fan wu

Mr. fan wu


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

6 December 2019 in Energies
Verified
Journal Article
Open access
PDF file
FWfan wu
fan wu
JWJun Wang
Jun Wang
ZSZhang Sun
Zhang Sun
Tao WangTao Wang
Tao Wang
LCLei Chen
Lei Chen
XHXiaoyan Han
Xiaoyan Han
Due to the volatility of natural resources, the power fluctuations of photovoltaic (PV) generation have serious negative impacts on the power quality. This paper reports a novel approach to resolve this problem in a combined cascade hydro-PV-pumped storage (CH-PV-PS) generation system through appropriate power distribution on a small time scale. According to the characteristics of power generation systems and multi-constraints, how to obtain the optimal smoothing effects with the small cost is a key challenge. For this purpose, wavelet packet decomposition is modified by constructing cost function and ideal power trajectory sequences to obtain a new adaptive power distribution method for the CH-PV-PS generation system considering the boundary conditions of the system in this paper. At the same time, to meet the real-time control requirements of actual systems, an additive function is presented to improve the optimization speed of the adaptive power distribution method. In the meantime, a fuzzy controller is designed to optimize the inevitable delay time of the power scheduling system, and the starting threshold is set to avoid the frequently mode conversion of pumped storage. Finally, the performance of the method is evaluated based on the PV station data in Xiaojin County, Sichuan Province, China. Simulation results based on Matlab-simulink indicate that the proposed method can effectively suppress PV power fluctuations and ensure normal operation of the CH-PV-PS generation system within the multiple constraints.

17 February 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Gen QiuGen Qiu
Gen Qiu
FWfan wu
fan wu
KCKai Chen
Kai Chen
LWLi Wang
Li Wang
When an insulated-gate bipolar transistor (IGBT) open-circuit fault occurs, a three-phase pulse-width modulated (PWM) converter can usually keep working, which will lead to system instability and more serious secondary faults. The fault detection and diagnosis of the converter is extremely necessary to improve the reliability of the power supply system. In order to solve the problem of fault misdiagnosis caused by parameters disturbance, this paper proposes a robust accuracy weighted random forests online fault diagnosis model to accurately locate various IGBTs open-circuit faults. Firstly, the fault signal features are preprocessed by using the three-phase current signal and normalization method. Based on the test accuracy of the perturbed out-of-bag data and the multiple converters test data, a robust accuracy weighted random forests algorithm is proposed for extracting a mapping relationship between fault modes and current signal. In order to further improve the fault diagnosis performance, a parameter optimization model is built to optimize hyper-parameters of the proposed method. Finally, comparative simulation and online fault diagnosis experiments are carried out, and the results demonstrate the effectiveness and superiority of the method.

18 December 2019 in IEEE Access
Verified
Journal Article
Open access
ZSZhang Sun
Zhang Sun
FWfan wu
fan wu
WJWeidong Jin
Weidong Jin
JWJun Wang
Jun Wang
YWYunpu Wu
Yunpu Wu
ZWZhongjun Wei
Zhongjun Wei
Regulating the output current and reducing the harmonic distortion are key control problems in the airport navigation dimming power supply (DPS). In this study, a new method which could dynamically adjust P and I gains is presented for the DPS based on the radial basis function (RBF) neural networks combined with the gradient descent method. To implement the proposed method, the key factors which influence the performance of DPS are revealed by analyzing the dynamic response of the control system. The controller design process is presented in detail along with a system stability analysis. The correctness of theoretical derivation is examined through extensive digital computer simulation analyses in MATLAB while the comparative analysis is carried out under different operation conditions through experiments in a 30kW experimental prototype. The results indicate that the DPS adopting the method proposed in this paper could obtain better dynamic response and less harmonic content in various complex working conditions.