The increasing integration of large-scale electricity generation from renewable energy sources in the grid requires support through cheap, reliable, and accessible bulk energy storage technologies, delivering large amounts of electricity both quickly and over extended periods. Compressed air energy storage (CAES) represents such a storage option, with three commercial facilities using salt caverns for storage operational in Germany, the US, and Canada, with CAES now being actively considered in many countries. Massively bedded halite deposits exist in the UK and already host, or are considered for, solution-mined underground gas storage (UGS) caverns. We have assessed those with proven UGS potential for CAES purposes, using a tool developed during the EPSRC-funded IMAGES project, equations for which were validated using operational data from the Huntorf CAES plant. From a calculated total theoretical ‘static’ (one-fill) storage capacity exceeding that of UK electricity demand of ≈300 TWh in 2018, filtering of results suggests a minimum of several tens of TWh exergy storage in salt caverns, which when co-located with renewable energy sources, or connected to the grid for off-peak electricity, offers significant storage contributions to support the UK electricity grid and decarbonisation efforts.
16 November 2020 in Quarterly Journal of Engineering Geology and Hydrogeology
Low-temperature heat recovery, cooling and storage schemes, using abandoned flooded mine workings, are a viable option for low-carbon heating solutions within many abandoned British coalfields. The temperature of mine water is a useful parameter, coupled with depth to water, sustainable yield and recharge potential, to identify suitable locations and calculate the likely performance of heat recovery schemes. This paper aims to provide the first mapping and synthesis of the temperature of Britain's coalfields to support this emerging technology. Using the best available evidence, a median geothermal gradient of 24.1°C km −1 was calculated for the British coalfields. However, geothermal gradients between separate coalfields can vary from 17.3 to 34.3°C km −1 . The North East, Cumbria and Yorkshire coalfields all have mean geothermal gradients generally >30°C km −1 , whereas geothermal gradients of generally <23°C km −1 are measured in the Warwickshire, South Wales, Staffordshire, Douglas and Fife coalfields. Active dewatering schemes are shown to locally increase the apparent measured geothermal gradient by ingress and mixing of deeper water into the pumping shafts. This baseline spatial mapping and synthesis of coalfield temperatures offers significant benefit to those planning, designing and regulating heat recovery and storage in Britain's abandoned coalfields.
An assessment of the engineered geothermal system (EGS) resource base that might be available for the generation of electricity for Great Britain has been undertaken by adopting a globally self-consistent protocol that if universally adopted, would allow estimates of EGS made for different countries and regions to be comparable. Maximum estimated temperatures at depths of 5 and 7 km are greater than 200 and 300 °C respectively, a considerable increase over previous estimates. The total heat in place in the basement, to a depth of 9.5 km that is theoretically available for EGS is 357,197 EJ. If it were possible to develop just 2% of this resource, this would be equivalent to 1242 times the final UK energy consumption in 2015. The theoretical and technical potential power has been calculated from the available heat in place. The total technical potential power, to a depth of 6.5 km, is 222,393 MWe and represents just 0.4% of the theoretical potential power. Current EGS exploitation is more likely to be restricted to a depths of around 4.5 km and reservoir temperatures greater than 175 °C. In which case technical potential power is mainly restricted to regions of high heat producing granites and represents a total technical potential power of 2280 MWe. However, improvements in drilling technology are expected to enable economic drilling to depths of 7 km or greater that will enable EGS exploitation in all regions of Great Britain.
The Variscides of southeast England are buried beneath post-Carboniferous cover. Interpretations of the basement are based mainly on deep boreholes. Geophysical signatures from the basement are contained within the regional gravity and magnetic data. A gravity stripping exercise has been undertaken to remove the gravitational effect of the post-Variscan cover to generate a residual gravity map. This map is interpreted along with integrated potential field modelling along four long interconnected profiles and compared with a revised pre-Permian subcrop map. The magnetic evidence suggests that Precambrian magnetic basement of the Midlands Microcraton has been buried southwards by north-vergent Variscan thusting over the foreland. North of the Variscan Front, short-wavelength anomalies superimposed upon this deep Precambrian source are due to shallower Silurian and Carboniferous volcanic rocks. Many residual gravity lows within the Rhenohercynian zone may be related to thick, low-density Devonian basins. In the English Channel a change in geophysical signature occurs north of the Portland–Wight Fault, coinciding with phyllites in the basement. Models are presented in which the English Channel magnetic anomalies originate within the pre-Permian basement. Comparisons with anomalies in the Southwestern Approaches suggest that the Portland–Wight Thrust is a terrane boundary, possibly a subduction-related suture, implying southerly directed Variscan subduction.
23 October 2020 in Quarterly Journal of Engineering Geology and Hydrogeology
The Mercia Mudstone Group (MMG) crops out extensively across England and Wales and its thermal properties are required for the design of infrastructure such as ground source heating and cooling schemes and electrical cable conduits. Data from the literature and new data from a borehole core have been compiled to generate an updated range of thermal conductivities related to rock type and the lithostratigraphy. These indicate a total range in saturated vertical thermal conductivity of 1.67–3.24 W m −1 K −1 , comprising 1.67–2.81 W m −1 K −1 for mudstones, 2.12–2.41 W m −1 K −1 for siltstones and 2.3–3.24 W m −1 K −1 for sandstones. These data are all from measurements on samples and there will be uncertainty when considering the thermal properties of the rock mass owing to micro- and macrostructural features. Geometric mean modelling of thermal conductivity based on mineralogy has overestimated the thermal conductivity. Correction factors for the modelled thermal conductivities have been calculated to allow a first estimate of MMG thermal conductivities when only mineralogical data are available. Measured thermal diffusivities from the borehole core were in the range of 0.63–3.07 × 10 −6 m 2 s −1 and are the first measured thermal diffusivities to be reported for the MMG.
11 December 2015 in Proceedings of the Geologists' Association