James Wilson

Mr. James Wilson


Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2005 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
CRCeon Ramon
Ceon Ramon
HPHubert Preissl
Hubert Preissl
PMPam Murphy
Pam Murphy
JWJames Wilson
James Wilson
CLCurtis Lowery
Curtis Lowery
HEHari Eswaran
Hari Eswaran
Background: Our objective was to quantify and compare the extent of synchronization of the spatial-temporal myometrial activity over the human uterus before and during a contraction using transabdominal magnetomyographic (MMG) recordings. Synchronization can be an important indicator for the quantification of uterine contractions. Methods: The spatialtermporal myometrial activity recordings were performed using a 151-channel noninvasive magnetic sensor system called SARA. This device covers the entire pregnant abdomen and records the magnetic field corresponding to the electrical activity generated in the uterine myometrium. The data was collected at 250 samples/sec and was resampled with 25 samples/sec and then filtered in the band of 0.1–0.2 Hz to study the primary magnetic activity of the uterus related to contractions. The synchronization between a channel pair was computed. It was inferred from a statistical tendency to maintain a nearly constant phase difference over a given period of time even though the analytic phase of each channel may change markedly during that time frame. The analytic phase was computed after taking Hilbert transform of the magnetic field data. The process was applied on the pairs of magnetic field traces (240 sec length) with a stepping window of 20 sec duration which is long enough to cover two cycle of the lowest frequency of interest (0.1 Hz). The analysis was repeated by stepping the window at 10 sec intervals. The spatial patterns of the synchronization indices covering the anterior transabdominal area were computed. For this, regional coil-pairs were used. For a given coil, the coil pairs were constructed with the surrounding six coils. The synchronization indices were computed for each coil pair, averaged over the 21 coil-pairs and then assigned as the synchronization index to that particular coil. This procedure was tested on six pregnant subjects at the gestational age between 29 and 40 weeks admitted to the hospital for contractions. The RMS magnetic field for each coil was also computed. Results: The results show that the spatial patterns of the synchronization indices change and follow the periodic pattern of the uterine contraction cycle. Spatial patterns of synchronization indices and the RMS magnetic fields show similarities in few window frames and also show large differences in few other windows. For six subjects, the average synchronization indices were: 0.346 ± 0.068 for the quiescent baseline period and 0.545 ± 0.022 at the peak of the contraction. Discussion: These results show that synchronization indices and their spatial distributions depict uterine contractions and relaxations.

22 April 2008 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
JWJames Wilson
James Wilson
RGR. B. Govindan
R. B. Govindan
JHJeff O. Hatton
Jeff O. Hatton
CLCurtis L. Lowery
Curtis L. Lowery
HPHubert Preissl
Hubert Preissl
Fetal magnetocardiography provides reliable signals of the fetal heart dynamics with high temporal resolution that can be used in a clinical setting. We present a robust Hilbert transform method for extraction of the fetal heart rate. Our method may be applied to signals derived from a single channel or an array of channels. In the case of multichannel data, the channels can be combined to improve signal-to-noise ratio for the extraction of fetal heart data. The method is inherently insensitive to fetal position or movement and, in addition, can be automated. We demonstrate that the determination of R-wave timing is relatively insensitive to waveform morphology. The method can also be applied if the data were preprocessed by independent component analysis (ICA). We compared the Hilbert method, ICA, ICA + Hilbert, and raw signals and found that the Hilbert method gave the best overall performance. We demonstrated that there were approximately 171 errors in 46 789 fetal heart beats.

1 December 1990 in Regulatory Toxicology and Pharmacology
Verified
Journal Article
Closed access
JAJ. Ashby
J. Ashby
NDN.G. Doerrer
N.G. Doerrer
FFF.G. Flamm
F.G. Flamm
JHJ.E. Harris
J.E. Harris
DHD.H. Hughes
D.H. Hughes
JWJames Wilson
James Wilson

22 December 2008 in Physiological Measurement
Verified
Journal Article
Closed access
JWJames Wilson
James Wilson
AAA J Adams
A J Adams
PMP Murphy
P Murphy
HEH Eswaran
H Eswaran
HPH Preissl
H Preissl
The design, safety analysis and performance of a fetal visual stimulation system suitable for fetal and neonatal magnetoencephalography studies are presented. The issue of fetal, neonatal and maternal safety is considered and the maximum permissible exposure is computed for the maternal skin and the adult eye. The risk for neonatal eye exposure is examined. It is demonstrated that the fetus, neonate and mother are not at risk.

18 August 2009 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
SVSrinivasan Vairavan
Srinivasan Vairavan
HEHari Eswaran
Hari Eswaran
NHNaim Haddad
Naim Haddad
DRDouglas F. Rose
Douglas F. Rose
HPHubert Preissl
Hubert Preissl
RGRathinaswamy B. Govindan
Rathinaswamy B. Govindan
The discontinuous patterns in neonatal magnetoencephalographic (MEG) data are quantified with a novel Hilbert phase (HP) based approach. The expert neurologists' scores were used as the gold standard. The performance of this approach was analyzed using a receiver operating characteristic (ROC) curve, and it was compared with two other approaches, namely spectral ratio (SR) and discrete wavelet transform (DWT) that have been proposed for the detection of discontinuous patterns in neonatal EEG. The area under the ROC curve (AUC) was used as a performance measure. AUCs obtained for SR, HP, and DWT were 0.87, 0.80, and 0.56, respectively. Although the performance of HP was lower than SR, it carries information about the frequency content of the signal that helps to distinguish brain patterns from artifacts such as cardiac residuals. Based on this property, the HP approach was extended to fetal MEG data. Further, using the frequency property of the HP approach, burst duration and interburst interval were computed for the discontinuous patterns detected and they are in agreement with reported values.

20 June 2016 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
JWJames Wilson
James Wilson
JHJens Haueisen
Jens Haueisen
Objective: This paper presents the development of a fast and robust method which can be applied to multichannel physiologic signals for the purpose of either removing a selected interfering signal or separating signals that arise from temporally correlated and spatially distributed signals such as maternal or fetal cardiac waveform recordings. Methods: Projection operators based upon both the weighted and un-weighted minimum norm equations are presented. The weighted formulation uses models based on signal covariance and the un-weighted formulation requires that a statistical model be built using time-locked averaging. Results: We present examples that demonstrate the utility of our projection operators when applied to maternal and fetal magneto-cardiograms. In addition, we demonstrate the ability to separate fetal breathing signals from both maternal and fetal cardiac signals. Conclusion: The method is effective, robust, fast, and does not require significant input from a user. Significance: Although we demonstrate the utility of our projection operators applied to biomagnetic signals, the method can easily be adapted to other applications were the goal is to either separate or suppress selected signal components.