Liping Wei

Dr. Liping Wei

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2017 in Sensors
Verified
Journal Article
Open access
PDF file
LWLiping Wei
Liping Wei
CYChris Yan
Chris Yan
DHDerek Ho
Derek Ho
Fluorescence spectroscopy has become a prominent research tool with wide applications in medical diagnostics and bio-imaging. However, the realization of combined high-performance, portable, and low-cost spectroscopic sensors still remains a challenge, which has limited the technique to the laboratories. A fluorescence lifetime measurement seeks to obtain the characteristic lifetime from the fluorescence decay profile. Time-correlated single photon counting (TCSPC) and time-gated techniques are two key variations of time-resolved measurements. However, commercial time-resolved analysis systems typically contain complex optics and discrete electronic components, which lead to bulkiness and a high cost. These two limitations can be significantly mitigated using contact sensing and complementary metal-oxide-semiconductor (CMOS) implementation. Contact sensing simplifies the optics, whereas CMOS technology enables on-chip, arrayed detection and signal processing, significantly reducing size and power consumption. This paper examines recent advances in contact sensing and CMOS time-resolved circuits for the realization of fully integrated fluorescence lifetime measurement microsystems. The high level of performance from recently reported prototypes suggests that the CMOS-based contact sensing microsystems are emerging as sound technologies for application-specific, low-cost, and portable time-resolved diagnostic devices.

10 September 2014 in Sensors
Verified
Journal Article
Open access
PDF file
LWLiping Wei
Liping Wei
SDSamer Doughan
Samer Doughan
YHYi Han
Yi Han
MDMatthew V. DaCosta
Matthew V. DaCosta
UKUlrich Krull
Ulrich Krull
DHDerek Ho
Derek Ho
Organic fluorophores and quantum dots are ubiquitous as contrast agents for bio-imaging and as labels in bioassays to enable the detection of biological targets and processes. Upconversion nanoparticles (UCNPs) offer a different set of opportunities as labels in bioassays and for bioimaging. UCNPs are excited at near-infrared (NIR) wavelengths where biological molecules are optically transparent, and their luminesce in the visible and ultraviolet (UV) wavelength range is suitable for detection using complementary metal-oxide-semiconductor (CMOS) technology. These nanoparticles provide multiple sharp emission bands, long lifetimes, tunable emission, high photostability, and low cytotoxicity, which render them particularly useful for bio-imaging applications and multiplexed bioassays. This paper surveys several key concepts surrounding upconversion nanoparticles and the systems that detect and process the corresponding luminescence signals. The principle of photon upconversion, tuning of emission wavelengths, UCNP bioassays, and UCNP time-resolved techniques are described. Electronic readout systems for signal detection and processing suitable for UCNP luminescence using CMOS technology are discussed. This includes recent progress in miniaturized detectors, integrated spectral sensing, and high-precision time-domain circuits. Emphasis is placed on the physical attributes of UCNPs that map strongly to the technical features that CMOS devices excel in delivering, exploring the interoperability between the two technologies.

31 January 2019 in IEEE Access
Verified
Journal Article
Open access
YTYi Tian
Yi Tian
CYChris Yan
Chris Yan
LWLiping Wei
Liping Wei
DHDerek Ho
Derek Ho
Photon-counting analysis plays a key role in many areas such as biology, chemistry, and medicine. In this paper, we present an integrated time-correlated single photon counting (TCSPC) lifetime analytical system with a complete signal path – from fluorophore excitation, emission detection, to lifetime extraction. The time-to-digital (TDC) module of the proposed TCSPC system achieves a root mean square (RMS) differential non-linearity (DNL) of 4% of the least significant bit (LSB) and a full width at half maximum (FWHM) temporal resolution from 121 ps to 145 ps within the 500 ns full-scale range (FSR). To evaluate the lifetime extraction and detection limit of the proposed TCSPC system, a wide variety of samples such as Fluorescein in water, Coumarin 6 in Dimethyl sulfoxide (DMSO), and Rhodamine 6G in water, each prepared in 14 concentrations from 0.5 nM (nanomolar, 10-9 mol/L) to 25 μM (micromolar, 10-6 mol/L), are tested. With optimized hardware and firmware design, the proposed TCSPC system can accurately extract the fluorescence lifetime of Fluorescein, Coumarin 6 and Rhodamine 6G down to the concentration of 1 nM, 1 nM, and 2.5 nM, respectively, significantly outperforming similar fluorescence lifetime analysis systems.

26 June 2019 in Sensors
Verified
Journal Article
Open access
PDF file
YTYi Tian
Yi Tian
LWLiping Wei
Liping Wei
DHDerek Ho
Derek Ho
Photon-counting analysis of nucleic acids plays a key role in many diagnostics applications for its accurate and non-invasive nature. However, conventional photon-counting instrumentations are bulky and expensive due to the use of conventional optics and a lack of optimization of electronics. In this paper, we present a portable, low-cost time-correlated single photon-counting (TCSPC) analysis system for DNA detection. Both optical and electronic subsystems are carefully designed to provide effective emission filtering and size reduction, delivering good DNA detection and fluorescence lifetime extraction performance. DNA detection has been verified by fluorescence lifetime measurements of a V-carbazole conjugated fluorophore lifetime bioassay. The time-to-digital module of the proposed TCSPC system achieves a full width at half maximum (FWHM) timing resolution from 121 to 145 ps and a differential non-linearity (DNL) between −8.5% and +9.7% of the least significant bit (LSB) within the 500 ns full-scale range (FSR). With a detection limit of 6.25 nM and a dynamic range of 6.8 ns, the proposed TCSPC system demonstrates the enabling technology for rapid, point-of-care DNA diagnostics.

12 August 2019 in IEEE Access
Verified
Journal Article
Open access
LWLiping Wei
Liping Wei
HLHoi Man Leung
Hoi Man Leung
YTYi Tian
Yi Tian
PLPik Kwan Lo
Pik Kwan Lo
DHDerek Ho
Derek Ho
Time-resolved fluorescence is a widely adopted technique for DNA detection due to its high sensitivity and selectivity. However, due to stringent requirements on optics and electronics, instrumentation with time-resolved capability is bulky and expensive, prohibiting their use in portable and point-of-care applications. In this work, a fully-integrated DNA biosensor based on liquid-core waveguide (LCW) optics for fluorescence lifetime analysis is presented. The DNA biosensor encompasses all-custom bioassay, optics and electronics into a microsystem, delivering a near sample-to-answer level of integration. Lifetime, rather than intensity, is exploited as the analytical signal from the V-carbazole probe for the first time. Excitation propagation within the LCW is investigated both analytically and in simulations to achieve high excitation rejection and low temporal dispersion, enabling the proposed LCW-based system with much smaller instrumentation size to deliver comparable lifetime measurement accuracy to traditional systems. Detection of DNA down to 15 base pairs at a low detection limit of 1.38 nM demonstrates the high applicability of the proposed biosensor for compact, application-specific, and low-cost diagnostics devices.