To what extent electrocorticography (ECoG) and electroencephalography (scalp EEG) differ in their capability to locate sources of deep brain activity is far from evident. Compared to EEG, the spatial resolution and signal-to-noise ratio of ECoG is superior but its spatial coverage is more restricted, as is arguably the volume of tissue activity effectively measured from. Moreover, scalp EEG studies are providing evidence of locating activity from deep sources such as the hippocampus using high-density setups during quiet wakefulness. To address this question, we recorded a multimodal dataset from 4 patients with refractory epilepsy during quiet wakefulness. This data comprises simultaneous scalp, subdural and depth EEG electrode recordings. The latter was located in the hippocampus or insula and provided us with our "ground truth" for source localization of deep activity. We applied independent component analysis (ICA) for the purpose of separating the independent sources in theta, alpha and beta frequency band activity. In all patients subdural- and scalp EEG components were observed which had a significant zero-lag correlation with one or more contacts of the depth electrodes. Subsequent dipole modeling of the correlating components revealed dipole locations that were significantly closer to the depth electrodes compared to the dipole location of non-correlating components. These findings support the idea that components found in both recording modalities originate from neural activity in close proximity to the depth electrodes. Sources localized with subdural electrodes were ~70% closer to the depth electrode than sources localized with EEG with an absolute improvement of around ~2cm. In our opinion, this is not a considerable improvement in source localization accuracy given that, for clinical purposes, ECoG electrodes were implanted in close proximity to the depth electrodes. Furthermore, the ECoG grid attenuates the scalp EEG, due to the electrically isolating silastic sheets in which the ECoG electrodes are embedded. Our results on dipole modeling show that the deep source localization accuracy of scalp EEG is comparable to that of ECoG. SIGNIFICANCE STATEMENT: Deep and subcortical regions play an important role in brain function. However, as joint recordings at multiple spatial scales to study brain function in humans are still scarce, it is still unresolved to what extent ECoG and EEG differ in their capability to locate sources of deep brain activity. To the best of our knowledge, this is the first study presenting a dataset of simultaneously recorded EEG, ECoG and depth electrodes in the hippocampus or insula, with a focus on non-epileptiform activity (quiet wakefulness). Furthermore, we are the first study to provide experimental findings on the comparison of source localization of deep cortical structures between invasive and non-invasive brain activity measured from the cortical surface.
Background: Brain-computer interfaces decode intentions directly from the human brain with the aim to restore lost functionality, control external devices or augment daily experiences. To combine optimal performance with wide applicability, high-quality brain signals should be captured non-invasively. Magnetoencephalography (MEG) is a potent candidate but currently requires costly and confining recording hardware. The recently developed optically pumped magnetometers (OPMs) promise to overcome this limitation, but are currently untested in the context of neural interfacing. Results: In this work, we show that OPM-MEG allows robust single-trial analysis which we exploited in a real-time ‘mind-spelling’ application yielding an average accuracy of 97.7%. Conclusions: This shows that OPM-MEG can be used to exploit neuro-magnetic brain responses in a practical and flexible manner, and opens up new avenues for a wide range of new neural interface applications in the future.
Brain–computer interfacing has enjoyed growing attention, not only due to the stunning demonstrations with severely disabled patients, but also the advent of economically viable solutions in areas such as neuromarketing, mental state monitoring, and future human–machine interaction. An interesting case, at least for neuromarketers, is to monitor the customer’s mental state in response to watching a commercial. In this paper, as a novelty, we propose a method to predict from electroencephalography (EEG) recordings whether individuals decide to skip watching a video trailer. Based on multiscale sample entropy and signal power, indices were computed that gauge the viewer’s engagement and emotional affect. We then trained a support vector machine (SVM), a k-nearest neighbor (kNN), and a random forest (RF) classifier to predict whether the viewer declares interest in watching the video and whether he/she decides to skip it prematurely. Our model achieved an average single-subject classification accuracy of 75.803% for skipping and 73.3% for viewer interest for the SVM, 82.223% for skipping and 78.333% for viewer interest for the kNN, and 80.003% for skipping and 75.555% for interest for the RF. We conclude that EEG can provide indications of viewer interest and skipping behavior and provide directions for future research.
The risk of personal data exposure through unauthorized access has never been as imminent as today. To counter this, biometric authentication has been proposed: the use of distinctive physiological and behavioral characteristics as a form of identification and access control. One of the recent developments is electroencephalography (EEG)-based authentication. It builds on the subject-specific nature of brain responses which are difficult to recreate artificially. We propose an authentication system based on EEG signals recorded in response to a simple motor paradigm. Authentication is achieved with a novel two-stage decoder. In the first stage, EEG signal features are extracted using an inception- and a VGG-like deep learning neural network (NN) both of which we compare with principal component analysis (PCA). In the second stage, a support vector machine (SVM) is used for binary classification to authenticate the subject based on the extracted features. All decoders are trained on EEG motor-movement data recorded from 105 subjects. We achieved with the VGG-like NN-SVM decoder a false-acceptance rate (FAR) of 2.55% with an overall accuracy of 88.29%, a FAR of 3.33% with an accuracy of 87.47%, and a FAR of 2.89% with an accuracy of 90.68% for 8, 16, and 64 channels, respectively. With the Inception-like NN-SVM decoder we achieved a false-acceptance rate (FAR) of 4.08% with an overall accuracy of 87.29%, a FAR of 3.53% with an accuracy of 85.31%, and a FAR of 1.27% with an accuracy of 93.40% for 8, 16, and 64 channels, respectively. The PCA-SVM decoder achieved accuracies of 92.09%, 92.36%, and 95.64% with FARs of 2.19%, 2.17%, and 1.26% for 8, 16, and 64 channels, respectively.
The usability of EEG-based visual brain–computer interfaces (BCIs) based on event-related potentials (ERPs) benefits from reducing the calibration time before BCI operation. Linear decoding models, such as the spatiotemporal beamformer model, yield state-of-the-art accuracy. Although the training time of this model is generally low, it can require a substantial amount of training data to reach functional performance. Hence, BCI calibration sessions should be sufficiently long to provide enough training data. This work introduces two regularized estimators for the beamformer weights. The first estimator uses cross-validated L2-regularization. The second estimator exploits prior information about the structure of the EEG by assuming Kronecker–Toeplitz-structured covariance. The performances of these estimators are validated and compared with the original spatiotemporal beamformer and a Riemannian-geometry-based decoder using a BCI dataset with P300-paradigm recordings for 21 subjects. Our results show that the introduced estimators are well-conditioned in the presence of limited training data and improve ERP classification accuracy for unseen data. Additionally, we show that structured regularization results in lower training times and memory usage, and a more interpretable classification model.
With the advent of the digital age, concern about how to secure authorized access to sensitive data is increasing. Besides traditional authentication methods, there is an interest in biometric traits such as fingerprints, the iris, facial characteristics, and, recently, brainwaves, primarily based on electroencephalography (EEG). Current work on EEG-based authentication focuses on acute recordings in laboratory settings using high-end equipment, typically equipped with 64 channels and operating at a high sampling rate. In this work, we validated the feasibility of EEG-based authentication in a real-world, out-of-laboratory setting using a commercial dry-electrode EEG headset and chronic recordings on a population of 15 healthy people. We used an LSTM-based network with bootstrap aggregating (bagging) to decode our recordings in response to a multitask scheme consisting of performed and imagined motor tasks, and showed that it improved the performance of the standard LSTM approach. We achieved an authentication accuracy, false acceptance rate (FAR), and false rejection rate (FRR) of 92.6%, 2.5%, and 5.0% for the performed motor task; 92.5%, 2.6%, and 4.9% for the imagined motor task; and 93.0%, 1.9%, and 5.1% for the combined tasks, respectively. We recommend the proposed method for time- and data-limited scenarios.