Agnieszka Matylda Schlichtinger

Dr. Agnieszka Matylda Schlichtinger

Faculty of Physics and Astronomy, Institute of Theoretical Physics, University of Wroclaw
+3
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 November 2023 in BioSystems
Verified
Journal Article
Closed access
Amirreza Khalili GolmankhanehAmirreza Khalili Golmankhaneh
Amirreza Khalili Golmankhaneh
STSümeyye Tunç
Sümeyye Tunç
ASAgnieszka Matylda Schlichtinger
Agnieszka Matylda Schlichtinger
Dachel Martínez-AsanzaDachel Martínez-Asanza
Dachel Martínez-Asanza
1

19 January 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
LPLilla Pawlik-Sobecka
Lilla Pawlik-Sobecka
KSKatarzyna Sołkiewicz
Katarzyna Sołkiewicz
IKIzabela Monika Kokot
Izabela Monika Kokot
AKAleksandra Kiraga
Aleksandra Kiraga
SPSylwia Płaczkowska
Sylwia Płaczkowska
Ewa Maria KratzEwa Maria Kratz
Ewa Maria Kratz
The present work aims at accessing the stability of biological material stored for diagnostic and scientific purposes. The influence of the temperature, storage time, and cyclic thawing on concentration stability of selected oxidative stress parameters in human serum was investigated. The study group consisted of 20 serum samples collected from healthy volunteers aged 18–52. The parameters whose reference ranges were not determined and to which validated determination methods did not correspond were examined by manual methods (FRAP and AOPP). Automatic methods were used to determine routine laboratory tests (albumin, total protein, bilirubin, uric acid) using the Konelab 20i® analyzer. The samples were stored at various temperatures (room temperature, 4 °C, −20 °C, −80 °C) for max 6 months and were subjected to cyclic thawing at 1 month intervals. In order to check whether any differences between the concentrations of the studied parameters existed when the samples were stored in various conditions, the paired Student t-test or Wilcoxon test and comparison to desirable bias were applied. Based on the obtained results, it was found that the temperature and time of serum sample storage significantly affected the stability of the analyzed parameters and determined different shelf lives of serum samples for oxidative stress examination. Therefore, continuing the investigation concerning the impact of storage conditions on various serum parameters seems justified due to the discrepancy between the individual results obtained by different researchers and the inconsistencies between the results of scientific research and the applicable recommendations.

4 June 2026 in Nutrients
Verified
Journal Article
Open access
PDF file
ASAnna Skrzek
Anna Skrzek
MSMałgorzata Renata Słowińska-Lisowska
Małgorzata Renata Słowińska-Lisowska
ADAgnieszka Dębiec-Bąk
Agnieszka Dębiec-Bąk
ASAgnieszka Matylda Schlichtinger
Agnieszka Matylda Schlichtinger
Background/Objectives: Body water, including its distribution between the intracellular (ICW) and extracellular (ECW) compartments, plays an important role in skeletal muscle physiology. The aim of this study was to assess whether body water distribution indices, namely ECW/ICW and ECW/TBW, differ according to age and sex, and whether they are associated with skeletal muscle index (SMI) after adjustment for BMI, age, and sex. Methods: The study included 188 healthy individuals: 71 older women (71.6 ± 6.4 years), 37 older men (72.7 ± 4.7 years), 40 female students (22.5 ± 0.9 years), and 40 male students (22.8 ± 1.8 years). Body composition was assessed using a Tanita MC-780 bioimpedance analyser. The ECW/ICW and ECW/TBW ratios were calculated. Nonparametric analyses, Kendall’s rank correlations, and linear regression models adjusted for BMI, age, and sex were used. Results: Older adults had significantly higher ECW/ICW and ECW/TBW values than younger participants, and women had higher values than men within the same age groups. Both indices correlated positively with age and BMI, and negatively with SMI. In multivariate models, ECW/TBW remained negatively associated with SMI after adjustment. BMI and male sex correlated positively with SMI, whereas age was not a significant predictor. Conclusions: Body water distribution indices (ECW/ICW, ECW/TBW) reflect age- and sex-related differences in water distribution and correlate with SMI independently of BMI, age, and sex. They may serve as complementary markers of skeletal muscle ageing.

14 December 2023 in arXiv
Verified
Preprint
Open access
PDF file
ASAgnieszka Matylda Schlichtinger
Agnieszka Matylda Schlichtinger
AJA. Jadczyk
A. Jadczyk
It is shown that in presence of certain external fields a well defined self-adjoint time operator exists, satisfying the standard canonical commutation relations with the Hamiltonian. Examples include uniform electric and gravitational fields with nonrelativistic and relativistic Hamiltonians. The physical intepretation of these operators is proposed in terms of time of arrival in the momentum space.

16 July 2026
Verified
Preprint
Open access
PDF file
ASAgnieszka Matylda Schlichtinger
Agnieszka Matylda Schlichtinger
The revised manuscript contains several presentational improvements, but the principal mathematical and physical objections remain unresolved. In particular, the manuscript does not adequately distinguish the auxiliary space from the constrained phys...