Amit L Sharma

Dr. Amit L Sharma


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2020 in ACS Omega
Verified
Journal Article
Closed access
NGNaini Garg
Naini Garg
MKMukesh Kumar
Mukesh Kumar
NKNeelam Kumari
Neelam Kumari
ADAkash Deep
Akash Deep
ASAmit L Sharma
Amit L Sharma

29 September 2020 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
AGArushi Gupta
Arushi Gupta
MGMayank Garg
Mayank Garg
SSSuman Singh
Suman Singh
ADAkash Deep
Akash Deep
ASAmit L Sharma
Amit L Sharma

13 May 2024 in Materials Chemistry and Physics
Verified
Journal Article
Closed access
SHShavita
Shavita
KTKamal Kishor Thakur
Kamal Kishor Thakur
ASAmit L Sharma
Amit L Sharma
SSSuman Singh
Suman Singh

1 March 2020 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MGMayank Garg
Mayank Garg
MCMary Chatterjee
Mary Chatterjee
ASAmit L Sharma
Amit L Sharma
SSSuman Singh
Suman Singh

5 August 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
MGMAYANK GARG
MAYANK GARG
MCMartin Gedsted Christensen
Martin Gedsted Christensen
AIAlexander Iles
Alexander Iles
ASAmit L Sharma
Amit L Sharma
SSSuman Singh
Suman Singh
Nicole PammeNicole Pamme
Nicole Pamme
Ferritin is a clinically important biomarker which reflects the state of iron in the body and is directly involved with anemia. Current methods available for ferritin estimation are generally not portable or they do not provide a fast response. To combat these issues, an attempt was made for lab-on-a-chip-based electrochemical detection of ferritin, developed with an integrated electrochemically active screen-printed electrode (SPE), combining nanotechnology, microfluidics, and electrochemistry. The SPE surface was modified with amine-functionalized graphene oxide to facilitate the binding of ferritin antibodies on the electrode surface. The functionalized SPE was embedded in the microfluidic flow cell with a simple magnetic clamping mechanism to allow continuous electrochemical detection of ferritin. Ferritin detection was accomplished via cyclic voltammetry with a dynamic linear range from 7.81 to 500 ng·mL−1 and an LOD of 0.413 ng·mL−1. The sensor performance was verified with spiked human serum samples. Furthermore, the sensor was validated by comparing its response with the response of the conventional ELISA method. The current method of microfluidic flow cell-based electrochemical ferritin detection demonstrated promising sensitivity and selectivity. This confirmed the plausibility of using the reported technique in point-of-care testing applications at a much faster rate than conventional techniques.

1 January 2021 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MGMayank Garg
Mayank Garg
ASAmit L Sharma
Amit L Sharma
SSSuman Singh
Suman Singh