Electric drives immune to failures of selected elements of the power system or measuring sensors have been the subject of research in recent years, due to the growing interest in systems with an increased level of safety. This article concerns the analysis of the direct field-oriented control induction motor drive after the failure of all stator current sensors. An adaptive virtual current sensor (AVCS) was used to estimate the stator current, based on the measurement of the motor angular velocity and the voltage in the $\text{DC}\ (u_{\text{DC}})$ of the voltage-source inverter. This article presents the possibility of improving the accuracy of stator current estimation using the original approximation of changes in rotor resistance depending on the drive operating point when the measurement information about the stator current has been lost. This approximation was determined experimentally during the normal operation of the drive using a rotor resistance estimator. The determined approximate lookup functions were used to adapt the rotor resistance in the AVCS during the drive system operation in a postfault mode. This approach has made it possible to significantly improve the accuracy of the stator current reconstruction, especially under low speeds and load torques, which was demonstrated in experimental studies .
Designing electrical drives resistant to the failures of chosen sensors has recently become increasingly popular due to the possibility of their use in fault-tolerant control (FTC) systems including drives for electric vehicles. In this article, a virtual current sensor (VCS) based on an algorithmic method for the reconstruction of the induction motor (IM) phase currents after current sensor faults was proposed. This stator current estimator is based only on the measurements of the DC-bus voltage in the intermediate circuit of the voltage-source inverter (VSI) and a rotor speed. This proposal is dedicated to fault-tolerant vector controlled IM drives, where it is necessary to switch to scalar control as a result of damage to the current sensors. The proposed VCS allows further uninterrupted operation of the direct rotor-field oriented control (DRFOC) of the induction motor drive. The stator current estimator has been presented in the form of equations, enabling its practical implementation in a microprocessor system. Simulation studies of the proposed algorithm in an open and closed-loop DRFOC structure are presented under different operation conditions of the drive system. The experimental verification of the proposed method is also presented and the accuracy of the stator current estimation algorithm is analyzed under various operating conditions of the drive system.
In the modern induction motor (IM) drive system, the fault-tolerant control (FTC) solution is becoming more and more popular. This approach significantly increases the security of the system. To choose the best control strategy, fault detection (FD) and fault classification (FC) methods are required. Current sensors (CS) are one of the measuring devices that can be damaged, which in the case of the drive system with IM precludes the correct operation of vector control structures. Due to the need to ensure current feedback and the operation of flux estimators, it is necessary to immediately compensate for the detected damage and classify its type. In the case of the IM drives, there are individual suggestions regarding methods of classifying the type of CS damage during drive operation. This article proposes the use of the classical multilayer perceptron (MLP) neural network to implement the CS neural fault classifier. The online work of this classifier was coordinated with the active FTC structure, which contained an algorithm for the detection and compensation of failure of one of the two CSs used in the rotor field-oriented control (DRFOC) structure. This article describes this structure and the method of designing the neural fault classifier (NN-FC). The operation of the NN-FC was verified by simulation tests of the drive system with an integrated FTC strategy. These tests showed the high efficiency of the developed fault classifier operating in the post-fault mode after compensating the previously detected CS fault and ensuring uninterrupted operation of the drive system.
Fault-tolerant control (FTC) solutions are increasingly being used in modern drive systems with AC motors. Such systems provide a higher degree of security and solutions that allow the on-line detection and localization of failures, as well as the switching of the control mode to a mode that allows us to continue the operation or safely stop the drive system. As the current sensors (CSs) are necessary to ensure precise control of the AC motors, in the event of their failure, one of two strategies can be used—hardware or software redundancy. The first strategy requires the use of additional measuring sensors. For this reason, the algorithmic solution, based on the Luenberger Observer (LO), has been proposed in this article as one of the software redundancy methods. In contrast to methods presented in the literature, the proposed solution allows one not only to compensate the stator current in a phase with a faulty CS, but also to adjust the correction of current estimation based on a measured signal in the other phase with a healthy CS. Extensive simulation studies in the direct rotor flux-oriented control (DRFOC) structure with the induction motor (IM) confirm the effectiveness of the proposed method. In addition, the proposed solution allows the drive system to be controlled even if all CSs are damaged.
In electric drive systems, one of the most common faults is related to measurement equipment, including current sensors (CSs). As information about the stator current is crucial to ensure precise control of AC drives, such a fault significantly affects the quality and security of the entire system. For this reason, a modified extended Kalman filter (EKF) has been presented in this paper as an algorithmic solution to restore stator current in the event of CS failure. In order to minimize the impact of rotor and stator resistance variations on the quality of the estimation, the proposed model includes an estimation of the general coefficient of their changes. In contrast to solutions known in the literature, the presented model considers changes in both resistances in the form of a single coefficient. This approach allows us to maintain a low order of the estimator (fifth) and thus minimize the tendency to system instability and decrease computation burden. Extensive simulation tests have shown a significant improvement in the accuracy of stator current estimation under both motor and regenerating modes, a wide speed range (1–100%), and changes in motor parameters.
In modern systems with induction motors (IM), in addition to precision, it is also very important to ensure the highest possible reliability and safety. To ensure the above, information about the stator current value is required. If the current sensor (CS) fails, a redundant sensor or an algorithmic solution can be used. The Luenberger observer (LO) can be used to estimate the lost stator current without increasing the cost of the drive system. However, this solution is based on the mathematical model of IM, which is sensitive to its parameters. Therefore, this paper presents a modified LO (MLO) and investigates the effect of a coefficient in the error gain matrix on improving robustness to changes in the IM parameters. As shown by extensive studies, the proposed solution has significantly reduced the influence of the IM parameters on the accuracy of the stator current estimation, which has not been previously reported in the known literature.