Visible light positioning has the potential to be a cost-effective technology for accurate indoor positioning. However, existing approaches often require large amounts of incoming data, usually in the form of high resolution images or dense lighting distributions. Additionally, a line of sight between transmitter and receiver is generally required at all times. In this work, we present a positioning approach that combines measurements from a camera, encoders and a gyroscope. We compare multiple algorithms for fusing these data, namely an extended Kalman filter, a particle filter and a hybrid approach. The end result is a system that provides location estimates even with sparse lighting distributions and temporary outages, yet achieves an average accuracy of 2 to 4 cm. Even in the 95th percentile of the cumulative error distribution, accuracy can be as low as 2 cm and is often lower than 10 cm. Moreover, due to the use of a low-resolution camera (640x480 pixels) and efficient fusion algorithms, the latency is relatively low on a standard laptop (between 5.6 and 21 milliseconds). Even on a low-cost embedded board, latency generally does not exceed 100 milliseconds. We validate our approach experimentally and show that it is robust under a wide range of illumination conditions.
Localization based on visible light is a novel technique for indoor positioning that provides a number of advantages over traditional radio frequency based approaches. An important step in the deployment of visible light positioning systems is the calibration procedure, during which environmental parameters such as the positions of light sources are determined. This work presents a proof-of-concept approach to obtain these parameters in an efficient manner by using a mobile robot. This robot builds a map of the environment, and adds the location and identifier of optical transmitters to this map. With this approach, light source modulation frequencies can be estimated with sufficient accuracy to uniquely identify each source. Additionally, the inter-LED distance has an average accuracy of less than 10 cm compared to the real distance.
Most indoor positioning systems require calibration before use. Fingerprinting requires the construction of a signal strength map, while ranging systems need the coordinates of the beacons. Calibration approaches exist for positioning systems that use Wi-Fi, radio frequency identification or ultrawideband. However, few examples are available for the calibration of visible light positioning systems. Most works focused on obtaining the channel model parameters or performed a calibration based on known receiver locations. In this paper, we describe an improved procedure that uses a mobile robot for data collection and is able to obtain a map of the environment with the beacon locations and their identities. Compared to previous work, the error is almost halved. Additionally, this approach does not require prior knowledge of the number of light sources or the receiver location. We demonstrate that the system performs well under a wide range of lighting conditions and investigate the influence of parameters such as the robot trajectory, camera resolution and field of view. Finally, we also close the loop between calibration and positioning and show that our approach has similar or better accuracy than manual calibration.
Indoor positioning with visible light has become increasingly important in recent years. Usually, light sources are modulated at high speeds in order to wirelessly transmit data from the fixtures to a receiver. The accuracy of such systems can range from a few decimeters to a few centimeters. However, additional modulation hardware is required for every light source, thereby increasing cost and system complexity. This paper investigates the use of unmodulated light for indoor positioning. Contrary to previous work, a Kalman filter is used instead of a particle filter to decrease the computational load. As a result, the update rate of position estimation can be higher. Additionally, more resources could be made available for other tasks (e.g., path planning for autonomous robots). We evaluated the performance of our proposed approach through simulations and experiments. The accuracy depends on a number of parameters, but is generally lower than 0.5 m. Moreover, temporary occlusion of the receiver can be compensated in most cases.
With the rise of solid state lighting, wireless positioning based on visible light is becoming more appealing. However, current visible light positioning systems require additional hardware at the transmitter end in order to modulate the light intensity. A receiver demultiplexes the combined signal from multiple sources into its components, which are then used by the positioning algorithm. This paper investigates the possibility of using unmodulated visible light for mobile robot positioning. Less hardware is required, consequently cost and complexity are much lower. Position estimation is achieved by modeling the received signal strength inside a room, which is used as input for an Iterated Extended Kalman filter. We show that the proposed approach can achieve decimeter level accuracy in a simulation environment. Even with imperfect calibration, the total positioning error usually remains below 0.5 m. Positioning errors due to blocking of the receiver can be mitigated by employing an innovation magnitude bounds test. We also show that by employing multiple receivers, accuracy and robustness can be further improved.