The vibrations of microcantilevers in atomic force microscopes (AFMs) or radio frequency (RF) switches are strongly influenced by the viscous hydrodynamics of the surrounding fluid in the vicinity of a rigid wall. While prior efforts to model this hydrodynamic loading have focused on squeeze film damping effects at high Knudsen and squeeze numbers, the regimes of low Knudsen and squeeze numbers are also very important for which squeeze film models need to be discarded in favor of unsteady Stokes hydrodynamics. We extend the work of Green and Sader [Phys Fluids 17, 073102 (2005); J. Appl. Phys. 98, 114913 (2005)] and present compact semianalytical formulas for the unsteady viscous hydrodynamic function of slender microbeams oscillating near rigid walls, in terms of key nondimensional numbers. Using these closed-form expressions, it becomes possible to predict easily the wet natural frequencies and quality factors of multiple modes of microcantilevers near rigid walls in diverse applications ranging from AFM in liquids to RF microswitches under ambient conditions. The semianalytical formulas are extensively validated by comparing their predicted wet natural frequencies and quality factors with those based on three-dimensional, transient flow-structure interaction simulations, as well as previous experiments performed in the field by other researchers.
We investigate the mechanical properties of cantilevered silver-gallium (Ag(2)Ga) nanowires using laser Doppler vibrometry. From measurements of the resonant frequencies and associated operating deflection shapes, we demonstrate that these Ag(2)Ga nanowires behave as ideal Euler-Bernoulli beams. Furthermore, radial asymmetries in these nanowires are detected through high resolution measurements of the vibration spectra. These crystalline nanowires possess many ideal characteristics for nanoscale force and mass sensing, including small spring constants (as low as 10(-4) N m(-1)), high frequency bandwidth with resonance frequencies in the 0.02-10 MHz range, small suspended mass (picograms), and relatively high Q-factors (approximately 2-50) under ambient conditions. We evaluate the utility of Ag(2)Ga nanowires for nanocantilever applications, including ultrasmall mass and high frequency bandwidth piconewton force detection.
The time response of tuning-fork based sensors can be improved by operating them at higher eigenmodes because a measurement takes at least one oscillation cycle in dynamic force microscopy and the oscillation period of the second eigenmode is only about one sixth of the fundamental mode. Here we study the higher-order eigenmodes of quartz qPlus sensors [Bettac et al., Nanotechnology 20, 264009 (2009); Giessibl and Reichling, Nanotechnology 16, S118 (2005); Giessibl, Appl. Phys. Lett. 76, 1470 (2000); and Giessibl, Appl. Phys. Lett. 73, 3956 (1998)], their equivalent stiffness, and piezoelectric sensitivity, while paying special attention to the influence of the mass and rotary inertia of the sensing tip which is attached to the end of the qPlus quartz cantilever. A combination of theoretical modeling and scanning laser Doppler vibrometry is used to study the eigenmodes of qPlus sensors with tungsten tips. We find that the geometry of tungsten tips can greatly influence the shape, equivalent stiffness, and piezoelectric sensitivity of the second eigenmode of the quartz cantilever. At a critical tip length it is possible to theoretically achieve infinite equivalent stiffness and infinite piezoelectric sensitivity when the tip becomes a perfect node of vibration and beyond this critical tip length the second eigenmode loses its vibration node and the trajectory of the tip reverses with respect to the beam curvature. The findings have major implications for optimizing tip geometry for high-resolution imaging with qPlus sensors using higher eigenmodes.
24 September 2009 in Journal of Micromechanics and Microengineering
Laser Doppler vibrometry is used to measure the thermal vibration spectra of individual multiwalled carbon nanotubes (MWNTs) under ambient conditions. Since the entire vibration spectrum is measured with high frequency resolution, the resonant frequencies and quality factors of the MWNTs are accurately determined, allowing for estimates of their elastic moduli. Because the diameters of the MWNTs studied are smaller than the wavelength of the vibrometer's laser, Mie scattering is used to estimate values for the smallest diameter nanotube or nanowire whose vibration can be measured in this way.