Chaofeng Li

Prof. Chaofeng Li


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2012 in Analytica Chimica Acta
Verified
Journal Article
Closed access
CLChaofeng Li
Chaofeng Li
QLQiuli Li
Qiuli Li
JGJing-Hui Guo
Jing-Hui Guo
XLXiang-Hui Li
Xiang-Hui Li
YYYue-Heng Yang
Yue-Heng Yang

1 March 2016 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
CLChaofeng Li
Chaofeng Li
XWXuan-Ce Wang
Xuan-Ce Wang
JGJing-Hui Guo
Jing-Hui Guo
ZCZhu-Yin Chu
Zhu-Yin Chu
LFLianjun Feng
Lianjun Feng
A straightforward tandem column separation procedure is presented for the separation of Sr, Nd, Pb, and Hf from silicate materials. It allows rapid purification, without any intervening evaporation, of these four elements of great interest in Earth science and cosmochemistry. After sample loading, the upper Sr Spec column adsorbs Sr and Pb, while the lower TODGA Spec column adsorbs Hf and Nd. Strontium-lead and hafnium–neodymium elements are then back-extracted from the Sr Spec and TODGA Spec columns, respectively. The whole separation procedure, including column setup, cleaning, and pre-conditioning, takes approximately eight hours for separating a batch of 25 samples. The proposed procedure offers significant improvement in separation efficiency of these often-used four elements, compared with conventional four column methods. Fractions of Sr, Nd and Pb are then measured by TIMS and the Hf fraction is determined by MC-ICP-MS. The stability of this procedure was demonstrated by replicate measurements of 87Sr/86Sr, 143Nd/144Nd, 176Hf/177Hf, 206Pb/204Pb, 207Pb/204Pb and 208Pb/204Pb isotope ratios of eight international silicate rock reference materials, spanning a wide range of bulk compositions. The analytical results obtained in this study agree well with published data. The external reproducibility (2RSD, n = 8) of standard BCR-2 was ±0.0026% for 87Sr/86Sr, ±0.0020% for 143Nd/144Nd, ±0.0049% for 176Hf/177Hf, and ±0.026–0.034% for 206Pb/204Pb, 207Pb/204Pb and 208Pb/204Pb isotope ratios.

5 May 2015 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
CLChaofeng Li
Chaofeng Li
ZCZhu-Yin Chu
Zhu-Yin Chu
JGJing-Hui Guo
Jing-Hui Guo
YLYou-Lian Li
You-Lian Li
YYYue-Heng Yang
Yue-Heng Yang
XLXiang-Hui Li
Xiang-Hui Li
Thermal ionization mass spectrometry (TIMS) is considered the most accurate technique for determining Sr–Nd–Pb isotopic ratios in geological samples. However, time-consuming and complex sample separation procedures greatly hinder the instrumental measurement efficiency. In this study, a single-column separation chemistry procedure for Sr–Nd–Pb from single rock dissolution was developed. The chemistry procedure was designed to minimize the number of evaporation steps and considerably shorten the separation time, enabling high throughput for TIMS. In contrast to conventional three-column separation procedures (∼3 days), this technique was characterized by high efficiency superiority in terms of separation time (∼8 hours), a 3-fold enhancement in the separation efficiency. The stability of our procedure was demonstrated by replicated TIMS measurements of 87Sr/86Sr, 143Nd/144Nd, 206Pb/204Pb, 207Pb/204Pb and 208Pb/204Pb ratios for six international silicate rock reference materials, spanning a wide range of bulk compositions. The analytical results obtained for these standards agreed well with published data. The external reproducibility (2 RSD, n = 10) of a BCR-2 standard sample was ±0.0020% for 87Sr/86Sr, ±0.0023% for 143Nd/144Nd, and ±0.021–0.033% for 206Pb/204Pb, 207Pb/204Pb and 208Pb/204Pb ratios.

19 July 2011 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
CLChaofeng Li
Chaofeng Li
QLQiuli Li
Qiuli Li
JGJing-Hui Guo
Jing-Hui Guo
XLXiang-Hui Li
Xiang-Hui Li
Sm–Nd isotopic system is a powerful tracer and dating tool in geochemistry and cosmochemistry. Thermal ionization mass spectrometry (TIMS) is the benchmark method for obtaining high precision Nd isotope ratios. Traditionally, a two-step separation was employed in order to obtain high purity Nd fraction, which makes the sample preparation time-consuming. In this study, we present a new method to directly obtain precise and accurate Nd isotope ratios of geological samples without Sm–Nd separation. The key point is to well correct isobaric interferences of 144Sm on 144Nd for this method. The accurate intensity of 144Sm can be obtained using 147Sm/144Sm ratio of 4.87090 and mass discrimination factor of Sm (βSm), which is achieved using 147Sm/149Sm ratio of 1.08583 with Russell equation. Consequently, the real intensity of 144Nd was achieved, then also raw 146Nd/144Nd, 143Nd/144Nd ratios. Finally, 143Nd/144Nd ratio is normalized using 146Nd/144Nd ratio of 0.7219 following exponential law. The accuracy of this method is validated by replicating TIMS measurements for thirteen international reference materials of silicate rock, spanning a wide range of Sm/Nd from 0.13 to 0.46 and bulk compositions. The measured 143Nd/144Nd ratios of the rock standards are in good agreement with the reported values of within error of ±0.004%. Our new method shortens the analytical procedure and significantly improves sample throughput which greatly contributes to those studies requiring a large dataset and quick analysis.

26 September 2019 in Minerals
Verified
Journal Article
Open access
PDF file
LWLi-Guang Wu
Li-Guang Wu
XLXian-Hua Li
Xian-Hua Li
XLXiaoxiao Ling
Xiaoxiao Ling
YYYue-Heng Yang
Yue-Heng Yang
CLChaofeng Li
Chaofeng Li
BPBenita Putlitz
Benita Putlitz
The oxygen (O) and neodymium (Nd) isotopic composition of monazite provides an ideal tracer of metamorphism and hydrothermal activity. Calibration of the matrix effect and monitoring of the external precision of monazite O–Nd isotopes with microbeam techniques, such as secondary ion mass spectrometry (SIMS) and laser ablation-multicollector-inductively coupled plasma-mass spectrometry (LA-MC-ICPMS), require well-characterized natural monazite standards for precise microbeam measurements. However, the limited number of standards available is impeding the application of monazite O–Nd isotopes. Here, we report on the RW-1 monazite as a potential new working reference material for microbeam analysis of O–Nd isotopes. Microbeam measurements by electron probe microanalysis (EPMA), SIMS, and LA-MC-ICPMS at 10–24 µm scales have confirmed that it is homogeneous in both elemental and O–Nd isotopic compositions. SIMS measurements yield δ18O values consistent, within errors, with those obtained by laser fluorination techniques. Precise analyses of Nd isotope by thermal ionization mass spectrometry (TIMS) are consistent with mean results of LA-MC-ICPMS analyses. We recommend δ18O = 6.30‰ ± 0.16‰ (2SD) and 143Nd/144Nd = 0.512282 ± 0.000011 (2SD) as being the reference values for the RW-1 monazite.

30 April 2014 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
CLChaofeng Li
Chaofeng Li
JGJing-Hui Guo
Jing-Hui Guo
YYYue-Heng Yang
Yue-Heng Yang
ZCZhu-Yin Chu
Zhu-Yin Chu
XWXuan-Ce Wang
Xuan-Ce Wang
Thermal ionization mass spectrometry and multiple-collector inductively coupled plasma mass spectrometry are considered to be “gold standards” for the determination of the isotope ratios of Sr–Nd and Hf in geological samples because of the extremely high precision and accuracy of these methods. However, the sample throughputs are hindered by time-consuming and tedious chemical procedures. Three-step ion exchange resin separation is traditionally employed to purify Sr–Nd–Hf from matrix elements. In this study, a one-step Sr–Nd–Hf separation scheme was developed to process geological samples. The separation scheme is based on the combined use of conventional AG50W-X12 cation-exchange resin and LN Spec extraction chromatographic material without any intervening evaporation step. The protocol not only prevents cross-contamination during operation using multiple-stage ion exchange resins but also significantly improves the efficiency of sample preparation. The stability of our chemical procedure was demonstrated by replicate measurements of 87Sr/86Sr, 143Nd/144Nd, and 176Hf/177Hf ratios in six international reference materials of silicate rocks. The analytical results obtained for these standard rocks compare well with the published data. The external reproducibility (2 SD, n = 10) of a BCR-2 standard sample was ±0.000018 for 87Sr/86Sr, ±0.000010 for 143Nd/144Nd, and ±0.000014 for 176Hf/177Hf.