Catia Grimani

Prof. Catia Grimani

University of Urbino Carlo Bo

Research Focus & Metrics

Academic Career Length

38Years (1989-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 June 2016 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
MAM. Armano
M. Armano
HAH. Audley
H. Audley
GAG. Auger
G. Auger
JBJONATHON BAIRD
JONATHON BAIRD
MBM. Bassan
M. Bassan
PZP. Zweifel
P. Zweifel
We report the first results of the LISA Pathfinder in-flight experiment. The results demonstrate that two free-falling reference test masses, such as those needed for a space-based gravitational wave observatory like LISA, can be put in free fall with a relative acceleration noise with a square root of the power spectral density of 5.2±0.1  fm s−2/Hz, or (0.54±0.01)×10−15  g/Hz, with g the standard gravity, for frequencies between 0.7 and 20 mHz. This value is lower than the LISA Pathfinder requirement by more than a factor 5 and within a factor 1.25 of the requirement for the LISA mission, and is compatible with Brownian noise from viscous damping due to the residual gas surrounding the test masses. Above 60 mHz the acceleration noise is dominated by interferometer displacement readout noise at a level of (34.8±0.3)  fm/Hz, about 2 orders of magnitude better than requirements. At f≤0.5  mHz we observe a low-frequency tail that stays below 12  fm s−2/Hz down to 0.1 mHz. This performance would allow for a space-based gravitational wave observatory with a sensitivity close to what was originally foreseen for LISA.

20 March 2000 in The Astrophysical Journal
Verified
Journal Article
Closed access
PDF file
MBM. Boezio
M. Boezio
PCP. Carlson
P. Carlson
TFT. Francke
T. Francke
NWN. Weber
N. Weber
MSM. Suffert
M. Suffert
SSS. J. Stochaj
S. J. Stochaj
We report on a new measurement of the cosmic-ray electron and positron spectra. The data were collected by the balloon-borne experiment CAPRICE94, which was flown from Lynn Lake, Canada, on 1994 August 8-9 at an altitude corresponding to 3.9 g cm-2 of average residual atmosphere. The experiment used the NMSU-WIZARD/CAPRICE94 balloon-borne magnet spectrometer equipped with a solid radiator Ring Imaging Cerenkov (RICH) detector, a time-of-flight system, a tracking device consisting of drift chambers and multiwire proportional chambers, and a silicon-tungsten calorimeter. This was the first time a RICH detector was used together with an imaging calorimeter in a balloon-borne experiment. A total of 3211 electrons, with a rigidity at the spectrometer between 0.3 and 30 GV, and 734 positrons, between 0.3 and 10 GV, were identified with small backgrounds from other particles. The absolute energy spectra were determined in the energy region at the top of the atmosphere between 0.46 and 43.6 GeV for electrons and between 0.46 and 14.6 GeV for positrons. We found that the observed positron spectrum and the positron fraction are consistent with a pure secondary origin. A comparison of the theoretically predicted interstellar spectrum of electrons shows that the injection spectrum of primary electrons is steeper than that of the nucleonic components of cosmic rays. Furthermore, the observed electron and positron spectra can be reproduced from the interstellar spectra by a spherically symmetric model for solar modulation; hence, the modulation is independent of the sign of the particle charge

22 November 1999 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
JKJ. Kremer
J. Kremer
MBM. Boezio
M. Boezio
MAM. L. Ambriola
M. L. Ambriola
GBG. Barbiellini
G. Barbiellini
SBS. Bartalucci
S. Bartalucci
NZN. Zampa
N. Zampa
We report new measurements of the muon spectra and the muon charge ratio at ground level in the momentum range from 200MeV/c to 120GeV/c for two different geomagnetic locations. Above 0.9GeV/c the absolute spectra measured in the two locations are in good agreement and are about 10% to 15% lower than previous experimental results. At lower momenta the data show latitude dependent geomagnetic effects. These observations are important for the understanding of the observed neutrino anomaly.

20 September 1997 in The Astrophysical Journal
Verified
Journal Article
Open access
PDF file
MBM. Boezio
M. Boezio
PCP. Carlson
P. Carlson
TFT. Francke
T. Francke
NWN. Weber
N. Weber
MSM. Suffert
M. Suffert
SSS. J. Stochaj
S. J. Stochaj
We report on the absolute antiproton flux and the antiproton to proton ratio in the energy range 0.62-3.19 GeV at the top of the atmosphere, measured by the balloon-borne experiment CAPRICE flown from Lynn Lake, Manitoba, Canada, on 1994 August 8-9. The experiment used the New Mexico State University WiZard/CAPRICE balloon-borne magnet spectrometer equipped with a solid radiator Ring Imaging Cherenkov (RICH) detector and a silicon-tungsten calorimeter for particle identification. This is the first time a RICH is used together with an imaging calorimeter in a balloon experiment, and it allows antiprotons to be clearly identified over the rigidity range 1.2-4 GV. Nine antiprotons were identified in the energy range 0.62-3.19 GeV at the top of the atmosphere. The data were collected over 18 hr at a mean residual atmosphere of 3.9 g cm-2. The absolute antiproton flux is consistent with a pure secondary production of antiprotons during the propagation of cosmic rays in the Galaxy

26 April 2017 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
MAM. Armano
M. Armano
HAH. Audley
H. Audley
GAG. Auger
G. Auger
JBJONATHON BAIRD
JONATHON BAIRD
PBP. Binetruy
P. Binetruy
LCLISA Pathfinder Collaboration
LISA Pathfinder Collaboration
We report on electrostatic measurements made on board the European Space Agency mission LISA Pathfinder. Detailed measurements of the charge-induced electrostatic forces exerted on free-falling test masses (TMs) inside the capacitive gravitational reference sensor are the first made in a relevant environment for a space-based gravitational wave detector. Employing a combination of charge control and electric-field compensation, we show that the level of charge-induced acceleration noise on a single TM can be maintained at a level close to 1.0  fm s−2 Hz−1/2 across the 0.1–100 mHz frequency band that is crucial to an observatory such as the Laser Interferometer Space Antenna (LISA). Using dedicated measurements that detect these effects in the differential acceleration between the two test masses, we resolve the stochastic nature of the TM charge buildup due to interplanetary cosmic rays and the TM charge-to-force coupling through stray electric fields in the sensor. All our measurements are in good agreement with predictions based on a relatively simple electrostatic model of the LISA Pathfinder instrument.

23 February 2017 in arXiv
Verified
Preprint
Open access
PDF file
PSPau Amaro Seoane
Pau Amaro Seoane
HAHeather Audley
Heather Audley
SBStanislav Babak
Stanislav Babak
JBJohn Baker
John Baker
EBEnrico Barausse
Enrico Barausse
PZPeter Zweifel
Peter Zweifel
Following the selection of The Gravitational Universe by ESA, and the successful flight of LISA Pathfinder, the LISA Consortium now proposes a 4 year mission in response to ESA's call for missions for L3. The observatory will be based on three arms with six active laser links, between three identical spacecraft in a triangular formation separated by 2.5 million km. LISA is an all-sky monitor and will offer a wide view of a dynamic cosmos using Gravitational Waves as new and unique messengers to unveil The Gravitational Universe. It provides the closest ever view of the infant Universe at TeV energy scales, has known sources in the form of verification binaries in the Milky Way, and can probe the entire Universe, from its smallest scales near the horizons of black holes, all the way to cosmological scales. The LISA mission will scan the entire sky as it follows behind the Earth in its orbit, obtaining both polarisations of the Gravitational Waves simultaneously, and will measure source parameters with astrophysically relevant sensitivity in a band from below $10^{-4}\,$Hz to above $10^{-1}\,$Hz.