resonant circuit that dissipates the energy converted by a piezoelectric transducer embedded in the structure. A unidimensional spring-mass system shunted synchronously to a resonant circuit is studied analytically, and the main parameters governing the performances of the system are highlighted. Experimental results obtained with a synthetic negative capacitance demonstrate the enhancement of the performance of synchronized switch damping on inductor and confirm the parametric dependencies identified analytically.
We discuss the concept of lightweight segmented bimorph mirrors for adaptive optics. The segment consists of a monocrystal silicon substrate actuated by an array of in-plane piezoceramic (PZT) actuators with honeycomb electrodes. We focus on technological aspects of the segment design that are critical for space applications and describe a single segment demonstrator. The morphing capability of the segment is evaluated experimentally. We also discuss the local deformations (dimples) associated with the shape of the electrodes acting on the PZT array.
In this paper, the design, simulations, and experimental results related to new analog circuits for voltage controlled synthetic inductors (VCSI) are presented. The new circuits based on a generalized impedance converter (GIC) are proposed for adaptive resonant piezoelectric shunt damping. The VCSIs are implemented using (1) an analog multiplier and (2) an operational transconductance amplifier (OTA) as voltage-controlled resistor. The simulation and experimental results for the new proposed VCSIs are presented and a comparative analysis follows. The proposed VCSIs work in a stable manner in parallel with negative impedance converters (NIC) to enhance structural damping in resonant piezoelectric resistive-inductive shunt applications. The behavior of the synthetic inductor is identical to a real inductor only in a specific frequency range and this situation can explain the reported spreading performance in the literature for resonant piezoelectric shunt damping. The simulation results are validated by a group of experimental investigations that confirm the improved stability and linearity of the new circuits proposed as VCSIs. Experimental results show that the VCSI based on an analog multiplier have an enhanced linearity in comparison with the OTA version in a limited voltage control range.
The impedance quartz crystal microbalance (QCMI) is a versatile and simple method for making accurate measurements of the QCM sensor electrical parameters. The QCM sensor provides access to the physical parameters of the sample beyond the mass per unit area by measuring the dissipation factor, or another equivalent, ensuring a detailed analysis of the surface. By establishing a cooperative relationship between custom software and modular configurable hardware we obtain a user-defined measurement system that is called a virtual instrument. This paper aims primarily to improve and adapt existing concepts to new electronics technologies to obtain a fast and accurate virtual impedance analyzer (VIA). The second is the implementation of a VIA by software to cover a wide range of measurements for the impedance of the QCM sensor, followed by the calculation of the value of lumped electrical elements in real time. A method for software compensation of the parallel and stray capacitance is also described. The development of a compact VIA with a decent measurement rate (192 frequency points per second) aims, in the next development steps, to create an accurate impedance analyzer for QCM sensors. The experimental results show the good working capacity of QCMI based on VIA.
Technological evolution has allowed impedance analysis to become a versatile and efficient method for the precise measurement of the equivalent electrical parameters of the quartz crystal microbalance (QCM). By measuring the dissipation factor, or another equivalent electrical parameter, the QCM sensor provides access to the sample mass per unit area and its physical parameters, thus ensuring a detailed analysis. This paper aims to demonstrate the benefits of advanced impedance spectroscopy concerning the Butterworth–van Dyke (BVD) model for QCM sensors immersed with an electrode in a liquid medium. The support instrument in this study is a fast and accurate software-defined virtual impedance analyzer (VIA) with real-time computing capabilities of the QCM sensor’s electric model. Advanced software methods of self-calibration, real-time compensation, innovative post-compensation, and simultaneous calculation by several methods are the experimental resources of the results presented in this paper. The experimental results validate the theoretical concepts and demonstrate both the capabilities of VIA as an instrument and the significant improvements brought by the advanced software methods of impedance spectroscopy analysis related to the BVD model.
28 February 1994 in Materials Chemistry and Physics