Dayong Gao

Prof. Dr. Dayong Gao

Center for Cryo-Biomedical Engineering and Artificial Organs, Department of Mechanical Engineering, University of Washington, Seattle, WA 98195, USA

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2013 in Bone Marrow Transplantation
Verified
Journal Article
Open access
PDF file
ZSZ Shu
Z Shu
SHS Heimfeld
S Heimfeld
Dayong GaoDayong Gao
Dayong Gao
Transplantation of hematopoietic stem cells (HSCs) has been successfully developed as a part of treatment protocols for a large number of clinical indications, and cryopreservation of both autologous and allogeneic sources of HSC grafts is increasingly being used to facilitate logistical challenges in coordinating the collection, processing, preparation, quality control testing and release of the final HSC product with delivery to the patient. Direct infusion of cryopreserved cell products into patients has been associated with the development of adverse reactions, ranging from relatively mild symptoms to much more serious, life-threatening complications, including allergic/gastrointestinal/cardiovascular/neurological complications, renal/hepatic dysfunctions, and so on. In many cases, the cryoprotective agent (CPA) used—which is typically dimethyl sulfoxide (DMSO)—is believed to be the main causal agent of these adverse reactions and thus many studies recommend depletion of DMSO before cell infusion. In this paper, we will briefly review the history of HSC cryopreservation, the side effects reported after transplantation, along with advances in strategies for reducing the adverse reactions, including methods and devices for removal of DMSO. Strategies to minimize adverse effects include medication before and after transplantation, optimizing the infusion procedure, reducing the DMSO concentration or using alternative CPAs for cryopreservation and removing DMSO before infusion. For DMSO removal, besides the traditional and widely applied method of centrifugation, new approaches have been explored in the past decade, such as filtration by spinning membrane, stepwise dilution-centrifugation using rotating syringe, diffusion-based DMSO extraction in microfluidic channels, dialysis and dilution-filtration through hollow-fiber dialyzers and some instruments (CytoMate, Sepax S-100, Cobe 2991, microfluidic channels, dilution-filtration system, etc.) as well. However, challenges still remain: development of the optimal (fast, safe, simple, automated, controllable, effective and low cost) methods and devices for CPA removal with minimum cell loss and damage remains an unfilled need.

20 January 2010 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
XLXin M. Liang
Xin M. Liang
SHSangyoon J. Han
Sangyoon J. Han
JRJo-Anna Reems
Jo-Anna Reems
Dayong GaoDayong Gao
Dayong Gao
NSNathan Sniadecki
Nathan Sniadecki
Platelets play an important role in hemostasis by forming a thrombotic plug that seals the vessel wall and promotes vascular healing. After platelets adhere and aggregate at the wound site, their next step is to generate contractile forces through the coordination of physicochemical interactions between actin, myosin, and αIIbβ3 integrin receptors that retract the thrombus' size and strengthen its adhesion to the exposed matrix. Although platelet contractile forces (PCF) are a definitive feature of hemostasis and thrombosis, there are few approaches that can directly measure them. In this study, we describe the development of an approach to measure PCF in microthrombi using a microscopic flexible post force sensor array. Quasi-static measurements and live microscopic imaging of thrombin-activated platelets on the posts were conducted to assay the development of PCF to various hemostatic conditions. Microthrombi were observed to produce forces that monotonically increased with thrombin concentration and activation time, but forces subsided when thrombin was removed. PCF results were statistically similar on arrays of posts printed with fibronectin or fibrinogen. PCF measurements were combined with clot volume measurements to determine that the average force per platelet was 2.1 ± 0.1 nN after 60 min, which is significantly higher than what has been measured with previous approaches. Overall, the flexible post arrays for PCF measurements are a promising approach for evaluating platelet functionality, platelet physiology and pathology, the impacts of different matrices or agonists on hemostatic responses, and in providing critical information regarding platelet activity that can guide new hemostatic or thrombotic strategies.

1 April 2016 in Cryobiology
Verified
Journal Article
Open access
ZSZhiquan Shu
Zhiquan Shu
SHSean M. Hughes
Sean M. Hughes
CFCifeng Fang
Cifeng Fang
JHJinghua Huang
Jinghua Huang
BFBaiwen Fu
Baiwen Fu
Dayong GaoDayong Gao
Dayong Gao
Cryopreservation of specimens taken from the genital tract of women is important for studying mucosal immunity during HIV prevention trials. However, it is unclear whether the current, empirically developed cryopreservation procedures for peripheral blood cells are also ideal for genital specimens. The optimal cryopreservation protocol depends on the cryobiological features of the cells. Thus, we obtained tissue specimens from vaginal repair surgeries, isolated and flow cytometry-purified immune cells, and determined fundamental cryobiological characteristics of vaginal CD3(+) T cells and CD14(+) macrophages using a microfluidic device. The osmotically inactive volumes of the two cell types (Vb) were determined relative to the initial cell volume (V0) by exposing the cells to hypotonic and hypertonic saline solutions, evaluating the equilibrium volume, and applying the Boyle van't Hoff relationship. The cell membrane permeability to water (Lp) and to four different cryoprotective agent (CPA) solutions (Ps) at room temperature were also measured. Results indicated Vb values of 0.516 V0 and 0.457 V0 for mucosal T cells and macrophages, respectively. Lp values at room temperature were 0.196 and 0.295 μm/min/atm for T cells and macrophages, respectively. Both cell types had high Ps values for the three CPAs, dimethyl sulfoxide (DMSO), propylene glycol (PG) and ethylene glycol (EG) (minimum of 0.418 × 10(-3) cm/min), but transport of the fourth CPA, glycerol, occurred 50-150 times more slowly. Thus, DMSO, PG, and EG are better options than glycerol in avoiding severe cell volume excursion and osmotic injury during CPA addition and removal for cryopreservation of human vaginal immune cells.

1 April 2014 in Cryobiology
Verified
Journal Article
Closed access
Tao WangTao Wang
Tao Wang
Gang ZhaoGang Zhao
Gang Zhao
XLXin M. Liang
Xin M. Liang
YXYunpeng Xu
Yunpeng Xu
YLYang Li
Yang Li
Dayong GaoDayong Gao
Dayong Gao

6 February 2017 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
CFCifeng Fang
Cifeng Fang
FJFujun Ji
Fujun Ji
ZSZhiquan Shu
Zhiquan Shu
Dayong GaoDayong Gao
Dayong Gao
We developed an integrated microfluidic platform for instantaneous flow and localized temperature control. The platform consisted of a flow-focusing region for sample delivery and a cross-junction region embedded with a microheater for cell trapping and localized temperature control by using an active feedback control system. We further used it to measure the membrane transport properties of Jurkat cells, including the osmotically inactive cell volume (Vb) and cell membrane permeabilities to water (Lp) and to cryoprotective agent (CPA) solutions (dimethyl sulfoxide (DMSO) in this study) (PS) at various temperatures (room temperature, 30 °C, and 37 °C). Such characteristics of cells are of great importance in many applications, especially in optimal cryopreservation. With the results, the corresponding activation energy for water and CPA transport was calculated. The comparison of the results from the current study with reference data indicates that the developed platform is a reliable tool for temperature-dependent cell behavior study, which provides valuable tools for general cell manipulation applications with precise temperature control.

25 November 2015 in Advanced Healthcare Materials
Verified
Journal Article
Closed access
PDF file
WCWanyu Chen
Wanyu Chen
ZSZhiquan Shu
Zhiquan Shu
Dayong GaoDayong Gao
Dayong Gao
ASAmy Shen
Amy Shen