Derek G. Shendell

Dr. Derek G. Shendell

School of Public Health, Rutgers University, Piscataway, NJ 08854, USA
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2004 in Indoor Air
Verified
Journal Article
Closed access
Derek G. ShendellDerek G. Shendell
Derek G. Shendell
RPR. Prill
R. Prill
WFW. J. Fisk
W. J. Fisk
MAM. G. Apte
M. G. Apte
DBD. Blake
D. Blake
DFD. Faulkner
D. Faulkner
Student attendance in American public schools is a critical factor in securing limited operational funding. Student and teacher attendance influence academic performance. Limited data exist on indoor air and environmental quality (IEQ) in schools, and how IEQ affects attendance, health, or performance. This study explored the association of student absence with measures of indoor minus outdoor carbon dioxide concentration (dCO(2)). Absence and dCO(2) data were collected from 409 traditional and 25 portable classrooms from 22 schools located in six school districts in the states of Washington and Idaho. Study classrooms had individual heating, ventilation, and air conditioning (HVAC) systems, except two classrooms without mechanical ventilation. Classroom attributes, student attendance and school-level ethnicity, gender, and socioeconomic status (SES) were included in multivariate modeling. Forty-five percent of classrooms studied had short-term indoor CO(2) concentrations above 1000 p.p.m. A 1000 p.p.m. increase in dCO(2) was associated (P < 0.05) with a 0.5-0.9% decrease in annual average daily attendance (ADA), corresponding to a relative 10-20% increase in student absence. Annual ADA was 2% higher (P < 0.0001) in traditional than in portable classrooms. This study provides motivation for larger school studies to investigate associations of student attendance, and occupant health and student performance, with longer term indoor minus outdoor CO(2) concentrations and more accurately measured ventilation rates. If our findings are confirmed, improving classroom ventilation should be considered a practical means of reducing student absence. Adequate or enhanced ventilation may be achieved, for example, with educational training programs for teachers and facilities staff on ventilation system operation and maintenance. Also, technological interventions such as improved automated control systems could provide continuous ventilation during occupied times, regardless of occupant thermal comfort demands.

12 May 2004 in Journal of Exposure Science & Environmental Epidemiology
Verified
Journal Article
Closed access
PDF file
QMQing Yu Meng
Qing Yu Meng
BTBarbara J Turpin
Barbara J Turpin
LKLeo Korn
Leo Korn
CWClifford P Weisel
Clifford P Weisel
MMMaria Morandi
Maria Morandi
SMSilvia Maberti
Silvia Maberti

3 May 2002 in Environmental Science & Technology
Verified
Journal Article
Closed access
YNYelena Y. Naumova
Yelena Y. Naumova
SESteven J. Eisenreich
Steven J. Eisenreich
BTBarbara J. Turpin
Barbara J. Turpin
CWClifford P. Weisel
Clifford P. Weisel
MMMaria T. Morandi
Maria T. Morandi
SWSteven J. Wall
Steven J. Wall

1 February 2010 in Indoor Air
Verified
Journal Article
Closed access
PDF file
NYNaomichi Yamamoto
Naomichi Yamamoto
Derek G. ShendellDerek G. Shendell
Derek G. Shendell
AWA. M. Winer
A. M. Winer
JZJunfeng Zhang
Junfeng Zhang
We report approximately 500 indoor-outdoor air exchange rate (AER) calculations based on measurements conducted in residences in three US metropolitan areas in 1999-2001: Elizabeth, New Jersey; Houston, Texas; and Los Angeles County, California. Overall, a median AER across these urban areas and seasons was 0.71 air changes per hour (ACH, or per hour; n = 509) while median AERs measured in California (n = 182), New Jersey (n = 163), and Texas (n = 164) were 0.87, 0.88, and 0.47 ACH, respectively. In Texas, the measured AERs were lower in the summer cooling season (median = 0.37 ACH) than in the winter heating season (median = 0.63 ACH), likely because of the reported use of room air conditioners as Houston is typically hot and humid during the summer. The measured AERs in California were higher in summer (median = 1.13 ACH) than in winter (median = 0.61 ACH). Because the summer cooling season in Los Angeles County is less humid than in New Jersey or Texas, natural ventilation through open windows and screened doors likely increased measured AER in California study homes. In New Jersey, AER were similar across heating and cooling seasons, although the median AER was relatively lower during the spring. Adequate ventilation or air exchange rate (AER) for an indoor environment is important for human health and comfort, and relevant to building design and energy conservation and efficiency considerations. However, residential AER data, especially measured by more accurate non-toxic tracer gas methodologies, are at present quite limited worldwide, and are insufficient to represent the variations across regions and seasons within and between homes, including apartments and condominiums in more densely populated urban areas. The present paper presents quantitative and qualitative data to characterize residential AERs in three US urban areas with different climate attributes.

27 November 2018 in Journal of Exposure Science & Environmental Epidemiology
Verified
Journal Article
Closed access
PDF file
JGJudith Graber
Judith Graber
CACora Alexander
Cora Alexander
RLRobert J. Laumbach
Robert J. Laumbach
KBKathleen Black
Kathleen Black
PSPamela Ohman Strickland
Pamela Ohman Strickland
CWClifford P. Weisel
Clifford P. Weisel

1 February 2003 in Atmospheric Environment
Verified
Journal Article
Closed access
YNYelena Y. Naumova
Yelena Y. Naumova
JOJohn H. Offenberg
John H. Offenberg
SESteven J. Eisenreich
Steven J. Eisenreich
QMQingyu Meng
Qingyu Meng
APAndrea Polidori
Andrea Polidori
CFCorice Farrar
Corice Farrar