Untethered robots miniaturized to the length scale of millimeter and below attract growing attention for the prospect of transforming many aspects of health care and bioengineering. As the robot size goes down to the order of a single cell, previously inaccessible body sites would become available for high-resolution in situ and in vivo manipulations. This unprecedented direct access would enable an extensive range of minimally invasive medical operations. Here, we provide a comprehensive review of the current advances in biomedical untethered mobile milli/microrobots. We put a special emphasis on the potential impacts of biomedical microrobots in the near future. Finally, we discuss the existing challenges and emerging concepts associated with designing such a miniaturized robot for operation inside a biological environment for biomedical applications.
Untethered mobile microrobots has the potential to leverage minimally invasive theranostic functions precisely and efficiently in hard-to-reach, confined, and delicate inner body sites. However, such a complex task requires an integrated design and engineering, where powering, control, environmental sensing, medical functionality and biodegradability need to be considered altogether. The present study reports a hydrogel-based, magnetically powered and controlled, enzymatically degradable microswimmer, which is responsive to the pathological markers in its microenvironment for theranostic cargo delivery and release tasks. We design a double-helical architecture enabling volumetric cargo loading and swimming capabilities under rotational magnetic fields, and 3D printed such optimized 3D microswimmer (length: 20 µm and diameter: 6 µm) using two-photon polymerization from a magnetic precursor suspension comprised from gelatin methacryloyl and biofunctionalized superparamagnetic iron oxide nanoparticles. At normal physiological concentrations, we show that matrix metalloproteinase-2 (MMP-2) enzyme could entirely degrade the microswimmer in 118 h to solubilized non-toxic products. The microswimmer rapidly responds to the pathological concentrations of MMP-2 by swelling, and thereby boosting the release of the embedded cargo molecules. In addition to delivery of the drug type of therapeutic cargo molecules completely to the given microenvironment after full degradation, microswimmer can also release other functional cargos. As an example demonstration, Anti-ErbB 2 antibody-tagged magnetic nanoparticles are released from the fully degraded microswimmers for targeted labeling of SKBR3 breast cancer cells in vitro towards a potential future scenario of medical imaging of remaining cancer tissue sites after a microswimmer-based therapeutic delivery operation.
Untethered micron-scale mobile robots can navigate and non-invasively perform specific tasks inside unprecedented and hard-to-reach inner human body sites and inside enclosed organ-on-a-chip microfluidic devices with live cells.
Untethered mobile microrobots have the potential to transform medicine radically. Their small size and wireless mobility can enable access to and navigation in confined, small, hard-to-reach, and sensitive inner body sites, where they can provide new ways of minimally invasive interventions and targeted diagnosis and therapy down to the cellular length scales with high precision and repeatability. The exponential recent progress of the field at the preclinical level raises anticipations for their near-future clinical prospects. To pave the way for this transformation to happen, however, the formerly proposed microrobotic system designs need a comprehensive review by including essential aspects that a microrobot needs to function properly and safely in given in vivo conditions of a targeted medical problem. The present review provides a translational perspective on medical microrobotics research with an application-oriented, integrative design approach. The blueprint of a medical microrobot needs to take account of microrobot shape, material composition, manufacturing technique, permeation of biological barriers, deployment strategy, actuation and control methods, medical imaging modality, and the execution of the prescribed medical tasks altogether at the same time. The incorporation of functional information pertaining each such element to the physical design of the microrobot is highly dependent on the specific clinical application scenario. We discuss the complexity of the challenges ahead and the potential directions to overcome them. We also throw light on the potential regulatory aspects of medical microrobots toward their bench-to-bedside translation. Such a multifaceted undertaking entails multidisciplinary involvement of engineers, materials scientists, biologists and medical doctors, and bringing their focus on specific medical problems where microrobots could make a disruptive or radical impact.