Oonagh M. Giggins

Dr. Oonagh M. Giggins

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2021 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
DMDavid Muggeridge
David Muggeridge
KHKirsty Hickson
Kirsty Hickson
ADAimie Victoria Davies
Aimie Victoria Davies
OGOonagh M. Giggins
Oonagh M. Giggins
Ian MegsonIan Megson
Ian Megson
DCDaniel Crabtree
Daniel Crabtree
Background: Accurate, continuous heart rate measurements are important for health assessment, physical activity, and sporting performance, and the integration of heart rate measurements into wearable devices has extended its accessibility. Although the use of photoplethysmography technology is not new, the available data relating to the validity of measurement are limited, and the range of activities being performed is often restricted to one exercise domain and/or limited intensities. Objective: The primary objective of this study was to assess the validity of the Polar OH1 and Fitbit Charge 3 devices for measuring heart rate during rest, light, moderate, vigorous, and sprint-type exercise. Methods: A total of 20 healthy adults (9 female; height: mean 1.73 [SD 0.1] m; body mass: mean 71.6 [SD 11.0] kg; and age: mean 40 [SD 10] years) volunteered and provided written informed consent to participate in the study consisting of 2 trials. Trial 1 was split into 3 components: 15-minute sedentary activities, 10-minute cycling on a bicycle ergometer, and incremental exercise test to exhaustion on a motorized treadmill (18-42 minutes). Trial 2 was split into 2 components: 4 × 15-second maximal sprints on a cycle ergometer and 4 × 30- to 50-m sprints on a nonmotorized resistance treadmill. Data from the 3 devices were time-aligned, and the validity of Polar OH1 and Fitbit Charge 3 was assessed against Polar H10 (criterion device). Validity was evaluated using the Bland and Altman analysis, Pearson moment correlation coefficient, and mean absolute percentage error. Results: Overall, there was a very good correlation between the Polar OH1 and Polar H10 devices (r=0.95), with a mean bias of −1 beats·min-1 and limits of agreement of −20 to 19 beats·min-1. The Fitbit Charge 3 device underestimated heart rate by 7 beats·min-1 compared with Polar H10, with a limit of agreement of −46 to 33 beats·min-1 and poor correlation (r=0.8). The mean absolute percentage error for both devices was deemed acceptable (<5%). Polar OH1 performed well across each phase of trial 1; however, validity was worse for trial 2 activities. Fitbit Charge 3 performed well only during rest and nonsprint-based treadmill activities. Conclusions: Compared with our criterion device, Polar OH1 was accurate at assessing heart rate, but the accuracy of Fitbit Charge 3 was generally poor. Polar OH1 performed worse during trial 2 compared with the activities in trial 1, and the validity of the Fitbit Charge 3 device was particularly poor during our cycling exercises.

10 February 2023 in JMIR Cardio
Verified
Journal Article
Open access
OGOonagh M. Giggins
Oonagh M. Giggins
JDJulie Doyle
Julie Doyle
SSSuzanne Smith
Suzanne Smith
GVGrainne Vavasour
Grainne Vavasour
OMOrla Moran
Orla Moran
GBGordon Boyle
Gordon Boyle
Background: Exercise-based cardiac rehabilitation (CR) is recommended for coronary heart disease (CHD). However, poor uptake of and poor adherence to CR exercise programs have been reported globally. Delivering CR exercise classes remotely may remove some of the barriers associated with traditional hospital- or center-based CR. Objective: We have developed a bespoke platform, Eastern Corridor Medical Engineering Centre–Cardiac Rehabilitation (ECME-CR), to support remotely delivered CR exercise. This pilot trial sought to test the ECME-CR platform and examine the efficacy and feasibility of a remote CR exercise program compared to a traditional center-based program. Methods: In all, 21 participants with CHD were recruited and assigned to either the intervention or control group. Both groups performed the same 8-week exercise program. Participants in the intervention group took part in web-based exercise classes and used the ECME-CR platform during the intervention period, whereas participants in the control group attended in-person classes. Outcomes were assessed at baseline and following the 8-week intervention period. The primary outcome measure was exercise capacity, assessed using a 6-minute walk test (6MWT). Secondary outcomes included measurement of grip strength, self-reported quality of life, heart rate, blood pressure, and body composition. A series of mixed between-within subjects ANOVA were conducted to examine the mean differences in study outcomes between and within groups. Participant adherence to the exercise program was also analyzed. Results: In all, 8 participants (male: n=5; age: mean 69.7, SD 7.2 years; height: mean 163.9, SD 5.4 cm; weight: mean 81.6, SD 14.1 kg) in the intervention group and 9 participants (male: n=9; age: mean 69.8, SD 8.2 years; height: mean 173.8, SD 5.2 cm; weight: mean 94.4, SD 18.0 kg) in the control group completed the exercise program. Although improvements in 6MWT distance were observed from baseline to follow-up in both the intervention (mean 490.1, SD 80.2 m to mean 504.5, SD 93.7 m) and control (mean 510.2, SD 48.3 m to mean 520.6, SD 49.4 m) group, no significant interaction effect (F1,14=.026; P=.87) nor effect for time (F1,14=2.51; P=.14) were observed. No significant effects emerged for any of the other secondary end points (all P>.0275). Adherence to the exercise program was high in both the intervention (14.25/16, 89.1%) and control (14.33/16, 89.6%) group. No adverse events or safety issues were reported in either group during the study. Conclusions: This pilot trial did not show evidence of significant positive effect for either the remotely delivered or center-based program. The 6MWT may not have been sufficiently sensitive to identify a change in this cohort of participants with stable CHD. This trial does provide evidence that remote CR exercise, supported with digital self-monitoring, is feasible and may be considered for individuals less likely to participate in traditional center-based programs. International Registered Report Identifier (IRRID): RR2-10.2196/31855

18 January 2025 in Oxford Open Digital Health
Verified
Journal Article
Open access
PGPrabhadini Godage
Prabhadini Godage
OGOonagh M. Giggins
Oonagh M. Giggins
JDJulie Doyle
Julie Doyle
ABAnita Byrne
Anita Byrne
Mindfulness-Based Interventions (MBIs) delivered via mobile health (mHealth) platforms have gained attention for improving perinatal psychological health. This review systematically examines the effectiveness of mHealth MBIs in improving perinatal psychological outcomes, including stress, anxiety and depression, with a secondary focus on safety, engagement, acceptability and dropout rates. A systematic search was conducted across PubMed, Cochrane Library, Science Direct, Scopus, ACM Digital Library and IEEE Xplore, along with grey literature, for English-language journal articles from inception until July 2024. All included studies were assessed for methodological quality using standardized critical appraisal instrument. Significant heterogeneity in study designs, program structures and data collection methods precluded meta-analysis, leading to a narrative synthesis of the results. Fifteen studies were included, featuring a mix of quantitative and qualitative designs. Findings indicated that mHealth MBIs demonstrated promise in reducing stress, anxiety and depressive symptoms during pregnancy and postpartum. However, participant engagement in these interventions was influenced by factors such as intervention complexity, user interface challenges and technological issues like app compatibility. Dropouts were commonly attributed to time constraints and technical difficulties, while user feedback emphasized the need for varied and flexible content to sustain interest and perceived effectiveness. Overall, mHealth MBIs offer potential benefits for perinatal psychological health, particularly in reducing stress and anxiety. However, maintaining high engagement and low dropout rates remains a challenge. Future studies should identify optimal intervention formats, enhance adherence and assess long-term impacts of mHealth MBIs to strengthen the evidence base, particularly in diverse settings and for pregnancy-related complications.

MFMatthew James Fraser
Matthew James Fraser
TGTrish Gorely
Trish Gorely
COChris O’malley
Chris O’malley
DMDavid Muggeridge
David Muggeridge
OGOonagh M. Giggins
Oonagh M. Giggins
DCDaniel Crabtree
Daniel Crabtree
Individuals living in rural areas are more likely to experience cardiovascular diseases (CVD) and have increased barriers to regular physical activity in comparison to those in urban areas. This systematic review aimed to understand the types and effects of home-based connected health technologies, used by individuals living in rural areas with CVD. The inclusion criteria included technology deployed at the participant’s home and could be an mHealth (smart device, fitness tracker or app) or telehealth intervention. Nine electronic databases were searched across the date range January 1990–June 2021. A total of 207 full texts were screened, of which five studies were included, consisting of 603 participants. Of the five studies, four used a telehealth intervention and one used a form of wearable technology. All interventions which used a form of telehealth found a reduction in overall healthcare utilisation, and one study found improvements in CVD risk factors. Acceptability of the technologies was mixed, in some studies barriers and challenges were cited. Based on the findings, there is great potential for implementing connected health technologies, but due to the low number of studies which met the inclusion criteria, further research is required within rural areas for those living with cardiovascular disease.

1 September 2022 in JMIR Formative Research
Verified
Journal Article
Open access
OGOonagh M. Giggins
Oonagh M. Giggins
JDJulie Doyle
Julie Doyle
SSSuzanne Smith
Suzanne Smith
DCDaniel Crabtree
Daniel Crabtree
MFMatthew James Fraser
Matthew James Fraser
Background: Wrist-worn devices that incorporate photoplethysmography (PPG) sensing represent an exciting means of measuring heart rate (HR). A number of studies have evaluated the accuracy of HR measurements produced by these devices in controlled laboratory environments. However, it is also important to establish the accuracy of measurements produced by these devices outside the laboratory, in real-world, consumer use conditions. Objective: This study sought to examine the accuracy of HR measurements produced by the Withings ScanWatch during free-living activities. Methods: A sample of convenience of 7 participants volunteered (3 male and 4 female; mean age 64, SD 10 years; mean height 164, SD 4 cm; mean weight 77, SD 16 kg) to take part in this real-world validation study. Participants were instructed to wear the ScanWatch for a 12-hour period on their nondominant wrist as they went about their day-to-day activities. A Polar H10 heart rate sensor was used as the criterion measure of HR. Participants used a study diary to document activities undertaken during the 12-hour study period. These activities were classified according to the 11 following domains: desk work, eat or drink, exercise, gardening, household activities, self-care, shopping, sitting, sleep, travel, and walking. Validity was assessed using the Bland-Altman analysis, concordance correlation coefficient (CCC), and mean absolute percentage error (MAPE). Results: Across all activity domains, the ScanWatch measured HR with MAPE values <10%, except for the shopping activity domain (MAPE=10.8%). The activity domains that were more sedentary in nature (eg, desk work, eat or drink, and sitting) produced the most accurate HR measurements with a small mean bias and MAPE values <5%. Moderate to strong correlations (CCC=0.526-0.783) were observed between devices for all activity domains, except during the walking activity domain, which demonstrated a weak correlation (CCC=0.164) between devices. Conclusions: The results of this study show that the ScanWatch measures HR with a degree of accuracy that is acceptable for general consumer use; however, it would not be suitable in circumstances where more accurate measurements of HR are required, such as in health care or in clinical trials. Overall, the ScanWatch was less accurate at measuring HR during ambulatory activities (eg, walking, gardening, and household activities) compared to more sedentary activities (eg, desk work, eat or drink, and sitting). Further larger-scale studies examining this device in different populations and during different activities are required.

1 January 2019 in Gerontology and Geriatric Medicine
Verified
Journal Article
Open access
PDF file
OGOonagh M. Giggins
Oonagh M. Giggins
JDJulie Doyle
Julie Doyle
KHKen Hogan
Ken Hogan
MGMable George
Mable George
Purpose: Achieving adequate levels of illumination to stimulate the circadian system can be difficult in a nursing home. The aim of this study was to examine the impact that a 4-week cycled lighting intervention had on activity, sleep, and mood in older adults living in a nursing home. Patients and methods: Ten residents were given an activity monitor to objectively measure activity and sleep, and subjective mood scores were also recorded during the study period. The cycled lighting intervention was designed to mimic normal natural daylight. Results: Some participants responded positively to the lighting intervention showing improvements in activity levels, sleep, and mood, while others showed no change or a continued decline. Conclusion: Although the results are inconclusive, a cycled lighting intervention remains a potentially promising intervention in the nursing home setting. Further studies with more robust measurements and a larger, more homogeneous cohort are required to investigate this further.