Pavol Stodulka

Pavol Stodulka


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2019 in Polymers
Verified
Journal Article
Open access
PDF file
SRShah Rushita
Shah Rushita
PSPavol Stodulka
Pavol Stodulka
KSKateřina Skopalová
Kateřina Skopalová
PSPetr Saha
Petr Saha
The application of polymeric biomaterial scaffolds utilizing crosslinking strategy has become an effective approach in these days. In the present study, the development and characterization of collagen–chitosan hydrogel film has been reported on using dual crosslinking agent’s, i.e., tannic acid and genipin simultaneously. Incorporation of genipin imparts a greenish-blue color to the polymeric film. The effect of dual crosslinking and their successful interaction within the matrix was evaluated by infrared analysis spectroscopy. The porosity of the film was examined using scanning electron microscopy (SEM). Results of TGA determine the intermediate thermal degradation. Further, the crosslinking phenomenon has found primary impact on the strength of the films. Enzymatic degradation for the films was performed with lysozyme and lipase. The cell adhesion and proliferation was also accomplished using mouse embryonic cell lines wherein the cells cultured on the dual crosslinked film. The thriving utilization of such dual crosslinked polymeric film finds their applications in ophthalmology especially as an implant for temporary injured cornea and skin tissue regeneration.

1 May 2019 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
PSPavol Stodulka
Pavol Stodulka
RPRichard Packard
Richard Packard
DMDavid Mordaunt
David Mordaunt
To compare the efficacy and safety of anterior capsulotomy creation with a new selective laser device (CAPSULaser) with those of manual capsulotomies. GEMINI Eye Clinic, Zlin, Czech Republic. Prospective case series. Patients were placed in cohorts based on age and cataract grade and randomly allocated to have laser capsulotomy or manual continuous curvilinear capsulorhexis (CCC). The anterior capsule was stained with microfiltered trypan blue 0.4%. The anterior capsulotomy was created with the laser device focused on the anterior capsule through a custom patient interface lens. Intraoperative video analysis with the use of an intraocular ruler and postoperative examinations were used to assess safety and efficacy (accuracy of capsulotomy size, circularity, centration). No intraoperative complications occurred in the laser group or the manual group. All capsulotomies in the laser group were free-floating with no tags or tears. The mean capsulotomy diameter was 5.03 mm overall (range 4.8 to 5.2 mm, laser group; 4.4 to 5.8 mm, manual group). In the laser group, all the capsulotomies were within 0.1 mm ± 0.1 (SD) of the target. The circularity accuracy was greater than 99.0% ± 1.0%; the mean centration of the capsulotomy in relation to the intraocular lens (IOL) was 0.1 ± 0.1 mm. All parameters were statistically significant (P < .01). The IOL-capsulotomy overlap was 360 degrees in all laser cases. Selective laser capsulotomy using a new proprietary trypan blue formulation was safe and effective in cataract surgery. The sizing, circularity, and centration of the laser capsulotomy were more accurate than those of the manual CCC, resulting in consistent 360-degree IOL coverage.

1 January 2020 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
PSPavol Stodulka
Pavol Stodulka
MSMartin Me Sramka
Martin Me Sramka
JPJaroslav Polisensky
Jaroslav Polisensky
KLKarel Msc Liska
Karel Msc Liska
Purpose: To report the initial experience with a new presbyopic phakic intraocular lens (pIOL) in the correction of high myopia and presbyopia. Setting: Gemini Eye Clinic, Zlin, Czech Republic. Design: Prospective cohort study. Methods: Presbyopic eyes with moderate to high myopia were implanted with a presbyopic posterior chamber pIOL (IPCL). The visual acuities at near and distance, endothelial cell density, and ocular condition were examined 1 week, 3 months, 1 year and 2 years postoperatively. Results: The mean uncorrected distance visual acuity improved significantly from 1.25 logarithm of the minimum angle of resolution (logMAR) (1.15 to 1.35 95% confidence interval [CI]) to 0.11 logMAR (95% CI, 0.03 to 0.17) (P < .0001). No eye lost 1 or more lines of corrected distance visual acuity. The mean distance refraction improved significantly from −6.9 diopters (D) (range −8.6 to −5.3 D) preoperatively to −0.35 D (range −0.55 to −0.15 D, P < .0001) with less than −0.5 D residual refraction in 11 of 17 eyes. Fifteen of 17 eyes had improved uncorrected near visual acuity to J1 (Jaeger chart) at the 2-year follow-up. The near addition at the 2-year follow-up decreased from preoperatively +1.26 D (range 0.19 to 2.34 D) to +0.39 D (range 0.18 to 0.60 D). The mean endothelial cell density was reduced from 2552 cells/mm2 (range 2421 to 2682 cells/mm2) to 2299 cells/mm2 (range 2108 to 2490 cells/mm2) after 2 years. All patients were subjectively satisfied with the outcomes. Conclusions: The new pIOL provided good visual outcomes in near and far distances in an initial case series of patients.

1 August 2023 in Clinical Ophthalmology
Verified
Journal Article
Open access
PDF file
RARobert Edward T Ang
Robert Edward T Ang
PSPavol Stodulka
Pavol Stodulka
FPFrancisco Poyales
Francisco Poyales
Purpose: To assess refractive and visual outcomes of bilateral implantation of an isofocal optic-design intraocular lens (IOL) or a monofocal IOL following cataract surgery. Methods: A total of 127 patients were recruited into a prospective, single-masked, randomized trial. Sixty-five patients bilaterally implanted with the Isopure Isofocal IOL and 62 patients with the Micropure Monofocal IOL were followed for 4– 6 months. Refraction, monocular and binocular uncorrected-distance-visual acuity, corrected-distance-visual acuity (CDVA), uncorrected-intermediate-visual acuity and distance-corrected-intermediate-visual acuity (DCIVA, 66/80 cm), uncorrected-near-visual acuity, and distance-corrected-near-visual acuity (DCNVA, 40 cm) were evaluated. Binocular defocus curve, binocular contrast sensitivity (photopic, mesopic with/without glare), and glare and halo phenomena were also measured. Results: 99.23% of eyes were within ± 1.00D and 84.62% of eyes within ± 0.50D for the Isopure patients and 98.39% and 82.26% for the Micropure patients, respectively. The mean spherical-equivalent was − 0.06 ± 0.36D and 0.10 ± 0.32D for the Isopure and Micropure patients, respectively. 98.5% and 100% of patients implanted with the Isopure and Micropure IOLs showed a cumulative binocular CDVA value ≥ 20/20, respectively. 80% and 67.70% of patients implanted with the Isopure presented a binocular DCIVA ≥ 20/25 at 80 and 66 cm, respectively. These percentages were 46.8% and 40.3% with the Micropure IOL, respectively. For Isopure, 7.7%, 30.8%, and 58.5% of patients presented a DCNVA ≥ 20/25, ≥ 20/32 and ≥ 20/40, respectively. These values were lower for the Micropure: 1.6%, 19.4% and 46.8%, respectively. Defocus curves showed similar good visual acuity at distance for both lenses with better intermediate vision for the Isopure. Both groups presented good contrast sensitivity, and the size and intensity of halo and glare phenomena were similar between the two. No adverse-events were reported. Conclusion: Our trial shows that both IOLs provide excellent visual acuity and contrast sensitivity for far vision with similar photic phenomena, and the Isopure IOL improved unaided intermediate vision performance.

1 December 2013 in I-Perception
Verified
Journal Article
Open access
RŠRadovan Šikl
Radovan Šikl
MŠMichal Šimeček
Michal Šimeček
MPMichaela Porubanová-Norquist
Michaela Porubanová-Norquist
OBOndřej Bezdíček
Ondřej Bezdíček
JKJan Kremláček
Jan Kremláček
YOYuri Ostrovsky
Yuri Ostrovsky
Several studies have shown that visual recovery after blindness that occurs early in life is never complete. The current study investigated whether an extremely long period of blindness might also cause a permanent impairment of visual performance, even in a case of adult-onset blindness. We examined KP, a 71-year-old man who underwent a successful sight-restoring operation after 53 years of blindness. A set of psychophysical tests designed to assess KP's face perception, object recognition, and visual space perception abilities were conducted six months and eight months after the surgery. The results demonstrate that regardless of a lengthy period of normal vision and rich pre-accident perceptual experience, KP did not fully integrate this experience, and his visual performance remained greatly compromised. This was particularly evident when the tasks targeted finer levels of perceptual processing. In addition to the decreased robustness of his memory representations, which was hypothesized as the main factor determining visual impairment, other factors that may have affected KP's performance were considered, including compromised visual functions, problems with perceptual organization, deficits in the simultaneous processing of visual information, and reduced cognitive abilities.

1 January 2023 in Therapeutic Advances in Ophthalmology
Verified
Journal Article
Open access
PSPavol Stodulka
Pavol Stodulka
ZPZuzana Pracharova
Zuzana Pracharova
Background: Extended depth-of-focus (EDOF) intraocular lenses (IOLs) provide a continuous range of uncorrected vision at different distances. Objective: To assess visual acuity, refractive outcomes, and patient satisfaction after cataract surgery using the LuxSmart EDOF IOL (Bausch+Lomb). Design: A two-center, prospective observational clinical study. Methods: This study includes patients who have undergone bilateral phacoemulsification with bilateral implantation of the LuxSmart EDOF IOL, with the aim of achieving emmetropia. Visual acuity (VA) and subjective refraction were obtained in all patients preoperatively and at 1 week, 1 month, 3 months, and 6 months postoperatively. Subjective measures were obtained using the Catquest-9SF questionnaire and the Patient-Reported Spectacle Independence Questionnaire (PRSIQ). Contrast sensitivity and a glare assessment were undertaken postoperatively. Safety outcomes were additionally assessed. Results: Sixty eyes from thirty patients were recruited for this study. The mean spherical equivalent was 1.04 ± 1.67 D preoperatively and −0.30 ± 0.46 D at 6 months. Monocular uncorrected distance VA was 0.57 ± 0.32 (logMAR) preoperatively and 0.09 ± 0.12 (logMAR) at 6 months. Mean 6-month monocular uncorrected VA was 0.11 ± 0.13, 0.12 ± 0.15, and 0.31 ± 0.15 (logMAR) at 80, 66, and 40 cm, respectively. More than 90% of patients were either fairly or very satisfied with their vision. There was one case of suspected vitreomacular traction postoperatively. Conclusion: The LuxSmart EDOF IOL offers good refractive, VA, and safety outcomes. The single elongated focal point designed to enhance the DOF shows good results for VA and patient satisfaction.