Ceming Wang

Dr. Ceming Wang


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2013 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
YYYu Yan
Yu Yan
QSQian Sheng
Qian Sheng
CWCeming Wang
Ceming Wang
JXJianming Xue
Jianming Xue
HCHsueh-Chia Chang
Hsueh-Chia Chang

8 January 2021 in Nature Communications
Verified
Journal Article
Open access
PDF file
CWCeming Wang
Ceming Wang
SSSebastian Sensale
Sebastian Sensale
ZPZehao Pan
Zehao Pan
SSSatyajyoti Senapati
Satyajyoti Senapati
HCHsueh-Chia Chang
Hsueh-Chia Chang
Solid-state nanopores allow high-throughput single-molecule detection but identifying and even registering all translocating small molecules remain key challenges due to their high translocation speeds. We show here the same electric field that drives the molecules into the pore can be redirected to selectively pin and delay their transport. A thin high-permittivity dielectric coating on bullet-shaped polymer nanopores permits electric field leakage at the pore tip to produce a voltage-dependent surface field on the entry side that can reversibly edge-pin molecules. This mechanism renders molecular entry an activated process with sensitive exponential dependence on the bias voltage and molecular rigidity. This sensitivity allows us to selectively prolong the translocation time of short single-stranded DNA molecules by up to 5 orders of magnitude, to as long as minutes, allowing discrimination against their double-stranded duplexes with 97% confidence.

3 August 2015 in Analytical Chemistry
Verified
Journal Article
Closed access
CWCeming Wang
Ceming Wang
QFQibin Fu
Qibin Fu
XWXinwei Wang
Xinwei Wang
DKDelin Kong
Delin Kong
QSQian Sheng
Qian Sheng
JXJianming Xue
Jianming Xue

14 March 2012 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
CWCeming Wang
Ceming Wang
LWLin Wang
Lin Wang
XZXiaorui Zhu
Xiaorui Zhu
YWYugang Wang
Yugang Wang
JXJianming Xue
Jianming Xue
Track-etched polymer membranes are used to realize low-voltage electroosmotic (EO) pumps. The nanopores in polycarbonate (PC) and polyethylene terephthalate (PET) membranes were fabricated by the track-etching technique, the pore diameter was controlled in the range of 100 to 250 nm by adjusting the etching time. The results show that these EO pumps can provide high flow rates at low applied voltages (2–5 V). The maximum normalized flow rate is as high as 0.12 ml min−1 V−1 cm−2, which is comparable to the best values of previously demonstrated EO pumps. We attribute this high performance to the unique properties of the track-etched nanopores in the membranes.

1 May 2016 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
AEAna Egatz-Gomez
Ana Egatz-Gomez
CWCeming Wang
Ceming Wang
FKFlora Klacsmann
Flora Klacsmann
ZPZehao Pan
Zehao Pan
SMSteve Marczak
Steve Marczak
HCHsueh-Chia Chang
Hsueh-Chia Chang
Nucleic acid biomarkers have enormous potential in non-invasive diagnostics and disease management. In medical research and in the near future in the clinics, there is a great demand for accurate miRNA, mRNA, and ctDNA identification and profiling. They may lead to screening of early stage cancer that is not detectable by tissue biopsy or imaging. Moreover, because their cost is low and they are non-invasive, they can become a regular screening test during annual checkups or allow a dynamic treatment program that adjusts its drug and dosage frequently. We briefly review a few existing viral and endogenous RNA assays that have been approved by the Federal Drug Administration. These tests are based on the main nucleic acid detection technologies, namely, quantitative reverse transcription polymerase chain reaction (PCR), microarrays, and next-generation sequencing. Several of the challenges that these three technologies still face regarding the quantitative measurement of a panel of nucleic acids are outlined. Finally, we review a cluster of microfluidic technologies from our group with potential for point-of-care nucleic acid quantification without nucleic acid amplification, designed to overcome specific limitations of current technologies. We suggest that integration of these technologies in a modular design can offer a low-cost, robust, and yet sensitive/selective platform for a variety of precision medicine applications.

1 November 2017 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
DLDiya Li
Diya Li
CWCeming Wang
Ceming Wang
GSGongchen Sun
Gongchen Sun
SSSatyajyoti Senapati
Satyajyoti Senapati
HCHsueh-Chia Chang
Hsueh-Chia Chang