Christoph Arnoldner

Christoph Arnoldner

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2020 in European Journal of Pharmaceutics and Biopharmaceutics
Verified
Journal Article
Closed access
JGJulia Clara Gausterer
Julia Clara Gausterer
NSNodir Saidov
Nodir Saidov
NANavid Ahmadi
Navid Ahmadi
CZChengjing Zhu
Chengjing Zhu
MWMichael Wirth
Michael Wirth
CHClemens Honeder
Clemens Honeder

2 April 2014 in Audiology and Neurotology
Verified
Journal Article
Open access
PDF file
CHClemens Honeder
Clemens Honeder
EEElisabeth Engleder
Elisabeth Engleder
HSHanna Schöpper
Hanna Schöpper
FGFranz Gabor
Franz Gabor
GRGottfried Reznicek
Gottfried Reznicek
CAChristoph Arnoldner
Christoph Arnoldner
The pharmacokinetic properties and tolerability of a triamcinolone acetonide poloxamer 407 hydrogel for intratympanic application were investigated in a guinea pig model. Evaluation of in vivo release kinetics showed very high initial perilymph drug levels, with clinically relevant levels present for a minimum of 10 days. Assessment of auditory brainstem response thresholds showed a minimal, delayed and transient threshold shift, which was apparent on day 3 and resolved by day 10. No relevant histological changes of the middle and inner ear structures were noted, and hair cell counts showed no significant differences between treated and untreated ears. Thus, the triamcinolone-acetonide-loaded poloxamer 407 hydrogel is an effective vehicle for sustained high-dose inner ear glucocorticoid delivery.

3 October 2019 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Faris F. BrkicFaris F. Brkic
Faris F. Brkic
DRDominik Riss
Dominik Riss
KSKatharina Scheuba
Katharina Scheuba
CAChristoph Arnoldner
Christoph Arnoldner
WGWolfgang Gstöttner
Wolfgang Gstöttner
EVErich Vyskocil
Erich Vyskocil
Bone-conduction implants are a standard therapeutic option for patients with conductive, unilateral, or mixed hearing loss who either do not tolerate conventional hearing aids or can benefit from surgery. The aim of this study was to evaluate long-term medical and technical outcomes, and audiological results with the Bonebridge transcutaneous bone-conduction implant. This retrospective study included all patients implanted with a bone-conduction hearing implant at a tertiary medical referral center between March 2012 and October 2018. Medical and technical outcomes included the mean length of implant usage, medical and technical complications (skin and wound infection, lack of benefit, technical failure), explantations and revisions, coupling approaches, implant failure rate, implant survival and the implant loss for added follow-up years. Auditory results were measured by functional hearing gain and the Freiburger monosyllabic test at 65 dB sound pressure level. Sixty-four patients were included in the study; five of these were implanted bilaterally (69 devices). Five unilaterally implanted patients were lost to follow-up. The mean follow-up was 27.1 months (range: 0.2 months–6.3 years). The mean implant usage was 25.9 months (range: 0.2 months–6.3 years). Fifty-seven implants (89.1%) were in use at the end of the follow-up period. Complications occurred in six ears (9.4%). Five implants (7.8%) were explanted without reimplantation. Device failure occurred in one implant (1.6%), which was possibly caused by recurrent head trauma. The rate of implant loss due to technical device failure (damage to device) was 1 per 72 follow-up years. The mean improvement on the Freiburger monosyllabic test (52.1%, p = 0.0001), and in functional hearing gain across frequencies (26.5 dB, p = 0.0001) was significant. This single-center follow-up reveals the medical and technical reliability of a transcutaneous bone-conduction implant for hearing rehabilitation because complication and revision rates were low. The majority of patients still used the device at the end of the observation period. Implantation resulted in favorable hearing outcomes in comparison to that of unaided conditions. Cautious patient selection mainly regarding co-morbidities, the history of chronic otologic diseases and proper surgical technique seems to be crucial in reducing complications.

1 November 2016 in Hearing Research
Verified
Journal Article
Open access
CHClemens Honeder
Clemens Honeder
CZChengjing Zhu
Chengjing Zhu
HSHanna Schöpper
Hanna Schöpper
JGJulia Clara Gausterer
Julia Clara Gausterer
MWManuel Walter
Manuel Walter
CAChristoph Arnoldner
Christoph Arnoldner
It has been shown that glucocorticoids reduce the hearing threshold shifts associated with cochlear implantation. Previous studies evaluated the administration of glucocorticoids immediately before surgery or the repeated pre- or perioperative systemic application of glucocorticoids. The aim of this study was to evaluate the effects of a sustained release dexamethasone hydrogel in hearing preservation cochlear implantation. To address this issue, a guinea pig model of cochlear implantation was used. 30 normal hearing pigmented guinea pigs were randomized into a group receiving a single dose of a dexamethasone/poloxamer407 hydrogel one day prior to surgery, a second group receiving the hydrogel seven days prior to surgery and a control group. A silicone cochlear implant electrode designed for the use in guinea pigs was inserted to a depth of 5 mm through a cochleostomy. Compound action potentials of the auditory nerve (frequency range 0.5-32 kHz) were measured preoperatively, directly postoperatively and on postoperative days 3, 7, 14, 21 and 28. Following the last audiometry, temporal bones were harvested and histologically evaluated. Dexamethasone hydrogel application one day prior to surgery resulted in significantly reduced hearing threshold shifts at low, middle and high frequencies measured at postoperative day 28 (p < 0.05). Application of the hydrogel seven days prior to surgery did not show such an effect. Dexamethasone application one day prior to surgery resulted in increased outer hair cell counts in the cochlear apex and in reduced spiral ganglion cell counts in the basal and middle turn of the cochlea, a finding that was associated with a higher rate of electrode translocation in this group. In this study, we were able to demonstrate functional benefits of a single preoperative intratympanic application of a sustained release dexamethasone hydrogel in a guinea pig model of cochlear implantation.


3 July 2020 in Otology & Neurotology
Verified
Journal Article
Closed access
VDValerie Dahm
Valerie Dahm
AAAlice B. Auinger
Alice B. Auinger
CHClemens Honeder
Clemens Honeder
DRDominik Riss
Dominik Riss
LLLukas D. Landegger
Lukas D. Landegger
CAChristoph Arnoldner
Christoph Arnoldner
Objective: The aim of the study was to evaluate the predictive value regarding postoperative hearing benefit of electrically evoked auditory brainstem response audiometry in sporadic vestibular schwannoma patients undergoing simultaneous tumor resection and cochlear implantation. Design: Patients were included in a prospective study conducted between October 2016 and January 2019. Setting: The study was conducted at a tertiary care center. Participants: Subjects with unilateral sporadic vestibular schwannoma were screened for study participation. Patients underwent translabyrinthine vestibular schwannoma resection and cochlear implantation simultaneously. Intervention: Electrically evoked brainstem response audiometry was performed during surgery before and after tumor removal using an intracochlear test electrode to objectively evaluate nerve conduction. Main Outcome Measure: Electrically evoked brainstem response audiometry results were correlated with postoperative sound field audiometry, word recognition tests, and speech reception thresholds. Quality of life was assessed before and 12 months after translabyrinthine tumor removal and cochlear implantation. Results: Five patients, three male and two female, were included in the study and followed for at least 1 year after implantation. Three of the five patients are daily cochlear implant users with open set speech recognition. Two individuals with negative intraoperative electrically evoked auditory brainstem response results showed no auditory perception with cochlear implant. Conclusions: Simultaneous translabyrinthine vestibular schwannoma resection and cochlear implantation with intraoperative electrically evoked auditory brainstem response measurements is a feasible and promising option for sporadic vestibular schwannoma patients. Preservation of electrically evoked auditory brainstem responses seems to predict good subsequent hearing outcomes.