Feng Wu

Feng Wu


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2018 in Allergy, Asthma & Clinical Immunology
Verified
Journal Article
Open access
PDF file
JGjie gao
jie gao
FWFeng Wu
Feng Wu
The fractional exhaled nitric oxide (FeNO) and blood eosinophils are biomarkers of eosinophilic airway inflammation used in the diagnosis and management of asthma, although induced sputum is the gold standard test for phenotypic asthma. Nevertheless, the clinical application of the correlation between sputum eosinophils, FeNO and blood eosinophils is controversial. To investigate the clinical application of the correlation between sputum eosinophils, FeNO and blood eosinophils with uncontrolled asthmatic patients. It also examined the relationships between these biomarkers in bronchial reversibility and bronchial hyper-responsiveness (BHR). This study evaluated 75 uncontrolled asthmatic patients (symptom control and future risk of adverse outcomes). All patients underwent the following on the same day: FeNO, spirometry, BHR or bronchodilator reversibility, sputum induction and blood collection. Eosinophilic airway inflammation was defined as sputum eosinophils ≥ 2.5% or FeNO levels ≥ 32 parts per billion (ppb). A significant positive relationship was between percentage of sputum eosinophils and FeNO (r = 0.4556; p < 0.0001) and percentage of blood eosinophils (r = 0.3647; p = 0.0013), and a significant negative correlation was between percentage of sputum neutrophils and FeNO (r = − 0.3653; p = 0.0013). No relationship between FeNO and percentage of blood eosinophils (p = 0.5801). ROC curve analysis identified FeNO was predictive of sputum eosinophilia [area under the curve (AUC) 0.707, p = 0.004] at a cutoff point of 35.5 ppb (sensitivity = 67.3%, specificity = 73.9%). Percentage of blood eosinophils was also highly predictive with an AUC of 0.73 (p = 0.002) at a cut-off point of 1.5%, sensitivity and specificity were 61.5 and 78.3%, respectively. Although the sputum neutrophil percentage was correlated with FeNO, ROC curve of these parameters did not show useful values (AUC = 0.297, p = 0.003; AUC = 0.295, p = 0.021). Blood eosinophils and FeNO can accurately predict eosinophilic airway inflammation in uncontrolled asthmatic patients. FeNO is poor surrogates for sputum neutrophils and blood eosinophils. The FeNO level and blood eosinophils, which determine an optimal cutoff for sputum eosinophilia, need more studies.

1 December 2020 in Journal of Inflammation Research
Verified
Journal Article
Open access
PDF file
JGjie gao
jie gao
FWFeng Wu
Feng Wu
SWSifang Wu
Sifang Wu
XYXing Yang
Xing Yang
Background: Measurement of sputum is used to define airway inflammatory phenotypes. Cough variant asthma (CVA) is considered to be the initial stage of classic asthma (CA). The aim of this study was to describe the association between the different subtypes of CVA and CA. Methods: A total of 459 patients with CVA and CA were screened for the study. All included patients performed spirometry, underwent a bronchial challenge with methacholine and induced sputum according to the guidelines. Results: A higher frequency of female patients were found with CVA and the eosinophilic airway inflammation of CVA than in CA and the noneosinophilic airway inflammation of CA (p=0.004 and p=0.024, respectively). Bronchial hyper-responsiveness (BHR) was lower in eosinophilic CVA and CA (p=0.006), while no difference was found in noneosinophilic CVA and CA. Association between the percentage of sputum eosinophils and the FEV1 level fell below 20% of the baseline value (PD20) in CVA and CA (r= − 0.1245, p=0.0357 and r= − 0.2148, p=0.0014, respectively). Conclusion: Eosinophilia may be associated with more severe disease, yet there was no difference in spirometry between the eosinophilic and noneosinophilic groups, and the BHR difference was not dramatic.

1 April 2017 in International Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Open access
PDF file
JGjie gao
jie gao
MZMin Zhang
Min Zhang
LZLiqin Zhou
Liqin Zhou
XYXing Yang
Xing Yang
HWHaigui Wu
Haigui Wu
FWFeng Wu
Feng Wu
Correlation between fractional exhaled nitric oxide and sputum eosinophilia in exacerbations of COPD Jie Gao,1 Min Zhang,2 Liqin Zhou,1 Xing Yang,1 Haigui Wu,1 Jianfang Zhang,1 Feng Wu1 1Department of Respiratory Medicine, 2Internal Medicine-Cardiovascular Department, The Third People’s Hospital, Guangzhou Medical College, Huizhou, People’s Republic of China Introduction: Measurements of eosinophils in induced sputum and fractional exhaled nitric oxide (FeNO) are noninvasive biomarkers for assessing airway inflammation phenotypes in chronic obstructive pulmonary disease (COPD). Nevertheless, the clinical application of the correlation between FeNO levels and sputum eosinophilia is controversial. The study aimed to investigate the correlation and predictive relationship between FeNO levels and sputum eosinophils in patients with COPD exacerbation. It also examined the relationship between FeNO levels and blood eosinophil percentage. Methods: A total of 163 patients with COPD exacerbation were included in the cross-sectional study. All patients underwent the following on the same day: FeNO test, spirometry, bronchodilator reversibility test, induced sputum, and routine blood test. They were classified as eosinophilic group or noneosinophilic group based on sputum eosinophilic percentage (=2.5%)/FeNO levels (=32 parts per billion [ppb]). Results: FeNO levels and blood eosinophilic percentage were higher in patients with sputum eosinophilia (n=62) compared to those without (31.35 ppb versus 21.43 ppb, P=0.015; 2.71% versus 0.98%, P<0.0001, respectively). Sputum eosinophilic percentage was higher with raised FeNO (n=34) compared to those with FeNO <32 ppb (5.12% versus 3.12%, P=0.007). Eosinophils in induced sputum correlated with both FeNO levels (ρ=0.221, P=0.005) and blood eosinophilic percentage (ρ=0.399, P<0.001). There was no relationship between FeNO and blood eosinophilic percentage. Blood eosinophilic percentage was predictive of sputum eosinophilia (95% confidence interval [CI] =0.65–0.81, P<0.001) at a cutoff point of 0.65% (sensitivity =73%, specificity =61.3%). FeNO levels were predictive of sputum eosinophilia (95% CI =0.53–3,071, P=0.012) at a cutoff point of 17.5 ppb (sensitivity =65.1%, specificity =56.4%). Conclusion: The clinical relevance of this study provides evidence that inflammatory biomarkers, including sputum eosinophilic percentage, FeNO level, and blood eosinophilic percentage, can be used to positively diagnose eosinophilic COPD. The FeNO level and blood eosinophilic counts/percentage, which determine an optimal cutoff for sputum eosinophilia, need more studies. Keywords: fractional exhaled nitric oxide, eosinophils in induced sputum, blood eosinophil percentage, chronic obstructive pulmonary disease

1 September 2017 in International Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Open access
PDF file
JGjie gao
jie gao
WZWutie Zhou
Wutie Zhou
BCBida Chen
Bida Chen
WLWeiming Lin
Weiming Lin
SWSifang Wu
Sifang Wu
FWFeng Wu
Feng Wu
Introduction: Cell count in induced sputum is a noninvasive biomarker to assess airway inflammation phenotypes. Accordingly, sputum cell counts are extensively used in the treatment of asthma and COPD. Nevertheless, the clinical application of sputum cell counts in patients with asthma–COPD overlap (ACO) remains elusive. The aim of this study was to investigate sputum cell counts in patients with ACO which are different from those in patients with asthma and COPD and also to examine the relationship between sputum cell counts in bronchial reversibility and bronchial hyperresponsiveness (BHR). Patients and methods: A total of 374 patients participated in the study, including 142 patients with asthma, 160 patients with COPD and 72 patients with ACO. All patients underwent the following tests on the same day: pulmonary function test (PFT), BHR test or bronchodilator reversibility test and inducing sputum. They were classified into the asthma group, COPD group or ACO group based on a clinical history, PFT values and BHR test or bronchodilator reversibility test. Results: The three groups had different PFT values (p<0.001) except for forced vital capacity (FVC) between the asthma and ACO groups (p=0.378). The sputum levels of eosinophil% were decreased in patients with COPD when compared with those in patients with asthma and ACO (p<0.001 and p<0.001, respectively). There was a difference in sputum neutrophil% and macrophage% counts among the three groups (p<0.001 and p<0.001, respectively); there was no difference in sputum eosinophil% counts between patients with ACO and asthma (p=0.668) and there was no difference in the percentage of induced sputum cells between the stage of airway obstruction and the stage of BHR. Conclusion: The clinical relevance of this study provides evidence that sputum cell counts as an inflammatory biomarker could carry some information to distinguish ACO, asthma and COPD, and these biomarkers need more studies to provide diagnostic value in the differentiation between ACO, asthma and COPD.

3 February 2021 in BMC Pulmonary Medicine
Verified
Journal Article
Open access
PDF file
JGJie Gao
Jie Gao
HWHaigui Wu
Haigui Wu
FWFeng Wu
Feng Wu
Background: Cough variant asthma (CVA) is one of the special populations of asthma. The aim of the study was to compare small airways, the degree of bronchial hyperresponsiveness (BHR) and airway inflammatory subtypes between CVA and classic asthma (CA), and investigate the relationship between these markers to determine the accuracy as indicators of CVA. Methods: A total of 825 asthmatic patients participated in the study and 614 were included. 614 patients underwent spirometry and a bronchial challenge with methacholine and 459 patients performed induction sputum cell test. Results: The number of CVA patients showed less small airway dysfunction than those of CA patients (p < 0.005). The degree of small airways dysfunction was higher in the CA group compared with the CVA group (p < 0.001). Small airways dysfunction was severer in the eosinophilic airway inflammatory subtype compared with other subtypes (p < 0.05).The area under curve of MMEF, FEF50 and FEF75 (% predicted) was 0.615, 0.621, 0.606, respectively. 0.17mcg of PD20 and 4.7% of sputum eosinophils was the best diagnostic value for CVA with an AUC of 0.582 and 0.575 (p = 0.001 and p = 0.005, respectively). Conclusions: The eosinophilic airway inflammatory subtype may be increased small airway dysfunction. The value of small airways, BHR and induction sputum cells in CVA prediction, which reflected significant, but not enough to be clinically useful.

24 February 2020 in BMC Pulmonary Medicine
Verified
Journal Article
Open access
PDF file
JGjie gao
jie gao
BCBida Chen
Bida Chen
SWSifang Wu
Sifang Wu
FWFeng Wu
Feng Wu
Background: Measurement of sputum is frequently used to define airway inflammatory subtypes. The venous blood cell is a reliable and simple biomarker, may be used as an alternative procedure to reflect the subtypes. For the aim of verifying the hypothesis that venous blood cell can quantify sputum inflammatory cell to access the airway subtypes in chronic obstructive pulmonary disease of acute exacerbations (AECOPD) and to ascertain the accuracy of the blood cell biomarker. Methods: This study evaluated 287 patients with COPD exacerbations and all four tests were performed on the same day, which are lung function test, bronchodilator reversibility test, sputum cell analysis and blood routine examination. Results: There was a correlation between sputum eosinophils and blood eosinophils, blood cells derived ratios. There was a weaker relationship to neutrophils between sputum and blood. Sputum neutrophils had not any association with neutrophil/macrophage ratio (NMR) and eosinophil/lymphocyte ratio (ELR) in blood. Blood eosinophils percentage was predictive for eosinophilic COPD exacerbations with an area under the curve (AUC) of 0.672 (p = 0.012). The optimum cutpoint for blood eosinophils percentage was 0.55%. Blood eosinophils absolute count was also predictive sputum eosinophilia at 0.35 × 109/L (AUC = 0.626, p = 0.025). ELR, eosinophil/monocyte ratio (EMR) and eosinophil/neutrophil ratio (ENR) in blood were higher in COPD exacerbations with mixed granulocytic and eosinophilic subtypes. Conclusion: Eosinophils/neutrophils count parameters were relationship between blood and sputum. Eosinophils in blood and the ratios (ENR, EMR and ELR) may be utilized to assess eosinophilic airway inflammation in COPD exacerbations. Due to weak relationship and poor predictive ability, more researches should be required.