Jingying Wang

Dr. Jingying Wang

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2019 in Applied Acoustics
Verified
Journal Article
Closed access
CGChang Guo
Chang Guo
Ming GaoMing Gao
Ming Gao
Jingying WangJingying Wang
Jingying Wang
YSYuetao Shi
Yuetao Shi
SHSuoying He
Suoying He

14 March 2018 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
YZYue Zhou
Yue Zhou
CLChunhian Lee
Chunhian Lee
Jingying WangJingying Wang
Jingying Wang
Arterial stenosis plays an important role in the progressions of thrombosis and stroke. In the present study, a standard axisymmetric tube model of the stenotic artery is introduced and the degree of stenosis η is evaluated by the area ratio of the blockage to the normal vessel. A normal case (η=0) and four stenotic cases of η=0.25, 0.5, 0.625, and 0.75 with a constant Reynolds number of 300 are simulated by computational fluid dynamics (CFD), respectively, with the Newtonian and Carreau models for comparison. Results show that for both models, the poststenotic separation vortex length increases exponentially with the growth of stenosis degree. However, the vortex length of the Carreau model is shorter than that of the Newtonian model. The artery narrowing accelerates blood flow, which causes high blood pressure and wall shear stress (WSS). The pressure drop of the η=0.75 case is nearly 8 times that of the normal value, while the WSS peak at the stenosis region of η=0.75 case even reaches up to 15 times that of the normal value. The present conclusions are of generality and contribute to the understanding of the dynamic mechanisms of artery stenosis diseases.

21 November 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CGChang Guo
Chang Guo
Jingying WangJingying Wang
Jingying Wang
Ming GaoMing Gao
Ming Gao
The acoustic field distribution and evolution characteristics in a time domain inside a centrifugal pump are studied. During the fluid motion process, the acoustic source and acoustic pressure are basically less than 0, and the minimum value of the two parameters is distributed near the tongue. Additionally, the concentration, break, extend, migration and reaggregation phenomena of the minimum acoustic source region exist. Specifically, as the blade passes through the tongue, the minimum acoustic source region concentrates on the tongue firstly, then extends and migrates downstream slightly with the blade motion, and aggregates again around the tongue, which results in the similar evolution characteristics of acoustic pressure. Moreover, the standard deviation (STD) of acoustic source mainly focuses near the pressure side of blade tail and volute tongue, and the maximum STD is located at the tongue. Compared with the source component induced by stretching of the vortex, the source component induced by non-uniformity of fluid kinetic energy is closer to the overall acoustic source. Take the tongue as an example, at various rotational speeds, the STD proportions of the two components are about 5% and 95%, respectively. This study discusses the generation, distribution and evolution characteristics of acoustic field, which lays a foundation to analyze the acoustic field propagation mechanism of centrifugal pumps.

4 September 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WZwei zhao
wei zhao
XYXinglian Yang
Xinglian Yang
Jingying WangJingying Wang
Jingying Wang
YZYongkang Zheng
Yongkang Zheng
YZYue Zhou
Yue Zhou
Significant thermochemical nonequilibrium effects always exist in the flow field around hypersonic vehicle at extreme flight condition. Previous studies have proposed various thermodynamic and chemical kinetic models to describe the thermochemical nonequilibrium processes in hypersonic and high-temperature flow. However, different selections from such models might lead to remarkable variations in computational burden and prediction accuracy, which is still a matter of being unclear. In the present study, different commonly studied models for calculating the thermochemical nonequilibrium are systematically evaluated. The 5-, 7- and 11-species chemical kinetic models of Dunn-Kang, Gupta and Park together with the one- and two-temperature models are employed respectively to simulate the hypersonic flows over a standard cylinder with the radius of 1 m by HyFLOW, which is a commercial software based on the numerical solution of Navier-Stokes equations. Three flight conditions of FIRE Ⅱ classical flight trajectory are employed in the study. It shows that the differences between the results of the Dunn-Kang, Gupta and Park chemical kinetic models with the same number of species are small, but the Gupta model predicts the most conservative values of the wall heat flux. When only the order of magnitude and distribution trends of the pressure and wall heat flux are concerned, the one-temperature model combined with 5-species chemical reaction model can be used for a rapid prediction. While the accurate flow solution is required, the two-temperature model conjugated with Gupta 11-species model is recommended, especially at the conditions of extremely high altitude and Mach number.

10 October 2022 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
MLMingrui Li
Mingrui Li
Jingying WangJingying Wang
Jingying Wang
WHWen Huang
Wen Huang
YZYue Zhou
Yue Zhou
XSXue Song
Xue Song
Inferior vena cava (IVC) filters are used to prevent pulmonary embolism in patients with deep vein thrombosis for whom anticoagulation is unresponsive. The head is a necessary structure for an Inferior vena cava filter (IVCF) in clinic use. At present, there are various head configurations for IVCFs. However, the effect of head pattern on the hemodynamics of IVCF is still a matter of unclear. In this study, computational fluid dynamics is used to simulate non-Newtonian blood flows around four IVCFs with different heads inside an IVC model, in which the Denali filter with a solid and hooked head is employed as a prototype, and three virtual variants are reconstructed either with a no-hook head or with a through-hole head for comparison. The simulation results show that the through-hole head can effectively avoid the recirculation region and weaken the blood flow stasis closely downstream the IVCF head. The shape change of the filter head has no significant effect on the blood flow acceleration inside the IVCF cone as well as little influence on the wall shear stress (WSS) distribution on the filter wire surface and IVC wall. The structure pattern of filter head greatly affects the flow resistance of its own. However, the flow drag of filter head only occupies a small proportion of the total resistance of IVCF. Therefore, to reduce the flow resistance of an IVCF should optimize its whole structure.

1 May 2021 in Journal of Biomechanics
Verified
Journal Article
Closed access
SCShuai Chen
Shuai Chen
Jingying WangJingying Wang
Jingying Wang
DLDongxu Liu
Dongxu Liu
LLLi Lei
Li Lei
WWWei Wu
Wei Wu
CLChunhian Lee
Chunhian Lee